Error message

Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home1/dezafrac/public_html/ninethreefox/includes/common.inc).

7

3m heat tracer manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:3m heat tracer manual.pdf
Size: 4340 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 3 May 2019, 17:36 PM
Rating: 4.6/5 from 688 votes.

Status: AVAILABLE

Last checked: 17 Minutes ago!

In order to read or download 3m heat tracer manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

3m heat tracer manualChecking your browser before accessing This process is automatic. Your browser will redirect to your requested content shortly. Page 4 General. Simple, One Button OperationThe one button operation of the IR-500 and IR-999 offers the ultimate. Page 5 Commercial. Alarms and Data Storage for Commercial. Temperature Monitoring. Page 6 3M Infrared Thermometers IR-60L2The IR-60L2 and IR-60CFO thermometer measure from a. Laser Accuracy and Data Logging for. Professional Temperature Monitoring. Infrared. Page 8 Use This Checklist to Start. Your Maintenance Program. Please check your inbox, and if you can’t find it, check your spam folder to make sure it didn't end up there. Please also check your spam folder. You can monitor equipment more closely, more accurately, and more often — and spot trouble before it leads to costly malfunction and repair. Be sure to order your IR-999, IR-1100, IR-1400, IR-60L2, or IR-60EXPL2 with certi.With single-point laser sighting, their point-and-shoot operation and back-lit LCD displays make them user friendly, with minimal training required for use. These units are lightweight yet durable enough to withstand daily use. Pick the unit that ?ts your application based on your measuring distance and the temperature range of the objects you wish to measure. With a 8:1 distance-to-spot ratio, it is best used within 4 feet of the object and has a temperature range of It features a 12:1 distance to spot ratio that allows more ?exibility in measuring hard to reach objects. The Sponsored Listings displayed above are served automatically by a third party. Neither the service provider nor the domain owner maintain any relationship with the advertisers. In case of trademark issues please contact the domain owner directly (contact information can be found in whois). The seller has relisted this item or one like this. Item may have a few minor cosmetic ” Learn more - opens in a new window or tab This amount is subject to change until you make payment.http://atlet-irk.ru/userfiles/3pjs-manual.xml

    Tags:
  • 3m heat tracer manual, 3m heat tracer manual.

For additional information, see the Global Shipping Programme terms and conditions - opens in a new window or tab This amount is subject to change until you make payment. If you reside in an EU member state besides UK, import VAT on this purchase is not recoverable. For additional information, see the Global Shipping Programme terms and conditions - opens in a new window or tab Learn More - opens in a new window or tab Learn More - opens in a new window or tab Learn More - opens in a new window or tab Learn More - opens in a new window or tab Learn More - opens in a new window or tab Learn more Please see pictures for actual physical condition. ” Contact the seller - opens in a new window or tab and request post to your location. Please enter a valid postcode. Please enter a number less than or equal to 1. Find out more about your rights as a buyer - opens in a new window or tab and exceptions - opens in a new window or tab. All Rights Reserved. User Agreement, Privacy, Cookies and AdChoice Norton Secured - powered by Verisign. With RCD protection provided you can be assured that your installation is both up to 17th Edition wiring regulation. Energising just before freezing, it provides an extremely efficient way of frost protecting your boiler condensate lines all year round with only 13mm insulation required for the pipe (not supplied). Proud to be a family business with a real focus on looking after our customers, we’ve been supplying industry-leading, competitively priced heating systems for over 20 years. Register Now Please check periodically for availability. It has a 110 volt power supply. Additionally, it stores up to 100 data points allowing for easy set-up of preventative maintenance programs. For the ultimate in data logging, the IR-60EXP2-1, adds the versatility of direct computer connection for data downloads or printing.http://XN--80AQIJC2D7A.XN--P1AI/userfiles/3pm-futaba-manual.xml This unit can mount to a tripod, where temperature data can be measured over an extended period of time and output directly to a chart recorder, printer, or PC. This 3M Infrared Thermometer comes standard with an RS232 cable, Windows-based software, power supply, hard plastic case, wrist strap and contact probe. 100 points in memory Display hold 60:1 distance-to-spot ratio 3 dot laser sighting locking trigger low battery indicator 2 x 1.5V Alkaline Type AA Battery -25degree F to 1600 degree F temperature range. The TPS31 is most suited for rooms where a timer unit is not required, or to provide floor temperature limitation when the heating is being controlled by a home automation system. The hidden functions include a heating schedule which can be turned on if desired providing the controller with full Lot20 compliance due to its increased energy efficiency. A blanking plate is supplied with the controller to hide the display if you would prefer not to see it. When you choose the ambient temperature the floor sensor still ensures the floor doesn’t overheat. As standard this function drops the temperature by 5oC, but it can be set to anywhere between 2-8oC. The signal is usually sent from an external timer or building management system (BMS), but in the case of hotels, can be a signal sent from reception when the room is unoccupied. This mode can be used in hotels to effectively turn off the rooms heating. This signal can be sent from an external timer, a BMS or simple wired switch. Set your room or floor temperature to operate the thermostat. The floor temperature limit should be set when you first switch on your thermostat. The standard pre-set heating schedule is as follow: Company registration number: 4905464 VAT no: GB 307 5500 28 In the case of membership of or affiliation with organisations please see our partner section for further details. Just swab the surface, click the activation solution and incubate in this heating block for 15 minutes.http://www.drupalitalia.org/node/67135 Interpret the results by a color change of clean or dirty. How? We are a single-source food, dairy and beverage plant supplier with a diverse product line, so you can findWe represent over 850 manufacturers, so you only have one vendor to contact—us. You'll appreciate ourGive us a try—you'll be glad you did. At this time, this product is Outside of this range, the instrument will show dashes in the display for the Heat Index.The unit will DOWN ARROW recognize the cable plugged in and configure itself for serial or parallel. If no Changes items appearing in the display. Scrolls down. cable is plugged in it will default to serial. Slots in the housing allow air to circulate around the sensor.SPECIFICATIONS accessed by removing the screws from the bottom panel of the unit. Measurements: The 2-position switch located in the battery compartment must be set by the user Globe, dry bulb, wet bulb, WBGTin, WBGTout, WBGT weighted average if the power supply method is changed. APPENDIX A: HEAT EXPOSURE TABLES 2 additional sensor bars by using remote cables up to 200 feet (61m). The top sensor bar can also be remote with a cable. Sensor array with 2 inch globe 56-795 A time of 4:01 indicates greater than 4 hours. Sensor array with 6 inch globe 56-780 6 Foot shielded remote sensor cable 53-924. For Service Information U.S.A. customers, we will replace or repair (our option) defective instruments at no Congratulations. Paladin is suitable for installation on the outside of both metallic and non-metallic pipes and carries approvals for both direct earth burial and wet locations. As a result Paladin for Pipe can be installed both indoors and outdoors. Paladin being a very versatile product can also be installed inside most non-pressurized, non-potable pipes and drains as Heat-Line offers the only external heating cables on the market that are wet location certified by cCSAus.http://cristianpack.com/images/3m-intracom-d-20-manual.pdfThis includes but is not limited to copper, PEX, polyethylene, ABS, PVC, galvanized, stainless, ductile iron, rubber, vinyl and more. Even in applications where pipes are intended to be dry for short or extended periods of time, Paladin will never over-heat or melt the pipe due to its advanced self-regulating technology. The need for an electrician to provide on-site power and complex terminations is eliminated. Paladin is the only known heat tracing cable available on the market that carries direct earth burial and wet location approvals making it suitable to install in a variety of applications like never before. Constructed of self-regulating heat cable technology the Paladin can effectively increase heat and energy output to sections along its length which are cold and simultaneously reduce heat and energy output to sections which are warm. You never have to worry about the Paladin pipe warmer system overheating causing risk of melting and fire because of the self-regulating heat trace cable technology. Paladin gives you the peace of mind of reliable pipe freeze protection without the risk. It has become an essential product for farmers and barn managers to provide safe and reliable freeze protection in barns and stables. The additional thermal insulation works to reduce heat loss, and the thermostat allows you to duty cycle your Paladin system based on external pipe temperature. Both accessories combined can increase energy efficiency by as much as 80. Examples include but are not limited to: Examples include but are not limited to: Other hardware store heat tape products must be pitched or spiraled around the pipes in order to apply the adequate amount of heat to un-insulated pipes, making them very high in energy consumption. With Paladin, the heating cable is simply applied on to the pipe in a single run in most applications; reducing overall length of product by as much as 60. (see Measuring Recommendations). If you feel you have a special or unique application for Paladin please contact Heat-Line directly and speak with one of our knowledgeable product specialists. No extra electrical work is required (Cord set (hard wire) connected Paladin models available upon request) Do not assume or estimate the length required as the Heat-Line Paladin for Pipe heating cable system cannot be extended. For example, if an 18 ft. (5.5m) system was required, round up to a 20 ft. (6m) system. There is no way to lengthen the Paladin for Pipe product when on site. For custom or non-stock orders Paladin can generally be shipped out within 1-3 days from time of order. Please call for current availability and lead times. For a quotation on this product and more CLICK HERE. The Paladin system though however carries an additional certification designation that the EXT5R does not which makes the Paladin product certified for use in Roof and Gutter de-icing applications. The advance self-regulating technology employed in the Paladin product renders it safe on plastic pipes even when dry as it can never overheat and damage the pipes. This unique ability means that the overall length of heating cable required greatly reduced, decreasing overall operating costs. Depending on system applications, or where automatic operation is preferred, a thermostat can be used to switch the system on and off to help conserve power or to duty cycle the system. When combined with insulation thermostats can substantially increase energy efficiency. As a result, most Heat-Line systems, including Paladin can be installed by homeowners; however, Heat-Line commonly recommends that a qualified tradesperson complete the installation process If needed it is safe for the heating cable to overlap as it is self-regulating and will not overheat. As a result, Heat-Line brand products are very energy efficient to operate, but do not completely shut off as they can only idle their output to a minimum amount. To completely shut off the system it must be unplugged or installed with a thermostat. Heat-Line brand systems should be unplugged or shut off when not required (summer months) and tested each year before use. We pay for the energy in watts, not in volts. Years ago the term more efficient was attached to 240 volt systems because you can put more load or amperage on a 240 volt circuit. Unfortunately, the term more efficient somehow became misinterpreted to mean more energy efficient which is not the case. Once re-energized the Paladin system has the ability to increase its output to immediately begin to defrost any section of the pipe that has or was close to freezing during the power outage. In many instances defrosting the pipe can take as little as an hour or less. While the overall amount of energy consumed depends on multiple factors you can be assured that you are installing the most energy efficient heating cable system available. If you would like to reduce your energy consumption further you can investigate the addition of a thermostat, timer, and or other control device. For applications that require longer lengths please see EXT5R. Once you have the required information collected including pipe type (metallic or non-metallic), pipe diameter, pipe length, lowest outdoor ambient temperature, number of valves or external spigots, and potential insulation thickness you employ the Paladin length selection chart or contact Heat-Line directly to speak with a product specialist. As such the Paladin system cannot be spliced together in the field. If greater length of the Paladin is required you may purchase a single continuous product of the proper length, and or relocate a second power source and install an additional Paladin system to complete the required freeze protection. A common type of insulation employed with Paladin heating cables is fire resistance water proof pipe foam insulation sleeves. You are also able to implement fiberglass insulation provided it is properly weatherproofed based on the environment. For 12 volt or 24 volt DC applications see Kompensator. It also helps keep the heating cable in consistent contact with the pipe and works as a form of protection to prevent damage to the heating cable. Spare equipment should also be available at the owner s site. Equipment manufactured by the manufacturer is protected against normal line surges. High surges caused by thunder storms or power supply equipment may damage this equipment. For added security against line voltage surges it is recommended that surge and noise suppression devices be installed at the electrical distribution panel. Use of shielded cable for probes is recommended for protection against lightning. These devices are available from most electrical supply distributors. RECOMMENDATIONS The manufacturer recommends that all installation procedures described herein be performed by a qualified electrician or installation technician. Further more the manufacturer recommends to test all the functions and equipment connected to the ECS, including the alarm system and backup devices, after installation, after changes to the installation and every month after that. Fuse verification and replacement, as well as the proper setting of control values shall be the responsibility of the owner of this equipment. It is organized as follows: Introduction Installation User s Guide Appendix 1.1 DESCRIPTION Congratulations on the purchase of your ECS-3M environmental control system. The ECS-M product line provides you with full control over temperature, humidity, air flow, and heat, resulting in a comfortable environment for your livestock. The ECS-M product line offers a number of added features over existing ECS controls, such as: Compatibility with DIP-1 control. Automatic temperature reduction (ramping). Adaptable variable speed outputs for a wide selection of fan model types. Humidity probe. Full torque fan start to prevent motor damage. The ECS-3M provides microprocessor control over a three stage output. The first stage controls a variable speed fan which can operate at a continuous low speed to ensure good quality of air when room temperature is below the main set point. In addition, the first stage may be programmed to cycle ON and OFF. When room temperature rises above the main set point, the fan accelerates to increase the airflow. Page 5 6 ECS-3M DESCRIPTION CONTINUED. The second stage provides control over a second variable speed fan to help the first fan when higher room temperatures require increased airflow. This second stage is also fully programmable for settings, such as minimum speed, relative set point, etc. The third stage controls either a heater for colder climates, or a third fan where additional cooling is required. The ECS-3M provides you with full control over all three stages via the use of an easy to follow display panel. All programmable features can be customized to meet your requirements. The ECS-3M keeps you constantly informed by displaying the status of all of its outputs as well as the room temperature. With an optional humidity probe, the ECS-3M displays current humidity levels. Safety of livestock is ensured by the continuous control of climate and timely alarm notification, should environmental conditions exceed alarm set points. Further security may be obtained by connecting all ECS controls in a network configuration to a computer via the use of an optional RCM- 40 remote monitoring unit. This provides remote control monitoring of each room. All control panel variable outputs are fused, and all programmable settings are maintained, whether the ECS-3M is powered or not. The ECS-3M provides an automatic constant temperature reduction (ramping) feature for your maturing livestock. A built-in low temperature safety factor prevents temperatures from reaching dangerous limits. With an ECS-3M in control of your climate, you are assured of optimal living conditions for your livestock. Page 6 7 DEFINITION OF TERMS DEFINITION OF TERMS MAIN SET POINT The desired room temperature. Other temperature settings on the ECS-3M are relative to the main set point temperature. RELATIVE TEMPERATURE A value added to, or subtracted from the main set point, which results in a new temperature at which a desired action starts or stops. ROOM TEMPERATURE The actual temperature in a closed area. ROOM HUMIDITY The actual humidity level of a closed area. MINIMUM FAN SPEED The desired minimum speed for variable speed fans. RAMPING An automatic daily reduction in the main set point and all temperature settings relative to this. Range of temperature where two conditions are possible. The output depends on whether the temperature was increasing or decreasing when it enters that range. VARIABLE. (Bandwidth) Temperature range where a variable fan speed fan accelerates, as the temperature increases. Page 7 8 ECS-3M Page 8 9 CHAPTER 2 - INSTALLATION Chapter 2 describes the installation of the ECS-3M control panel. The manufacturer recommends that the following instructions be adhered to as closely as possible, and that all work be performed by a certified electrician. Failure to do so may void the warranty! 2.1 UNPACKING Unpack the ECS-3M and inspect contents for damage. Should the contents appear to be damaged, contact your local distributor for return procedures. The package should contain the following standard items: 1 ECS-3M control. 1 installed temperature probe (model number K). 3 cable fasteners or fuses. 1 Instruction manual. The following optional items may be added: 3 additional temperature probes for temperature averaging, 1 humidity probe. The ECS-3M requires the RHT-1 humidity probe for maximum accuracy of monitoring and control of humidity levels. Page 9 10 ECS-3M 2.2 MOUNTING Use a screwdriver to remove the faceplate and the plate on the power compartment. To limit the unit s exposure to noxious gases, install the unit in a hallway. Make sure the unit is mounted right side up with the cable entry holes facing down. The ECS-3M operates in a temperature range of 32 F F (0 C - 50 C). The enclosure is watertight, it is not splash proof or immersion proof. DO NOT WATER the control. Once both faceplates are off, install the mounting screw on the wall and install the unit on it. Use two more screws to secure the ECS-3M in place using the bottom mounting holes. Mounting hardware is not shipped with the unit. 2.3 SWITCH SETTINGS The ECS-3M is configured for a variety of options via two switches as follows: Line Voltage 230V Selector Switch This switch is located on the surface of the main (bottom) board and 115V adapts the control panel for 115 VAC or 230 VAC line voltage. Page 10 11 CHAPTER 2 - INSTALLATION Software Settings Switch This switch is located at the rear of the control panel faceplate and adjusts the following options. All settings except for main set point, record low, and record high are locked when this switch is OFF. Selects between a Heater or Fan control on stage three of the control panel. Make certain that the line voltage selector switch is set to 115 VAC. Connect the power cable to terminals 7 and 8 on the main (bottom) board and connect the ground wire to terminal 9 on the main board. Page 11 12 ECS-3M VAC Make certain that the line voltage selector switch is set to 230 VAC. Connect the power cable to terminals 7 and 8 on the main (bottom) board and connect the ground wire to terminal 9 on the main board Fan 1 (terminals 5 and 6) Stage 1 of the ECS-3M controls the operation of the primary fan. Connect the two leads from fan 1 to terminals 5 and 6 on the main (bottom) board Fan 2 (terminals 3 and 4) Stage 2 of the ECS-3M controls the operation of the secondary fan. This contact closure is voltage rated to 230 VAC. The current rating of the dry contact is 10 Amps (resistive) for a heater and 6 Amps (inductive) for a fan. Set the software settings DIP switch at the rear of the control panel faceplate to ON for a fan or OFF for a heater. These cables can be extended to a distance of 150 meters (500 feet). Single probe temperature and humidity connections are illustrated in figure 4, while temperature probe averaging connections are illustrated in figure 5. Page 12 13 CHAPTER 2 - INSTALLATION Use shielded cabling for probes. Connect the shields to the SHLD terminal. Failure to do so may result in inaccurate readings. Single Temperature Probe Install a single temperature probe in the area that best reflects the overall room temperature. Connect the two leads and the shield of the temperature probe to the control panel terminals labeled Probe, as indicated in figure Averaging (optional) Four temperature probes are required if temperature averaging is desired in larger rooms. Place the probes in appropriate locations to best average room temperature. Refer to figure Humidity Probe (optional) Install one humidity probe in the area that best reflects the overall room humidity. Connect the humidity probe to the control panel terminals labeled Probe, as indicated in figure ALARM The ECS-3M provides a normally open and normally closed dry contact for alarming low or high temperature conditions. In addition, this same contact can be used to signal a power failure. Make normally open or normally closed connections as indicated in figure 4. Momentary power interruptions may trigger false alarms! To avoid them, when the ECS-3M is connected to an alarm system, install a time delay relay between Page 13 14 ECS-3M 2.7 POWERING UP Before powering up the ECS-3M, install the faceplate to the control s enclosure using the six screws previously removed. Set Selector knob to position (12). Upon power up, the unit will test its display by briefly lighting all the segments of its LED. Make certain that all segments light up. Following the LED display test, the unit displays the room temperature. If the temperature does not appear, refer to the Troubleshooting section in the appendix of this document. Fig. 1 Two Fans (115V) and One Heating Unit (115V) Page 14 15 CHAPTER 2 - INSTALLATION Fig. 2 Three Fans (230V) Fig. 3 Two Fans (230V) and One Heating Unit (115V) Page 15 16 ECS-3M Notes for Figures 1, 2 and Power cut and protection devices in case of overload. Only use fans that have thermal protection devices. It is therefore strongly recommended to install backup devices and alarm or warning devices (see example fig. 7). BACKUP THERMOSTAT. If the control is defective, then the thermostat will start the dedicated fan at full speed when the temperature will reach the T15-WD set value.The relay shall be chosen to support the load connect to it. ALARM CIRCUIT. In normal operation, the alarm circuit of the Varifan control is a short circuit. But if the control is defective or if there is no power applied to it, then the alarm circuit of the control will be an open circuit. Page 18 19 CHAPTER 2 - INSTALLATION Fig 7. Recommended control backup Page 19 20 ECS-3M CHAPTER 3 - USER S GUIDE The ECS-3M front panel shown previously features a LED status window and two control dials which are used respectively to select a function and adjust a setting. LED STATUS WINDOW The LED status window features a 3 digit LED readout for the display of temperature in Fahrenheit or Celsius, humidity level, and programmable settings. In addition, the LED status window displays the operational status of Fans 1, 2, and Fan 3 or a heater via four additional LEDS (shown above in LED window). When ON, each LED indicates that its associated fan or heater is operating. The fourth LED lights up to indicate a low or high temperature alarm condition. CONTROL DIALS The center dial is the Selector dial and is used to select one of the control panel s 12 primary or 10 secondary functions. The dial located to the right of the Selector dial is the Adjuster dial and is used to enter secondary function mode and to adjust the setting of each function. When primary functions 1 through 11 are selected, the LED status window displays a blinking value. Function 12 displays ambient temperature. Then rotate the selector dial from function (12) to any other function. When secondary functions 1 through 4, 6, and 8 through 11 are selected the status window displays a flashing value along with a scrolling LED display. Selection of function 12 takes the ECS back to primary mode. Page 22 23 CHAPTER 3 - USER S GUIDE PRIMARY FUNCTIONS MAIN SET POINT 1 The main set point establishes the target temperature in the building. This value is used as the reference point for other settings. The main set point temperature is adjusted in 0.5 degree increments from a minimum setting of -9.5 C (13.5 F) to a maximum setting of 41.0 C (105.0 F). Adjusting the main set point temperature: rotate the Selector dial to position (1), rotate the Adjuster dial counterclockwise to decrease the temperature setting, clockwise to increase it. The main set point temperature is displayed on the ECS. Note: The reduction per day feature (primary function 9) must be (OFF) to Page 23 24 ECS-3M FAN 1 DIFFERENTIAL 2 The Fan 1 differential setting establishes the temperature at which Fan 1 reaches maximum speed. The value is a temperature difference from the main set point. The Fan 1 differential is adjusted in 0.5 degree increments from a minimum setting of 2.0 F (1.0 C) to a maximum setting of 18.0 F (10.0 C). Adjusting the Fan 1 differential: rotate the Selector dial to position (2), rotate the adjustment dial counterclockwise to decrease the temperature setting, clockwise to increase it. The Fan 1 Differential setting is displayed on the ECS. Example: A main set point temperature of 70 F along with a Fan 1 differential setting of 5 F is set. When the temperature of the room reaches 75 F, Fan 1 operates at its maximum speed. Page 24 25 CHAPTER 3 - USER S GUIDE FAN 1 MINIMUM SPEED 3 This function sets the minimum speed of Fan 1 when room temperature is below the main set point. This value is entered as a percentage of a fan s maximum speed. The Fan 1 minimum speed is adjusted in 2 increments from a minimum setting of 12 to a maximum setting of 100. Adjusting the minimum speed of Fan 1: rotate the Selector dial to position (3), rotate the Adjuster dial counterclockwise to decrease fan speed, clockwise to increase it. The minimum fan speed is displayed on the ECS. NOTE: Upon start-up, Fan 1 will run at its maximum speed for 4 seconds. This feature helps to minimize the risks of jams caused by ice. Page 25 26 ECS-3M FAN 1 DUTY CYCLE 4 As long as the actual temperature is below the main set point, Fan 1 operates at the minimum speed set by Fan 1 Minimum Speed (primary function 3). The Fan 1 duty cycle sets the percentage of time the fan is ON versus the percentage of time the fan is OFF. The ON time is entered as a percentage of the total time which is known as the period. The Fan 1 duty cycle is adjusted in 5 increments from a minimum setting of OFF, 5, 10 etc., up to a maximum setting of ON corresponding to continuous operation. Adjusting the duty cycle of Fan 1: rotate the Selector dial to position (4), rotate the Adjuster dial counterclockwise to decrease the duty cycle, clockwise to increase it. The duty cycle is displayed on the ECS. Example: The period of Fan 1 is set to 8 minutes by secondary function (4), while the duty cycle is set to 50. As long as the main set point temperature of the room has not been reached, the fan operates at a minimum speed for 4 minutes, and OFF for 4 minutes. Page 26 27 CHAPTER 3 - USER S GUIDE FAN 2 RELATIVE SET POINT 5 The Fan 2 relative set point establishes the temperature above the main set point at which Fan 2 begins to operate at its minimum speed.