xerox 6679 service manual54
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:xerox 6679 service manual54.pdf
Size: 2854 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 23 May 2019, 16:53 PM
Rating: 4.6/5 from 642 votes.
Status: AVAILABLE
Last checked: 11 Minutes ago!
In order to read or download xerox 6679 service manual54 ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
xerox 6679 service manual54Install screw anchors if attaching to drywall or masonry wall. Attach a separate control wire to the remaining master valve installed in your irrigation system. A solenoid wire. A pump start relay is electrical interference. The purpose of this sensor deactivated automatic watering, the is to stop automatic watering when weather conditions dictate. Adjust Sync systems. Solar Sync is a sensor system that will automatically the Region as needed by using the buttons. You can use methods A, B or C to help you choose which region is For accurate Solar Sync measurements, the controller needs to best for your area: be programmed for the average peak season ET for your region. The display changes when the dial is rotated to indicate the symbol or character is flashing will be the item specific programming information to enter. You can switch to cycles. Start times may be entered in any order. The X-Core another program by pressing the button.This feature instead of specific days of the week (odd days: 1st, 3rd, 5th, etc.; is useful to inhibit watering on specific day(s). For example, if you even days: 2nd, 4th, 6th, etc.). Adjustment value can be adjusted as described. 3. Turn the dial back to the RUN position at. Press the button to scroll nated station will water, then the MANUAL-ONE STATION through the stations and use the button to adjust station. For example, test program. To access other stations, press into more usable, shorter watering durations. This feature is useful button. Once the desired Cycle times for each station have been pro- The user can set the Soak time from 1 minute to 4 hours grammed, the Cycle time can be accessed by pressing the in 1 - minute increments. This product should only be serviced by trained and authorized personnel. Install screw anchors if attaching to drywall or masonry wall. CaUTIoN: RIsk OF eXPLOsIOn IF BAtteRy Is RePLACeD By An InCORReCt tyPe. DIsPOse OF UseD BAtteRIes ACCORDInG tO tHe InstRUCtIOns.http://ac-kenigsberg.ru/files/file/c-5050-manual.xml
- Tags:
- xerox 6679 service manual54.
Attach a separate control wire to the remaining master valve installed in your irrigation system. A solenoid wire. A pump start relay is a device that uses a signal from the controller to actuate a separate electrical circuit to energize a pump to provide water to your system. The purpose of this sensor deactivated automatic watering, is to stop automatic watering when weather conditions dictate. Use the button to advance to the adjust the X-Core controller’s watering schedule (based on. You can use methods A, B or C to help you choose which region is For accurate Solar Sync measurements, the controller needs to best for your area: be programmed for the average peak season ET for your region. The display changes when the dial is rotated to indicate the symbol or character is flashing will be the item specific programming information to enter. You can switch to start times may be entered in any order.WATER DAYS will automatically sort them. MO), press the button to activate 1. This feature Valves currently watering will be shut off after SYSTEM OFF is useful to inhibit watering on specific day(s). For example, if you. To use the Seasonal Adjustment value can be adjusted as described. You can also activate all stations to water without using the dial. 2. Station run time will flash in 1. For example, test program. This product should only be serviced by trained and authorized personnel. All necessary hardware is included for most installations. NOTE: The indoor Pro-C is not weather or water resistant, and must be installed indoors or in a protected area. This device is not intended for use by young children. NOTE: It is recommended that a licensed 2. At valves, attach a common wire to either solenoid wire of all valves.The battery allows the user to program the controller without AC power. Watering will not occur without AC power.http://www.tis.az/userfiles/c-172n-manual.xml Since this controller has non-volatile memory, the program clock and calendar will be retained during a power outage even if no battery is installed. When a pump is to be operated by the controller, a pump start relay is typically used. Hunter offers a full range a pump start relays for most applications. PSR Series. ConneCTInG To THe HUnTer eT sYsTeM ET SENSOR The Hunter ET System allows irrigation programs to be created automatically, based on local climate conditions. These programs are then loaded into the controller and run automatically. ET System uses a sensor to determine the local “evapotranspiration”. Scheduling of days to water, automatic controllers in the Hunter line-up, from the SRC to the Pro-C to run times, start times, cycle and soak operations, and more can now the ICC. Each valve is connected via wire to the There are three main components that are involved with all automatic controller. Here the wire is connected to a number that corresponds to sprinkler systems that are made today. There are some guidelines that should be followed when determining NOTE: It is usually good to water one or two hours when and how long to water. These factors are the soil type, the part before sunrise. Setting Program Start Times NOTE: If a program has all four start times turned 1. Turn the dial to the SET off, then that program is off (all other program PROGRAM START TIMES details are retained). Because there are no start position. Selecting Specific Days of the Week to Water Selecting Interval Watering 1. Press the button to activate a particular day of the week to water This feature is convenient if you want to (the display always starts with Monday). Press the button to have a more consistent watering schedule cancel watering for that day. Seasonal Adjustment After programming is complete, turn the dial to Seasonal Adjust is used to make RUN to enable automatic execution of all selected global run time changes without programs and start times.http://superbia.lgbt/flotaganis/1649479162One Touch Manual Start and Advance You can also activate a program to water without using the dial. 1. Hold down the button for 2 seconds. 2. This feature automatically defaults to program A. You can select program B, or C by pressing program. The insert a delay between when Pro-C can be customized to display only the required programs. Programable Sensor Override When the Pro-C receives an input from the sensor to disable watering, the display will indicate those The Pro-C allows the user to program the controller so that the sensor stations that have been programmed to override disables watering on only desired stations. After the Hunter Quick Check completes running this circuit diagnostic procedure, the controller returns to. Only one start time per active program is ously waters, even when it should not be required. Refer to “Setting Program Start on (cycling repeatedly). The rain sensor is interrupting irrigation or Slide the Rain Sensor switch on front panel the sensor jumper is not installed.Pull the riser up to gain access to the Socket nozzle socket. Precip Inlet Precip. Precip. Rubber cover Inlet Radius Flow Nozzle Radius Flow Flow. ACC is also prewired to accept Hunter wireless remote controls. The green, or green-and-yellow safety ground Supply wires must be 14 AWG (2 mm) or larger.Location Requirement: A) a switch or circuit-breaker 3. Level the mounting bolts before the concrete sets.Put a washer and nut on each long concrete base.VAC or 230 VAC power. Connect the incoming black (or “hot”) wire to the Red wire Supply wires must be 14AWG (2 mm) or larger. This earth ground connection is isolated from the primary AC power and is used to ground incoming surges from the communications and output valve wires. ACC expands in 6-station increments with intelligent output modules, requiring no tools to install and only a screwdriver for station wiring connections.https://gruposolux.com/images/brother-fax-575-fax-copier-manual.pdf The base configuration is 12 stations (two 6-station modules installed) with a maximum station capacity in a metal wall cabinet of 42 stations (7 total output modules x 6 stations each). ACC can be expanded at any time with either of the following types of modules: 1. Once the output module is installed in the slot, the station numbers assigned to the output module appear in the upper deck label above each slot. Connections for Hunter ET Sensor only. If upper ET terminal is colored red, Master Module requires update for use with ET. 8. If Master Module has a sticker that says “ET Ready,” or if the version number of the module is 4.0 or later, the. ConneCTInG a raIn or freeze shuT off deVICe. Up to 4 Hunter sensors can be connected to the ACC Hunter Clik sensors are usually normally closed, and open controller, including: on alarm. Programming and Operations. ConneCTInG The hunTer floW sensor.The HFS is the primary flow meter for which ACC flow functions have been designed. Additional types of flow sensor connections may also be possible. To connect: remove the weather-resistant rubber cover (metal cabinet versions), align the remote receiver’s pins with the mating receptacle, and push firmly until the receiver is fully seated. If a program ConneCTInG To Imms.hunTer IrrIGaTIon manaGemenT and monITorInG sysTem ACC controllers can upgraded to provide full two-way DIAl-uP telePhOne (ACC-COM-POtS) communications with central control software (IMMS 2.0). This is all that Off after the last “real” station has run.ACC will test actually starts stations, and this will cause water automatically in any dial position except actual watering in a fully installed system. Overlapping programs may overdrive the hydraulics of your system. Overdriving your hydraulics will damage the components and result in inferior sprinkler performance. More advanced programming overlap options are available by turning the dial to the SET PROGRAM OVERLAP OPTIONS dial position.https://schreinerheusi.de/wp-content/plugins/formcraft/file-upload/server/content/files/1628b36bb2c324---canon-powershot-a85-owners-manual.pdf The actual run time is the duration the station will water. Turn the dial to the SET STATION RUN TIMES position. Using the Global Setting 1. An “N” will appear, to show that day is never able to water, regardless of the schedule. The installation of the optional Hunter Flow Sensor (HFS) or a Data Industrial flow sensor is required for this feature to function. The ACC must first learn the normal flow, by station, for flow sensing to operate correctly. When a station with no learned flow is running, flow monitoring is temporarily disabled. The actual flow may still be viewed, even if all stations have been set to Not Monitored. Station level alarm diagnostics would not be available, but the flow will be visible. Each station may must exceed the flow by 15 before it will be treated take from 35 seconds to 5 minutes to be learned, as an alarm (to prevent false alarms due to normal flow depending on stability of the flow. This will clear the Attention, Flow that had been running (if applicable). If a station that has learned flow is activated for test purposes without turning on an actual valve, an Underflow alarm may occur. A Program cannot be both Paused and Suspended at the same time. If a Pause response is set for Program A to Sensor 2, then Pause is the only response that can be set for Program A. A sensor is Sensor alarms have no effect on Custom Manual active for this program.”. The ET Sensor is a sensor platform, and three of its individual sensors can be used as sensor inputs for alarm purposed to the ACC Controller.The ET Sensors will then function exactly like “Clik” Sensor inputs. They may have Suspend or Pause responses set by Program. Assigning ACC Sensor 1-4 alarm functions to an ET Sensor is done without connecting any additional wires. There are three program overlap options. These options allow you to maximize the number of stations operating simultaneously, if the system’s hydraulics can support the flow. To program the Program Overlap option: 1.http://basumati.com/app/webroot/ckfinder/userfiles/files/canon-sd890-is-manual.pdf Turn the dial to the SET PROGRAM OVERLAP OPTIONS position 2. It may include alarm events if applicable. A complete list of possible Station Log messages appears near the end of this manual. Alarm log items labeled “Missed Irrigation”. Check that all station module contacts are in good order and that the modules are fully inserted. Make sure powerlock tabs on front of modules have good contact with the slide lock. ET followed by a sensor name means the input has been assigned to an ET Sensor. ET Functions are described in their own section in this manual. The underflow amount cannot be set directly, alarm individually. Each of these suspect stations has its but is twice the percentage of the Limit amount set for flow sampled alone, to see if it caused the overflow. This can be used to protect high traffic areas from accidental programming, or the results of Seasonal Adjust, during busy times of day. Use the left and right arrows to move through the hour, minutes, and seconds fields until the delay is set. Hunter HFS flow sensors.Most other brands of flow sensor require two settings for calibration, the K-factor and the Offset. The correct settings for these values are found in the sensor manufacturer’s documentation, and they are based on the pipe type and size. DELETING AN SSG Technically SSGs are never deleted, as there are always 20 available.Instead, simply select the unwanted SSG, and delete the stations contained in it until no stations are listed under the SSG name. If you want the stations or SSGs to use their normal Cycle Press the INFORMATION button and turn the dial to and Soak settings (if applicable), leave the option set to Manual Operation. The by the controller.Reset should only be performed if: a) a “clean start” is desired for programming purposes, or b) if directed to do so by Hunter Technical Services as a troubleshooting technique. The Blank (Off): Normal.Use the down arrow button to select Decoder Functions.http://sciencevier.com/wp-content/plugins/formcraft/file-upload/server/content/files/1628b36c05dd6f---Canon-powershot-a85-user-manual.pdfOnly one sensor can be connected to the ET terminals. This can help you predict how controller, allow the system to operate for 3 days to gather much more or less watering will occur, as a result of sun and temperature data. Each log will show the date and time, and the Before and After settings for Seasonal Adjustment. When ACC is in a computer central control system, it can be used to report ET from a Hunter ET Sensor to the central After each ET function, it is possible to press the Back computer via IMMS control software. NO will hide all ET functions and the daily ET will not Readings can be updated at any time, by performing a new be read or displayed, and no ET will be available for the. If this is not acceptable, a Set Sensor Operation dial position (without holding separate sensor (such as Rain-Clik or Freeze-Clik) should Information). At this location, choose the Suspend or be installed and wired directly to one of the Sen 1-4 inputs Pause responses for each ET Sensor by program for instant shutdowns. Event mode allows the controller to run individual station events which have been created for it by golf control software. Delete Events: This will permanently delete all downloaded Then press the right arrow button to view the downloaded System Events. The controller will not be able to irrigate events for that day. It is designed for use with a Hunter RAD3 separately) with antenna for wireless communications, UHF radio, which must be ordered separately. CommunICaTIon module InsTallaTIon for Wall mounT ConTroller. TRNR) as a remote control for the controller. The ping test allows any controller to exchange MOD: Shows dial-up or cellular modem activity.RAD: Shows T when the controller radio is transmitting, Select a Target controller from the Source controller.Alarm Log, Missed Irrigation “Mode” Labels The controller has 3 separate log files.https://www.zulfugar.nl/wp-content/plugins/formcraft/file-upload/server/content/files/1628b36d2adf03---canon-powershot-a85-digital-camera-manual.pdf Mode appears when a station failed to complete irrigation Each individual log has the date and time of the event at for some reason, and indicates why the station was the top of the screen. Unknown No reason specified Message Description Overflow Overflow alarm occurred EASY RETRIEVE Easy retrieve programs Underflow Underflow alarm occurred. IRRIGATION STOPPED BY Irrigation was stopped by MAINT RADIO maintenance radio The Mode labels are the same as shown in the Run dial PAUSE MODE SET BY Pause Mode set by position, when stations are running. Battery, facepack: 9 VDC alkaline, for facepack remote power only. Front Faceplate 571500 Face Pack (ACC) Front Face Pack (AGC) 571505 Front Face Pack 620000 Door only Plastic Ped Com and Radio APPBRKT Bracket, including Ribbon Cable Frame Adapter 145500 Lid including Lock 553305 Lid Antenna for Ped,. Hunter I-CORE series controllers and provides two-wire decoder The I-CORE will apply power to the module and recognize it outputs for the Hunter DUAL family of field decoders.Hunter provides two types of wire for use with it is in the installer’s best interest to share what Hunter has I-CORE DUAL decoder systems. NoTE: if decoder(s) have not been installed on the two-wire path(s), the decoder output Route the red and blue wire paths from the field up through module will display “Line open”.Insert the stripped end of the red wire from a DUAL decoder Program the station number(s) into the decoders, and then write into one of the two Programming Ports to the right of the the station number assignments on the label on the decoders. The display will indicate when programming has been module has completed identification of the decoder.Conduct the programming procedure outlined above to reprogram the decoder. Select the location for the DUAL-S surge arrestor. Surround plate evenly with PowerSet material.BARTONSTEEL.COM/tony/barton/ckfinder/userfiles/files/canon-sd880-is-user-manual.pdf Basically, two functions are available to the the solenoid of a single station in a mode the produces a user in the Diagnostic mode: “chattering”. If there is no station number, This Hunter product allows wireless connection troubleshoot the two-wire path connections.If the Line Fault message only appears when a station is turned on, the problem is most likely a short in the decoder-to-solenoid wiring for the affected stations. Verify that slide lock is in the Power On position and that The DUAL48M display will show the station number when it is power is on to the DUAL48M module (display appears). Special Notes: ICore Decoders are not compatible with mechanical relays. When combining DUAL48M with conventional ICore station output modules, not all stations will be available for decoder addressing. Versatility is what makes the I-Core one of Hunter’s highest performing irrigation controllers.The user may also program the controller without AC power.The I-Core can operate with either 120VAC or 230VAC power. Supply wires must be 14AWG or larger. Turn AC power off at the source, and verify that it is off. Remove the cover from the junction box. Additional station modules may be Open the inner facepack door and locate the Slide Lock. Move the added in six station increments to expand the controller’s station capability. Hunter AC solenoids simultaneously. Route valve wires between Master Valve or Pump Start Relay location Route valve wires between control valve location and the controller. The Solar Sync incorporates a solar and temperature sensor to determine evapotranspiration, also known as ET. However, some non-Hunter flow sensors can be used. To connect a Hunter HFS Flow Sensor, route the pair of 18 AWG (1 mm) wires from the sensor into the cabinet (max distance of 1,000 ft.). The 9-volt battery is required for programming of the controller in the absense of AC power. Both the 9-volt battery and lithium battery (if a 9-volt battery is not installed), will maintain the current time and day during power outages. The I-Core controller has the ability to operate five Hunter valves at one time, and, therefore, allows for more than one program to run at the same time. This provides for the maximum amount of water saving while promoting healthy plant material. You The Solar Sync will take over and the percentage will change according to the findings of the Solar Sync sensor. If you set seasonal adjust mode to may select a maximum Cycle time of up to 60 minutes. To initiate multiple events, you. Again, will display no flow station, as well as no runtime even if there is a run the controller will go into its diagnostic flow testing for that particular station. It is important to program the correct flow sensor size. During system operation, if the station flow exceeds the Overflow limit, the controller will shut the system down and begin diagnostic testing. This is very helpful on systems with slow closing valves, or on pump systems that are operating near maximum flow or have slow well recovery. There are four basic ET regions, each with descriptions of the region, along with typical ET and temperature characteristics.If station run times were not programmed in the set Version I-Core) can be selected as a flow sensor type. After the Start Delay display will still indicate that it is Isolating the Flow Alarm). After the Start elapses for the flow monitored station, if the controller detects overflow, Up delay has elapsed, if the station flow resembles the learned flow, the it will initiate a diagnostic testing procedure. Instead of having to physically check each field wiring circuit for potential problems, the user can run the Hunter Quick Check circuit test procedure. Check AC power to controller. Fix power supply. 14-Pin connector is not fully connected. Connect ribbon cable on back of facepack door. Module locking bar is in the Power Off Slide the module locking bar into the Power On position. position. All necessary hardware is included for most installations. NOTE: The indoor Pro-C is not weather or water resistant, and must be installed indoors or in a protected area. This device is not intended for use by young children. NOTE: It is recommended that a licensed 2. At valves, attach a common wire to either solenoid wire of all valves.Additional modules may be added in increments The Pro-C controller is designed with a simple to use Power Lock feature of 3 stations (PCM-300) or a single 9-station (PCM-900) to expand the that assures that the modules are energized and firmly secured into the controller’s station capability to 15 stations. The battery allows the user to program the controller without AC power. Watering will not occur without AC power. Since this controller has non-volatile memory, the program clock and calendar will be retained during a power outage even if no battery is installed. When a pump is to be operated by the controller, a pump start relay is typically used. Hunter offers a full range a pump start relays for most applications. PSR Series. During the Manual Cycle, pressing the test button on the Mini-Click will interrupt watering. ConneCTInG a HUnTer reMoTe ConTrol (not included). The Hunter remotes make it 3. Screw the SmartPort harness housing. ConneCTInG To THe HUnTer solar sYnC The Solar Sync is a sensor system that, when connected to Hunter Pro-C, will automatically adjust your controller watering based upon SOLAR SYNC SENSOR changes in local climate conditions. There is no default program. The Pro-C is also capable of keeping the current time and date for an extended period of time during power outage conditions. Each valve is connected via wire to the sprinkler systems that are made today. They are the controller, valves, controller. There are some guidelines that should be followed when determining NOTE: It is usually good to water one or two hours when and how long to water. These factors are the soil type, the part before sunrise. Setting Program Start Times NOTE: If a program has all four start times turned off, 1. Turn the dial to the SET then that program is off (all other program details are PROGRAM START TIMES retained). Selecting Specific Days of the Week to Water Selecting Interval Watering 1. Press the button to activate a particular day of the week to water This feature is convenient if you want to (the display always starts with Monday). Press the button to have a more consistent watering schedule cancel watering for that day. Seasonal Adjustment After programming is complete, turn the dial to Seasonal Adjust is used to make RUN to enable automatic execution of all selected global run time changes without programs and start times.One Touch Manual Start and Advance You can also activate a program to water without using the dial. 1. Hold down the button for 2 seconds. 2. This feature automatically defaults to program A. You can select program B, or C by pressing program. The insert a delay between when Pro-C can be customized to display only the required programs. Programable Sensor Override When the Pro-C receives an input from the sensor to disable watering, the display will indicate those The Pro-C allows the user to program the controller so that the sensor stations that have been programmed to override disables watering on only desired stations. After the Hunter Quick Check completes running this circuit diagnostic procedure, the controller returns to. Only one start time per active program is ously waters, even when it should not be required. Refer to “Setting Program Start on (cycling repeatedly). The rain sensor is interrupting irrigation or Slide the Rain Sensor switch on front panel the sensor jumper is not installed.All necessary hardware is included for most installations. NOTE: The indoor Pro-C is not weather or water resistant, and must be installed indoors or in a protected area. This device is not intended for use by young children. NOTE: It is recommended that a licensed 2. At valves, attach a common wire to either solenoid wire of all valves.The battery allows the user to program the controller without AC power. Watering will not occur without AC power. Since this controller has non-volatile memory, the program clock and calendar will be retained during a power outage even if no battery is installed. When a pump is to be operated by the controller, a pump start relay is typically used. Hunter offers a full range a pump start relays for most applications. PSR Series. ConneCTInG To THe HUnTer eT sYsTeM ET SENSOR The Hunter ET System allows irrigation programs to be created automatically, based on local climate conditions. These programs are then loaded into the controller and run automatically. ET System uses a sensor to determine the local “evapotranspiration”. Scheduling of days to water, automatic controllers in the Hunter line-up, from the SRC to the Pro-C to run times, start times, cycle and soak operations, and more can now the ICC. Each valve is connected via wire to the There are three main components that are involved with all automatic controller. Here the wire is connected to a number that corresponds to sprinkler systems that are made today. There are some guidelines that should be followed when determining NOTE: It is usually good to water one or two hours when and how long to water. These factors are the soil type, the part before sunrise. Setting Program Start Times NOTE: If a program has all four start times turned 1. Turn the dial to the SET off, then that program is off (all other program PROGRAM START TIMES details are retained). Because there are no start position. Selecting Specific Days of the Week to Water Selecting Interval Watering 1. Press the button to activate a particular day of the week to water This feature is convenient if you want to (the display always starts with Monday). Press the button to have a more consistent watering schedule cancel watering for that day. Seasonal Adjustment After programming is complete, turn the dial to Seasonal Adjust is used to make RUN to enable automatic execution of all selected global run time changes without programs and start times.One Touch Manual Start and Advance You can also activate a program to water without using the dial. 1. Hold down the button for 2 seconds. 2. This feature automatically defaults to program A. You can select program B, or C by pressing program. The insert a delay between when Pro-C can be customized to display only the required programs. Programable Sensor Override When the Pro-C receives an input from the sensor to disable watering, the display will indicate those The Pro-C allows the user to program the controller so that the sensor stations that have been programmed to override disables watering on only desired stations. After the Hunter Quick Check completes running this circuit diagnostic procedure, the controller returns to. Only one start time per active program is ously waters, even when it should not be required. Refer to “Setting Program Start on (cycling repeatedly). The rain sensor is interrupting irrigation or Slide the Rain Sensor switch on front panel the sensor jumper is not installed.To attach the receiver to this type of controller, attach the blue and orange wire to the sensor input. SENSOR BYPASS Red light indicates sensor is bypassed. The closer the transmitter is Freeze-Clik model is important for accurate to the receiver, the better the reception. Do temperature sensing. To Each transmitter is produced with a unique bypass the sensor, press the SENSOR BYPASS address. Operation is subject to the following two conditions: 1. This device may not cause harmful interference and 2.