Error message

Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home1/dezafrac/public_html/ninethreefox/includes/common.inc).

7

canon powershot a1300 manual pdf

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:canon powershot a1300 manual pdf.pdf
Size: 2989 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 25 May 2019, 12:15 PM
Rating: 4.6/5 from 802 votes.

Status: AVAILABLE

Last checked: 1 Minutes ago!

In order to read or download canon powershot a1300 manual pdf ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

canon powershot a1300 manual pdfPAGE 2 ii COPYRIGHT NOTICE This manual is a publication of Maple Systems, Inc., and is provided for use by its customers only. The contents of the manual are copyrighted by Maple Systems, Inc.; reproduction in whole or in part, for use other than in support of Maple Systems equipment, is prohibited without the specific written permission of Maple Systems. The copyright of EasyBuilder-5000 and its related software belongs to Weintek Labs, Inc. PAGE 3 iii Table of Contents Connecting to COM1 and COM2 on Port B.24 COPYRIGHT NOTICE.PAGE 6 This page intentionally left blank 1010-1007, Rev. Using graphic HMIs has never been easier. This powerful family of graphic HMIs connects to programmable logic controllers (PLCs) to provide the human-machine interface in industrial applications. The HMI5000 Series has several features not found in other graphic HMIs. PAGE 8 2 EZware5000 Series Programming Manual In most cases, we will describe each method when the task is first discussed. The menu method is then used whenever the task is used in later procedures. Other conventions used in this manual are listed in the following table. Convention Bold Meaning Characters that you must type exactly as they appear. For example, if you are directed to type a:\setup, you should type all the bold characters exactly as they are printed. An OIT allows a plant floor operator to monitor current conditions of a control system and, if necessary, to initiate a change in the operation of the system. OITs connect to programmable logic controllers (PLCs) typically through the PLC’s serial communications port. PAGE 10 4 EZware5000 Series Programming Manual Graphics Object A Graphics Object is any text, icon, or picture that can be displayed on the HMI. Graphics objects are further defined by how they are composed or created. A Text Object is a graphics object that displays text on the HMI screen. A Bitmap Object is a graphics object that displays a bitmap on the HMI screen.http://csam-villepinte.org/uploads/images/enhance-ultrastor-rs16-manual.xml

    Tags:
  • canon powershot a1300 manual pdf, canon powershot a1300 manual pdf, canon powershot a1400 manual pdf, canon powershot a1300 manual pdf download, canon powershot a1300 manual pdf free, canon powershot a1300 manual pdf file, canon powershot a1300 manual pdf online, canon powershot a1400 manual pdf.

Bitmaps are files stored in the HMI to display pictures. A Shape Object is a graphics object that displays a shape on the HMI screen. PAGE 11 Introduction 5 List of Features The next chapter will guide you through the creation of your first project. Before you proceed, you may wish to read this brief list of some of the features offered in the EasyBuilder-5000 programming software. Bit Lamp Creates a graphic object to reflect the current status of a PLC bit. Word Lamp Creates a graphics object to reflect the current state of a multi-state PLC data register. Set Bit Creates a touchscreen graphics object that represents a two-state switch. PAGE 12 6 EZware5000 Series Programming Manual Video In Input and play video on the HMI from an external source (X-models only). Bar Graph Creates a bar graph with alarm monitoring. Meter Display Creates a scale meter. Trend Display Creates a trend graph. Samples data in single or multiple 16-bit PLC registers and plots the data on a time graph. History Data Display Displays historical data in a tabular format. Data Block Display Displays the data stored in a series of registers as a line graph. For a first time user, it is worthwhile to navigate through the screens in the demo project and become familiar with the features and capabilities of the HMI and EZware-5000. Refer to the EasyBuilder-5000 Help file for more information about the features and operation of the HMI and EasyBuilder-5000. PAGE 14 8 EZware5000 Series Programming Manual The X-models (HMI5104XH, HMI5121X, and HMI5150X) have an additional icon in the System Setup Toolbar for Screen Calibration. Older Models Newer Models Touch Panel Calibration Changing the System Settings ?To change the system settings on the HMI: 1. Open the System Setup Toolbar as described above, and click the System Settings icon. 2. A dialog will be displayed requesting the Local password. The default password is 111111. ? 3. PAGE 15 HMI Local Setup 9 6.http://sotel-perm.ru/site/enh908-nwy-manual.xml If using a static IP address, use the IP Address get from below option. The IP fields are enabled. Here, you can select your system passwords. 1010-1007, Rev. PAGE 16 10 EZware5000 Series Programming Manual 10. Configure your password settings. Local Password The password required to enter local setup. Upload Password The password required to upload data from the HMI to a PC or memory module. Download The password required to download data to the HMI from a PC or memory module. Password Upload (History) The password required to upload history files from the HMI to a PC or Password memory module. 11. The new password must be entered, and then entered again to confirm. PAGE 17 HMI Local Setup 11 13. Click on the HMI name tab to give the HMI a unique name. This name can be used to address the HMI for downloading over Ethernet. ? Downloading by name is supported only on the HMI5070TH and HMI5100TH, with Firmware version 20091002 or later. 14. Click the Firmware setting tab to access the Upgrade firmware option and the Portrait Mode settings (for models with the Portrait feature). PAGE 18 12 EZware5000 Series Programming Manual 15. Click the VNC server setting tab to enable remote access using VNC (Virtual Network Computing). Click Start VNC to enable the VNC server. Click the VNC login password to enter the password used to login to the HMI with a remote VNC viewer. The default password is 111111. Click Apply and then click OK to save the settings and exit the System Settings window. ? The VNC option is only available on Ethernet-equipped models. 16. PAGE 19 HMI Local Setup 13 The Popup download window option allows you to turn on or off whether the Download dialog window appears on the screen when a USB flash drive is connected to the USB port on the HMI. The CF Card tab displays information about the Compact Flash module. PAGE 20 14 EZware5000 Series Programming Manual 3. Click on the Version tab to display the current firmware information. The same dialog is displayed for transferring projects or data. ? Data is placed on the USB or CF device by EasyBuilder or Project Manager. Download Upload Restart Project and exit Cancel Time Remaining 1010-1007, Rev. PAGE 21 HMI Local Setup 15 When Download is selected, a dialog will appear requesting the Download password and what data to download. Password Download project files Download history files Clear history files Enter the Download password. When checked, the HMI will check the specified folder for project data, and transfer it if it exists. When checked, the HMI will check the specified folder for history data, and transfer it if it exists (includes data log files, event log files, and recipe files). This is accomplished via two 9pin D-sub serial communications connectors (Port A and Port B) and one Ethernet port. PAGE 24 18 Figure 4: COM Ports for the HMI5056N 1010-1007, Rev. This chapter will step you through the process of creating a sample project that can be downloaded to your HMI. The number 11 should already be in the Window No. field. 1010-1007, Rev. PAGE 35 Creating a Sample Project 29 5. Click the box for the Background color. The color palette box opens. Click on the white color box in the lower-right corner. The color box will reflect the color that you have selected. 6. Click OK. Highlight Window 11: Bargraph in the Open Window list, then click the Open button. Window 11 now appears on your work area. Now let’s create a function key to open Window 11 from the initial screen, Window 10. ?To create a Function Key: 1. PAGE 36 30 EZware5000 Series Programming Manual 5. Select shape number 7 and click OK. The Function Key Object’s Shape tab now shows a preview of how the function key will appear on the screen. Click OK. 6. On the main screen of EasyBuilder you will see a white rectangle outline that is attached to your cursor in the work area. This represents the function key just created. Click to place the function key in the middle of Window 10. In the New Text Object properties window, select Arial in the Font box and 16 pt in the Size box. Click the Color box and the color palette box opens. The color box will reflect the color that you have selected. 8. In the Content box at the bottom of the properties window, type To next window and click OK. PAGE 38 32 EZware5000 Series Programming Manual Now let’s create a bargraph on Window 11. We will use the bargraph to indicate the level of a tank. We will create pushbuttons to increase or decrease the level of the tank by turning a pump on and off. Alternatively, doubleclick on Window 11 in the Windows Option list on the left side of the EasyBuilder screen. ?To create a Bargraph: 1. PAGE 39 Creating a Sample Project 33 3. Click the Outline tab. Select it and click Open to add it to the list. 9. Select picture number 24 and click OK. This is the picture that will appear over the bargraph on the screen. 1010-1007, Rev. PAGE 41 Creating a Sample Project 35 10. Click OK to accept the properties settings. On the main screen of EasyBuilder you will see a white rectangle outline that is attached to your cursor in the work area. Click to place the Bargraph Object in the middle of Window 11. You can click and drag it to adjust its position once you have placed it on the window. Next we will create a pushbutton to raise the level of the tank and another one to lower the level of the tank.Select the Arrows 1 library. PAGE 43 Creating a Sample Project 37 12. Click OK and place the Set Word Object below the bargraph on Window 11 in EasyBuilder. You can click and drag it to adjust its position once you have placed it on the window. 13. Click on the screen to deselect the Set Word Object, then double-click on it to reopen the properties (or right-click on it and select Attribute) and click the Profile tab (the Profile tab is not available when creating a new object). Set the Width and Height to 60 (pixels). 14. PAGE 44 38 EZware5000 Series Programming Manual 16. Select LW for the Device Type and 0 for the Write address. PAGE 45 Creating a Sample Project 39 19. In the Attribute section, select the following: Set Style: Press and hold decrement (JOG--) (this will cause the value in the register to decrease while the button is pressed) Dec.Select the Arrows 1 library. Select shape number 8 and click OK. 21. Click OK to accept the properties settings. Select it and click Open to add it to the list. PAGE 47 Creating a Sample Project 41 6. Click OK and place the Bit Lamp Object to the left of the tank. You can click and drag it to adjust its position once you have placed it on the window. 7. Click on the screen to deselect the Bit Lamp Object, then double-click on it to reopen the properties (or rightclick on it and select Attribute) and click the Profile tab. Set the Width and Height to 50 (pixels). 8. Click OK to accept the new Profile properties. 9. PAGE 48 42 EZware5000 Series Programming Manual 11. Click the Profile tab and set the Width to 100 and the Height to 25 (pixels). 12. Click OK to accept the properties. Click to place the Bit Lamp Object between the pump and the tank. Now we will create a Set Bit Object to turn the pump and pipe on and off whenever the Up or Down Arrows (Set Word Objects) are pressed. ?To create a Set Bit: 1. PAGE 49 Creating a Sample Project 3. 43 Click the Shape tab and deselect the Use Shape checkbox. This will make the Set Bit invisible on the screen. 1010-1007, Rev. PAGE 50 44 EZware5000 Series Programming Manual 4. Click OK and place the Set Bit Object on the window. It will appear as a square frame. Click on the screen to deselect it, then double-click on it to reopen the properties (or right-click on it and select Attribute). Click the Profile tab and set the Width and Height to 65 (pixels). The Compiling dialog box appears. 2. Click the Compile button. EasyBuilder will compile your project and display error results. 3. If no errors occur, click Close. PAGE 52 46 EZware5000 Series Programming Manual 2. Click the arrow button to go to the next window. 3. Click and hold the arrow UP button to fill the tank. The pump turns green and the pipe starts blinking. Refer to the HMI5000 Series Installation Guide for more information. In order to download your project, you must first connect the HMI to your computer. There are two methods of downloading to the HMI, Ethernet or USB, depending on your model. If the HMI is properly connected to the PC, the status box on the download dialog will update with messages indicating the progress of the transfer. To decrease the amount of time required to download a project to the HMI, you can uncheck the Firmware option on EasyBuilder's download dialog once you have downloaded it once. A better way of testing changes made to a project is to use the computer to simulate the operation of the HMI. PAGE 56 50 EZware5000 Series Programming Manual Off-line simulation is also great for demonstrating the operation of the HMI and becoming familiar with the operation of the HMI before it is installed. If you want to simulate the interaction with a PLC when off-line, it can be done by creating additional windows on the HMI which allow PLC data input. ?To use off-line simulation mode from EasyBuilder: 1. PAGE 57 Simulator Mode 2. Click Online-Simulator. The Open Project dialog box appears. 3. Click on the compiled project file that you wish to simulate. 4. Click Open. The simulation screen appears. 5. To end on-line simulation, right click in the simulation screen and click Exit. 51 ? The above method will work with a standard PC serial COM port, regardless of the COM number assigned to the PC serial port. EasyBuilder is the application software used to create a project file. Project Manager is a utility application that puts the HMI into different operating modes. EasyConverter changes certain binary files created by the HMI into text files. Reboot HMI Connects to the HMI, checks password and resets the HMI in order to update system files. Connection Setting Select between Ethernet or USB cable (depending on model) for communication between the computer and HMI. PAGE 60 54 EZware5000 Series Programming Manual EasyBuilder-5000 Development Window Objects Summary EasyBuilder includes several active graphics objects that are used to represent data that is stored in the PLC or internal memory of the HMI. The data represented can be single bit coils, 16-bit, 32-bit, or 64-bit registers. The data can be represented as numbers, ASCII characters, or as graphic shapes or bitmap images. This section provides a summary of all the objects available in EasyBuilder-5000. PAGE 61 Using EZware-5000 55 Set Bit The Set Bit Object is used as a button to toggle ON or OFF the state of a bit or coil in the PLC, or a bit in the HMI local memory (LB). There are a number of different options (Set Styles) available to operate the button including touch (On, Off, Toggle, Momentary), window open or closed, and backlight on or off. Set Word The Set Word Object is used as a button to change the value in a PLC register, or the value in a register in the HMI local memory (LW). PAGE 62 56 EZware5000 Series Programming Manual Function Key The Function Key Object is used to change windows, popup a window, return to a previous window, close a window, or input data as part of a keypad. It can also be used to execute a macro or print the screen to a USB flash drive, SD card, or printer. Numeric Display The Numeric Display Object is used to display the current value in a register. The value can be displayed as BCD, Hex, Binary, or Decimal (signed or unsigned). PAGE 63 Using EZware-5000 57 Moving Shape The Moving Shape Object is used to move a shape or picture on the screen based on values in consecutive registers (specified by the Read Address). The value in the Read Address register determines the state of the object and can be used to change its appearance. The value in the next consecutive register(s) determines the position of the part (relative to the object’s initial position, in pixels). PAGE 65 Using EZware-5000 59 History Data Display The History Data Display Object is used to display historical data collected by the Data Sample Object in a table format. PAGE 67 Using EZware-5000 61 The Read address field is the starting address of the data to plot. Each channel has its own Read address. Normally, the X and Y data are read from two consecutive addresses beginning with the Read address. To have the XY Plot use separate addresses for X and Y data, check the Separated address for X and Y data checkbox. Separating the X and Y data addresses also allows the X and Y data to have different formats. PAGE 68 62 EZware5000 Series Programming Manual Line: The data is plotted as a Line graph, with squares plotted at each data point. Point: The data is plotted as squares at each data point. X-axis projection: The data is plotted as a line graph (no squares). The plot is filled along the X-axis. Y-axis projection: The data is plotted as a line graph (no squares) with the X and Y data transposed. The plot is filled along the Y-axis. PAGE 69 Using EZware-5000 63 to display (including the starting day). If three days are selected, but only two event files are included within the three day period, only two event files will be displayed. PAGE 72 66 EZware5000 Series Programming Manual Note: When transferring bits, bits can only be transferred to the local HMI’s internal memory. It is not possible to transfer bits to a remote HMI or another PLC. Data Sampling The Data Sampling Object is used to create Data Logs. A Data Log gathers data that can be saved as History files to the HMIs internal memory, or to a compact flash, SD card, or USB drive (depending on the model). PAGE 73 Using EZware-5000 67 Action modes include Bit ON, Bit OFF, or Word write. Bit ON: Start action sets the Action address bit. End action clears the Action address bit. Bit OFF: Start action clears the Action address bit. End action sets the Action address bit. End action writes the End value into the Action address register. Opening, Editing Projects ?To create a new project 1. On the File menu, click New or click the New icon in the Standard toolbar. The EasyBuilder dialog box appears. 2. Select the HMI model that you intend to use with your project and whether you want to use the HMI in Landscape or Portrait mode (if available for your model). PAGE 76 70 EZware5000 Series Programming Manual 3. Enter a file name and then click Save. 4. The main screen of EasyBuilder reappears. ?To save a project using the compress feature: The compress feature allows you to save a project in compressed format so that the project data takes less space on your hard drive. This utility also will save the graphics libraries associated with the project into the compressed file. You also have the option not to overwrite existing files, and in most cases this is okay unless the project being uncompressed uses modified libraries with the same names as the standard libraries in the Library folder. PAGE 78 72 EZware5000 Series Programming Manual 2. The Object List combines a list of all of the windows in a project, and all of the objects on each window, into a single tree. Notice that the tree displays the title for each window next to the window number. This makes it easy to determine the windows that have been created for a project. The tree will expand to list the objects on that window, as shown: 2. The Object ID of each object will be listed. PAGE 80 74 EZware5000 Series Programming Manual. PAGE 81 Using EZware-5000 75 ?To zoom in on the selected window 1. Use the zoom pull-down menu in the Edit Toolbar. Zoom levels range from 50 to 200 in 25 increments. 2. On the View menu, select Zoom Level. Zoom levels range from 50 to 200 in 25 increments. Another option is to display what are known as Object ID tags. Every time you create a new object in EasyBuilder, an Object ID tag is assigned to the new object. PAGE 82 76 EZware5000 Series Programming Manual Basic Editing Commands ?To select a graphics object 1. On the Edit Menu, click Select or click the mouse cursor icon in the Draw Toolbar. 2. Click on the graphics object. This causes the text box to be selected, with small square blocks around the edges indicating the boundaries of the object. Deselect the object by clicking somewhere else in the work area. 3. PAGE 83 Using EZware-5000 77 3. From the Edit menu, click Undo or click the Undo icon from the Standard Toolbar. Interval: This setting affects how EasyBuilder places the copies of an object on the screen relative to each other. The Pitch setting will interpret the X Distance setting as the distance from the left side of an object to the left side of the next object and the Y Distance setting as the distance from the top of one object to the top of another object. PAGE 85 Using EZware-5000 79 4. In the Destination box, enter the number of the window in the current project that you wish to copy the selected window(s) to. If multiple windows are selected, they will be copied into consecutive windows beginning with the one designated in the Destination window. 5. Click OK. The EasyBuilder Destination window is redisplayed with the Window Copy command executed. ?To delete a graphics object(s) 1. Select the object or objects you wish to delete. 2. PAGE 86 80 EZware5000 Series Programming Manual 4. All of the objects that use PLC data registers or the internal memory of the HMI are listed in this dialog box according to their Object ID tag. Alongside each ID tag is the PLC or HMI memory identifier. Grouping Objects When creating graphics on a window, you may create a complex graphic that is actually composed of several simpler objects grouped together. Grouping objects together makes it easier to move or copy multiple objects at the same time. PAGE 87 Using EZware-5000 Bottom Layer: Send the selected object to the bottom layer. Previous Layer: Next Layer: 81 Moves the selected object to the previous layer. Moves the selected object to the next layer. Normally, an object that is controlled by a PLC Register (i.e., a Word Lamp, Bit Lamp, Animation, etc.) is brought to the Top Layer when the value in the PLC Register changes. This behavior can be changed by the Object Layout option on the General tab of the System Parameters dialog. PAGE 88 82 EZware5000 Series Programming Manual ?To make objects the same size: 1. Select the objects you wish to make the same size. 2. From the Edit menu, select Make Same Size, then Both or click the Make Same Size icon from the Edit toolbar. Making Objects the Same Color This feature can be used to make two or more drawn objects the same color. ?To make objects the same color 1. Select the objects that you wish to make the same color. When the object is locked, its position and size cannot be changed. 1. Select the object you wish to lock. 2. From the Edit menu, select Pinned or click the Pinned icon from the Edit toolbar. 3. PAGE 90 84 EZware5000 Series Programming Manual System Parameter Settings The final section of this chapter shows all the settings or parameters that can be configured using EasyBuilder. From the Edit menu, select System Parameters. The System Parameter Settings dialog box appears. The Device Properties dialog appears. ? You can “export” a project created for one PLC brand to a different PLC brand by loading the project file into EasyBuilder, then entering a different PLC type in this box. This is the COM port used by the HMI. 8. Select Baud rate, Data bits, Parity and Stop bits. Use Maple Systems’ Controller Information Sheets or the PLC manufacturer’s operations manual for information on the communications parameters required by the PLC. PAGE 93 Using EZware-5000 87 ?To configure the Model tab settings: 1. HMI model: Select the HMI model that you are programming. 2. HMI station no.: When multiple HMIs are used, this selects the unique network address of the HMI. The project and all objects and graphics will be proportionately resized automatically. ? To auto resize your project using the Model tab in the System Parameters dialog: 1. In the Model tab, select a different display size from the HMI model drop-down box and click OK. 2. PAGE 95 Using EZware-5000 89 ?To configure General tab settings: 1. Fast selection button: The Attribute: drop-down enables or disables the fast selection button, which is used to open the Fast Selection window (window number 3). The Settings button sets the look of the button including shape and color. The Position drop-down sets the fast selection button on either the lower left or lower right portion of the display. PAGE 96 90 EZware5000 Series Programming Manual 3. Options: The Startup window no.Window 10 is the default startup window. The Common window determines if objects in the common window (window 4) are placed above or below the base window. The Object layout drop-down determines the layout and display of objects by selecting either Control mode or Nature mode. ? Normally, an object that is controlled by a PLC Register (i.e. PAGE 97 Using EZware-5000 91 ?To configure System Setting tab settings: 1. Startup language after redownloading the project: Select the language that the HMI is to use when restarting after a download. 2. Execute init. MACRO when power on: When checked, the HMI will execute the selected macro on startup. Available only when one or more macros exist in the project. 3. PAGE 98 92 EZware5000 Series Programming Manual 6. Disable buzzer: When checked, the HMI will not sound the buzzer (beep) when the screen is touched. Local Bit LB9019 can be used to control the buzzer. Set the bit to disable the buzzer and clear the bit to enable the buzzer. 7. Prohibit remote HMI connecting this machine: When checked, the HMI will not allow connections from a remote HMI. Local Bit LB9044 can be used to control remote connections. PAGE 99 Using EZware-5000 93 ?To configure Security tab settings: The Security tab is used to set up a table of users, user levels (access classes), and passwords. Up to 12 users can be individually enabled, and each has a unique password and combination of any six access classes (A-F). Only numbers are allowed for password. When an object is created, it can be assigned an access class (A-F). PAGE 100 94 EZware5000 Series Programming Manual The object can be configured to handle insufficient security in one of two ways. The object can be hidden while security is not sufficient. ? The HMI can display the message defined as Message 1 in the System Message object. There are a number of local HMI addresses that can be used with the security features. Address Description LB9050 Reset security level to 0 (no security) Boolean Set momentarily to trigger. To add a Windows TrueType font that is on your computer, click Add.There are 10 files that can be configured for saving data, em0.emi through em9.emi. Each extended memory location can be accessed using the Device Type setting in an object’s properties. The Download dialog box is displayed. 2. Check the Reboot HMI after download checkbox. 3. Click OK. Save and Compile the Project EasyBuilder can automatically save and compile the project when downloading or simulating. ?To enable automatic save and compile 1. PAGE 106 100 EZware5000 Series Programming Manual 3. By default, the converted file is automatically placed into the same directory. When converting to an EasyBuilder-5000 project, these text objects are converted to TrueType fonts. Use this section to specify which TrueType fonts you wish to use. PAGE 107 Using EZware-5000 7. 101 Click the Exit button to go back to the main screen of EasyBuilder-5000. Open the converted file as you would normally open any EZware-5000 project file. ? Due to some incompatibilities between the EZware-500 software and the EZware-5000 software, you should check each screen and test operation after conversion to make sure that your HMI works to your satisfaction. PAGE 108 102 EZware5000 Series Programming Manual Please Note: These files are captured by the HMI and stored in internal HMI memory, an attached SD card, or USB flash drive. You must copy these files into your computer before using the EasyConverter utility. If you are running a project that is capturing data log or event log files using the Offline Simulator, the EZware-5000 application automatically creates new folders on your computer and creates the files. PAGE 109 Using EZware-5000 103 2. Display Milliseconds: This option determines how the time value for each data record is displayed. The EasyPrinter utility must be running on the PC that is hosting the networked printer from which you wish the HMI5000 Series to print. General Port Number of the Server Socket: Specify the IP Port number to use. This must match the Port setting on the Printer Server tab of the EasyBuilder5000 System Parameters dialog. User Name: Specify a User Name. This must match the User Name setting on the Printer Server tab of the EasyBuilder5000 System Parameters dialog. Password: Specify a Password. In the example above, RW0 thru RW150 will be used. 3. PAGE 115 Using EZware-5000 109 integer format or BCD?). Therefore, the data format is used to define how each data element is formatted (ie., Signed vs Unsigned, 16-bit vs 32-bit, Float, String, etc.). a. Add: Click to add a new data register format.