3m attest incubator manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:3m attest incubator manual.pdf
Size: 3236 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 18 May 2019, 22:11 PM
Rating: 4.6/5 from 579 votes.
Status: AVAILABLE
Last checked: 15 Minutes ago!
In order to read or download 3m attest incubator manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
3m attest incubator manualOptional Visual pH Color Change Result Easy ConfigurationData is only stored for the last 100 incubated BIs. Using the Configuration PagePage 14 Made in U.S.A. by. All rights reserved. Reduced incubation time with Attest biological indicator products can improve inventory levels and increase turns.Learn more. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. After sterilization, the vial is ''crushed'' to join the growth media with the processed spore strip. The BI is incubated for 48 hours for a visual change readout. A color change to yellow indicates surviving spores and a positive result. We also use cookies to collect information for making reports and to help us improve the site. The cookies collect information in an anonymous form. Create one here. Creators are allowed to post content they produce to the platform, so long as they comply with our policies. United Kingdom. Company number 10637289. If this product is used in a manner not specified, the protection provided purposes only, and shall not be used for clinical or maintenance evaluations. Data shown by the product may be impaired. The C1 caution code will disappear when proper incubation temperature is reached. To change the 1. The LCD display will indicate detected malfunctions by displaying a caution or error code under affected BI wells. The audible alarm, if active, sounds and the LCD display backlight flashes to alert the user to all caution (except C1) and error codes. All rights reserved. 3M Deutschland GmbH 2510 Conway Ave. 3M and Attest are trademarks of 3M. Health Care Business St. Paul, MN 55144 Used under license in Canada. Carl-Schurz-Str. 1. For use in every load ofEasily and accuratelyUse to consolidate all sterilization process data into an easily accessible database. Regular compliance.http://erboka.org/userfiles/3m-service-manual.xml
- Tags:
- 3m attest incubator manual, 3m attest steam incubator manual, 3m attest steam incubator 56 manual, 3m attest steam incubator model 116 manual, 3m attest incubator manual, 3m attest incubator manual 2017, 3m attest incubator manual 2016, 3m attest incubator manual download, 3m attest incubator manual instructions, 3m attest incubator manual online, 3m attest incubator manual free, 3m attest incubator manual form, 3m attest incubator manual template, 3m attest incubator manual.
All related items caused by this demand are Non-Returnable.Biological indicators provide the best assurance of sterility by challenging the sterilizer with quantifiable, highly resistant spores. Gives clear, easy to interpret readout of the effectiveness of the sterilization process with results in 48 hours. With one of the largest catalogs of medical, surgical and diagnostic supplies available online, Medex Supply can accommodate your facility's needs for Surgical Supplies. Sterilization Tests can be found in our extensive online collection of products from globally recognized and trusted brands, including 3M. An excellent option to consider is the Attest Monitoring Starter Kit. They give you even3M Attest Auto-reader 390 for Steam. Auto reader for use with 3M Attest Rapid Readout Biological Indicators and Process Challenge Packs for Steam. 290 Auto-reader. Operator’s Manual. Manual Incubadora Attest 290 Instructions Read and understand all safety information before using this product. There are no user serviceable parts.Summary of Contents of user manual for 3M 390G. Manual Incubadora Attest 290 2016 An item that has been used previously. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections.Seller Notes:“ This incubator is in great cosmetic condition. It was tested and in working order. Replaces the 3M Attest Auto reader 290. Featuring advanced electronics and backlit LCD panel, the 3M Attest Auto-reader 390 turns up the dial on reliability and accuracy. It gives you even more confidence in your efforts to ensure patient safety, while working with your existing 3M Attest Rapid Readout products. Includes ethernet cable for web app connectivity. Louis, MO 63144 All Rights Reserved. Disinfection and Sterilization 3M Attest Biological Indicator System Complete Training.http://www.miragetravel.com.au/userfiles/3m-steri-vac-5xl-service-manual.xml Campbell from Milwaukee Area Technical College's Dental Hygiene program discusses Attest Biological testing. Read online 3M Attest ERapid Readout Biological Indicator book pdf free download link book now. Test results are known in hours. 3M Attest Rapid Readout biological indicator system for use with ethylene oxide or moist heat processing is 3m attest 1292 manual a proprietary technology that provides the fastest biological indicator result available. Save this Book to Read 3m attest rapid readout biological indicator PDF eBook at our Online Library. Features; Self-contained technology plus results in 4 hours for ethylene oxide or 3 hours for moist heat. M Purification: 3. All books are in clear copy here, and all files are secure so don't worry about it. The Attest Biological Monitoring System is a convenient, reliable system for monitoring steam sterilization. Test packs present a challenge to the sterilization process equivalent to the AAMI recommended test packs. 3M Attest Rapid Readout Biological Indicators for Gravity Steam Sterilizers. Benefits: Provides results in three hours. The 3M AttesTm Auto-reader is designed to incubate and automatically read the 3M AttestTM Rapid Readout Biological I 3m attest 1292 manual ndicators for Steam, and, at 60TC for a final fluorescent result at 1 hour for and 3 hours for The 3M AtteStTm G Auto-reader is designed to incubate and automatically read the 3M. The vial capacity meets the needs of both small and large offices. Buy 3M Attest Rapid Readout Biological Indicator For Steam with an everyday low price and fast shipping. No manual, cables or other accessories. Siskind Solution Manual Free Download Analysis Of Electrical Machines Solution Analysis Od Electrical Machines Solution 3m Attest Operation Manual For Machines Theory Of Machines. The Attest TM Biological Monitoring System is a convenient, reliable system for monitoring steam sterilization.http://www.drupalitalia.org/node/67018 Get 3m attest rapid readout biological indicator PDF file for free 3m attest 1292 manual from our online. The pack is specifically designed to present a resistant challenge to the steam sterilization process as does the AAMI 16 towel pack. Get 3m attest rapid readout biological indicator PDF file for free from our online. Self-contained biological indicators significantly reduce possibility of contamination, minimizing false positives and assuring more accurate results. The presence of Geobacillus stearothermophilus spores is detected by a visual color change (media turns yellow). Biological indicators are used for load control monitoring which is the process by which a load is monitored and released based on the result of a biological indicator (BI) in a test pack. Self-contained biological indicators 3m attest 1292 manual significantly reduce possibility of contamination, minimizing false positives and assuring more accurate results. Add to comparison Compare. Attest Steam Indicator Incubator by 3M Healthcare. Each pack contains one 3M(TM) Attest(TM) Rapid Readout Biological Indicator (Brown Cap) 3M Attest Rapid Readout Biological Indicator Test Pack that presents a challenge to the sterilization process equivalent to the AAMI recommended towel pack for C (F) Gravity Displacement Cycles and C (F) Vacuum Assisted cycles. The results can be documented in the Attest Record Book. Biological indicators are used for load control monitoring which is the process by which a load is monitored and released based on the result of a biological indicator (BI) in a test pack. Search Load Control Products. Rapid 5 Steam-Plus Test Pack is designed to monitor steam sterilization processes.Free shipping for many products. Disinfection and Sterilization 3M Attest Biological Indicator System Complete Training. M Purification: 3.http://arteratech.com/images/3m-breathe-easy-papr-manual.pdf 3M Attest Rapid 5 Steam-Plus Test Pack is a biological indicator test pack that contains a 3M Attest Rapid Readout Biological Indicator and a 3M Comply SteriGage Steam Chemical Integrator. Interestingly, this is something that has only become commonplace over the past two decades. Before that, it was only disinfected and cleaned. They also had to make sure that all their equipment was properly sterilized. Common equipment such as the dental drill was not made to be sterilized after every procedure, and this led to products continuously being in repair. In fact, some instruments even developed rust! These are able to kill all of the main spores, viruses, fungi, and bacteria. It also has to use set temperatures and pressures. It is even possible to use a flash mode sterilizer, which is even hotter and has even more pressure. To date, no living organism on earth can survive that. Sometimes there is a failure in the heating equipment, or in the gasket, or it may develop cold spots, or it may be overfilled. This is why it is so important that they are tested properly, which is possible thanks to 3m attest, which looks at various biological indicators. These are separated from each other using a crushable glass tube. It also comes with a log book and an incubator. This means that no bacteria grew. If the result is bad (a positive reading), then the color will turn yellow. This means that the bacteria have grown. If the result is positive, the autoclave should be cleaned and a new test should be completed. If the test is still positive, then the autoclave needs repairs. This way, as a dental office, you will know for sure that the equipment is always fully sterile. If a person gets bitten by a black. Although many people have been lectured over and over on. A fretting mounting issue, which is much more prominent in people. It acts as a visible introduction that often provides a memorable first. Notify me of new posts by email. Learn how your comment data is processed. Our site brings you medical and health related information that is written by our passionate team of medical journalists in a way that is easy to understand. Our website services, content, and products are for informational purposes only. Healthtian does not provide medical advice, diagnosis, or treatment. See additional information. Healthtian may earn a commission when you buy through links on our site. FOLLOW US. CRUSH AND TAP Attest Auto-reader Diagram Cajibrz:on BJttm Wels YElcw tor calibratm 'I-IV orange indb. The 3m attest 1292 service manual Attest biological monitoring system was developed by 3M to deliver 3m attest 1292 service manual a 3m attest 1292 service manual reliable and sensible methodology for monitoring sterilization. Equipment shipped worldwide. M Purification: 3. 47 Results. Confirm that it has cooled for at least 10 minutes. Complete 3m attest 1292 service manual with NEW 3m attest 1292 service manual power. Built-in fluorescent reader with 3m attest 1292 service manual manual calibration and readout in 1 or 3 hours. Sponsor: 3m attest 1292 service manual 3M Infection Prevention Division APR 3m attest 1292 service manual 3M Center, Bldg W St. The Attest Auto-reader 3m attest 1292 service manual complies with the EMC. Sterilization of medical instruments and supplies is 3m attest 1292 service manual essential to reduce and eliminate contamination and infection. The Attest 3m attest 1292 service manual biological monitoring system was developed by 3M 3m attest 1292 service manual to deliver a reliable 3m attest 1292 service manual and sensible methodology for monitoring sterilization. Confirm that it has cooled for at least 10 minutes. Sign up for our 3m attest 1292 service manual Specials. If you do not have a 3m attest 1292 service manual medical license on file, you will be asked to provide one before your order ships. - Make sure a properly rated power cord is installed on the Attest 3M Attest Rapid Readout Biological Indicators for 3m attest 1292 service manual Gravity Steam Sterilizers.January offers. 3M A Process Monitor Log Book 3m attest 1292 service manual with 50 Record Charts, Blue, For Professional License Required. Sponsor: 3M Infection Prevention Division APR 3M Center, Bldg. Manuals and free owners instruction pdf guides. Attest Products 47 Results. Please See 3m attest 1292 service manual More Product Details Below. 3MS. Test packs present a challenge to the sterilization 3m attest 1292 service manual process 3m attest 1292 service manual equivalent to the AAMI recommended test packs. Suggested Applications Monitoring Ethylene 3m attest 1292 service manual Oxide Sterilization cycles Used in conjunction with the Attest G Auto-Reader for EO Biological indicators and test packs 3m attest 1292 service manual that monitor the effectiveness of the EO sterilization process and 3m attest 1292 service manual provide results 3m attest 1292 service manual within 4 hours. Free shipping for many products. All 3M Products; Attest; Attest Products. You must have a 3m attest 1292 service manual license on File in order for your 3m attest 1292 service manual order to be processed.Find the user manual and the help you need for the products you own at ManualsOnline.These indicators are convenient, compliant, and 3m attest 1292 service manual efficient 3m attest 1292 service manual sterility 3m attest 1292 service manual assurance monitors available in standard 3m attest 1292 service manual hour readout, and rapid hour readout modes. Free shipping for many products! 3M 3m attest 1292 service manual Attest AutoReader. Obtain a sterilized. 3m attest 1292 service manual We supply 52 different specialties of medical, hospital, health care, radiology and clinical equipment. Pour une meilleure experience web, prenez le temps de mettre votre navigateur a jour. The wait time to speak to one of our customer service representatives will be longer than usual. All other inquiries regarding deliveries or product information will be handled as soon as possible. Consequently, we cannot guarantee the usual delivery times. ETA for delivery will take longer than the regular ETA. It is capable of reading the fluorescence produced to indicate a sterilization process failure. The reader is very easy to operate. With automatic reading of indicator results, it is easy to identify where the sterilization conditions have been met or otherwise. An audible alarm sounds and the positive red light illuminates when a positive result is detected. An alarm also sounds if a 3M Attest Rapid Readout Biological Indicator is removed from the reader before final results have been detected.We do not have the ability to test this unit further. Strips and all other accessories are NOT included. Please see pictures for details!Buyers in Alaska, Hawaii, and all other countries will be invoiced for additional shipping costs. Please contact the seller for a shipping quote and any other questions you may have. Thank you.Sign up now. Programmable Microcontroller Dependability: The US AutoFlow is run by a programmable microcontroller that samples input sensors, sets control outputs, makes corrections through the use of fuzzy logic, and displays status on the control panel. Ultra Smart (US) 'Fuzzy Logic' provides quick, accurate, adaptive control of all the incubators parameters: chamber temperature, humidity and door temperature. Fuzzy logic tolerates environmental changes and component variation. It continually adjusts and improves to provide a 'living', exceptionally stable chamber environment. Relative Humidity Display and Control: The US AutoFlow NU-4850 has a relative humidity display and control system. The system controls from ambient to 95 relative humidity. Clear and Complete Information: Chamber Temperature, set point and actual Output and Alarm Status Water Jacket, low water level warning Chamber Door Ajar Tank Status System Alarm Condition Status Humidity, set point and actual HEPA Filtration System: The US AutoFlow employs two separate capsule HEPA filters to minimize potential contamination problems within the chamber. After a door opening, the internal recirculation system will return the chamber to better than Class 100 air quality within 30 minutes. 1' access port on right side The following link provides additional information from the instruction manual or original manufacturer's brochure. Images, specifications and description refer to the item as it was when new. Right-click to open the PDF in a new window or download it. And much more. Balances, baths, blenders, centrifuges, chart recorders, freezers, fume hoods, furnaces, glassware washers, glove boxes, mixers, moisture testing, ovens, pumps, shakers, vacuum equipment, water purification. And much more. Anaerobic incubators, autoclaves, blood testing, cell counters, CO2 incubators, cryostats, electrolyte analyzers, electrophoresis, glove boxes, microtomes, sterilizers. And much more. 3M Attest Rapid Readout Baths, calorimeters, color measurement, density meters, flash point, hydrogenators, oil testing, penetrometers, surface tension, vapor pressure, viscometers and rheometers. And much more. Stability chambers, tablet disintegration, tablet dissolution, tablet hardness, V-blenders. Jumper pins 1 and 2 of jumper J5. Jumper bottom 2 pins of jumper J6. Talk Monitor Level. Jumper left 2 pins of jumper J9.If customer desires, jumper right 2 pins ofJumper CRFT 2 pins when using a C1060Jumper right 2 pins for all configurationsSWT Threshold (High). SWT Threshold (NRML). Function. Menu Sign with Separate Speaker and. Microphone. Jumper Settings. Jumper pins 2 and 3 on jumpers J1 and J2. Lane 1 System. Jumper pins 1 and 2 on base station 1,Lane 2 System. Jumper pins 2 and 3 on base station 2,Air Switch (Pulse) Detector. Jumper pins 1 and 2 of jumper J4.Duplex Operation. Menu Power SelectionJumper pins 2 and 3 of jumper J4. Jumper pins 1 and 2 of jumper J5. Jumper bottom 2 pins of jumper J6. Talk Monitor Level. Jumper left 2 pins of jumper J9.If customer desires, jumper right 2 pins ofSelect a channel that neither receives or causes interference and then program the headsets to that channel usingImportant. After making any changes to the base station jumper settings, you must pressImportant. When two systems are used in a dual lane application, each base station mustIf you are installing this as a single lane system, 8 channels on the LANE 2 setting are alsoFigure 13. Base Station Circuit BoardRepeat the channel selection procedure if interference occurs. After seven channel changes, the original channelIf interference is still present and the system is a single lane system, try changing the. J3 lane designation jumper from lane 1 to lane 2. If this fails and none of the channels are interference free,Setting Audio Levels. To set the audio levels, refer to the related audio level procedure below and to the illustration of the base stationAll the audio level adjustment controls are located on the base station circuit board.The microphone at the menu sign must be located within four feet of the vehicle for duplexTo set the audio levels:Then turn the MENU MIC SENS level control down (CCW) until the feedbackVerify that feedbackIf everything is all right, the audio will be too loud.Duplex and Standard Systems. For Duplex systems, the microphone at the menu sign must be located within four feet of theThe following procedures apply to both duplex and standard systems. Alert Tone Level. The alert tone level is the volume of the alert tone heard in the headset. To set the alert tone level:When the vehicle is detected, you will hear the vehicleMonitor Speaker Volume Levels. The monitor speaker volume levels are the levels for the various functions heard through the optional monitorTurn the controls clockwise toTo set the monitor speaker volume levels:Adjust the MON TALKAdjust the MON PAGE control soIf any monitor functions are not desired by the customer, turn the related adjustment control fullyStandard Systems Only. The following procedures apply only to standard systems. Listen Level (Menu Sign Microphone Sensitivity). The listen level is the volume of the menu sign audio heard in the headset. To set the listen level:When the vehicle is detected, you will hear the vehicleThe Listen Level should now be properly adjusted.To set the menu sign talk volume level:Figure 14. Base Station Circuit Board. Jumpers. J1 and J2. Set for the type of menu sign in the system. Jumper pins 1 and 2 on both jumpers for menuJumper pins 2 and 3 on both jumpers for menu signs having aJumper pins 1 and 2 to select lane 1. Jumper pins 2 and 3 to select lane 2.Jumper pins 1 and 2 for an air switchJumper pins 2 and 3 for standardThis setting may cause feedback when a headset is operating near the monitorThis jumper is used to change the dynamic gainIt should normally be set to NRML. Occasionally, the inbound audio volume will decrease when C1060 headsets are used in Talk. Lock mode. Set jumper J10 to HIGH, in this case only. C1060 headsets are being used in Talk Lock mode. Important. After changing any jumper setting(s), be sure to press the RESET SWITCH onAdjustment ControlsControls the audio level coming from the menu sign.If any of the monitor functions are not desired by the customer, turn the appropriate adjustmentIndicatorsLit LED indicates which channel is selected for base station operation.Lights when a vehicle is detected at the menu sign.CHANNEL SELECT Switch. Programming Jack. RESET Switch. Controls power to the base station. Selects volume for day or night operation.Press to turn noiseSelects base station operating channel. For programming new channel selection or jumper setting(s) into theConnectors. C5000 Terminal StripNormal use and care of the system. Use and care of the headset. Battery replacement and recharging. Operation of the base station module switches and controls. Operation of optional Noise Reduction Module. Operation of Loop Detector. Refer to the Model C1060 Headset Intercom System Operating Instructions. Troubleshooting Audio Feedback. If audio feedback occurs, check the following and correct as necessary. Is the microphone audio wiring separately contained in its own cable, with no other “active” wires in theAre the speaker and microphone at least 14 inches apart? Is the outbound audio level too high? Is speaker audio being reflected back to the microphone from nearby surfaces? Technical AssistanceFood Service BusinessFood Services BusinessSt. Paul, MN 55144-1000. Printed in U.S.A.PDF Version: 1.3. Linearized: No. Create Date: 2003:10:29 15:18:01-06:00. Modify Date: 2003:10:29 15:18:01-06:00. Page Count: 29. Creation Date: 2003:10:29 21:18:01Z. Mod Date: 2003:10:29 21:18:01Z. Producer: Acrobat Distiller 5.0.5 (Windows). Author: US038009. Metadata Date: 2003:10:29 21:18:01Z. Creator: US038009. Title: Microsoft Word - C1060Ins.doc. We are taking extra precautions and following the recommendations of the CDC to ensure the safety and wellbeing of all our team members. Naturally, we want to help you do the same for yours. We are ready to help keep your drive-thru running smoothly, efficiently, and safely. Thank you for your continued business and allowing us the opportunity to serve you and your teams. Our technicians thoroughly check, repair, and upgrade to ensure like-new operation. Your purchase of these products includes a 4-month warranty. Please note that all refurbished items are subject to equipment availability. Advance Exchange Available. If not, proceed to program the C960 or C1060 headset. If all headsets fail to program or experience static, the base station may need to be replaced. Re-insert the power supply and allow the base station to initialize. Re-program all headsets to the new channel. Re-insert the power supply and allow the base station to initialize. If this is ON, toggle it to OFF. Re-insert the power supply and allow the base station to initialize. If this is ON, toggle it to OFF. Re-insert the power supply and allow the base station to initialize. If this is ON, toggle it to OFF. Verify that all wires on the phoenix connectors are docked securely. Re-insert the power supply and allow the base station to initialize. If this is ON, toggle it to OFF. Please do not factory reset a G5 base unless you are conferenced in with 3M on the line as they may end up giving you the code to enable both lanes or they'll replace the base. If the issues persists on the same communicator after testing all clean and charged batteries, proceed to replace the affected headset. If the green indicator light flashes briefly and then goes solid, registration is complete. If the issues persists on the same communicator after testing all clean and charged batteries, proceed to replace the affected headset. Press the ENTER button. Press the ENTER button. When the green indicator light stops flashing and goes solid, the headset is successfully registered. Remove any HS that are no longer in use (if the registration list is completely full). Make sure to hit the enter key on each space where a headset was removed, make sure you soft reset of the base station after the entries have been deleted. Attempt registration of headset after. The headset light should flash red and turn off. You can then attempt registration once more. Change NO to YES and press ENTER on next screen to restore the base to default settings. Clean contacts with an eraser or alcohol swab, if needed. Remove the battery from the assembled headset. A new message at the bottom of the screen should display if done correctly. One at a time, insert the battery back into the headset while watching the LED on the headset. Repeat powering on units until all have been registered. From the registration menu, select option 3. Change NO to YES and press ENTER on next screen to restore the base to default settings. Clean contacts with an eraser or alcohol swab, if needed. Page Count: 4 System Requirements The 3M A125 Noise Reduction Module requires a 3M model C921BA or C922AA Base Station. Installing the Noise Reduction board into the 3M Base Station 1. Remove the right-hand and left-hand top covers from th e 3M base station. Plug the A125 ribbon cable onto connector J8, located at the top of the left side of the circuit board. Be careful to support the rear side of the base station ci rcuit board when plugging in the A125 ribbon cable. 3. Position the holes near the edge of the A125 circu it board over the plastic standoffs on the base station. 4. Attach the left-hand base station cover after confi guring the A125 board, and performing the Final Checkout Procedure. Install the A125 board here Figure 1. Mounting the A125 to the C921BA Base Station The wider ribbon cable plug(s) are too wide to fit into the blue 20-pi n base station receptacle. The receptacle on the wireless base statio n board must be trimmed and the end s opened. Use a sharp razor knife and make four vertical cuts. Fold the ends of the blue receptacle down as shown below. Caution - Be careful to not cut any com ponents or circuit traces on the base station circuit board. Caution - Be careful to pull only on the ribbon connector plug. Pulling on the ribbon cable itself may cause it to separate from the plug. Instructions for trimming and open ing the base station receptacle: 1. Make a vertical cut at each corner of the blue 20-pin receptacle on the base station circuit board. 2. Fold the short end sides down as shown 3. Carefully insert the ribbon cable p lug(s) into the blue receptacle. Th e locking tab will not engage and should not be a problem. Noise Reduction: When DIP Switch number 1 ON the inbound microphone voice signal is digitized. On digitized, the noise is digitally removed from the voice by the digital signal processor and converted back to an analog voice signal. The analog voice signal is then sent to the m icrophone input of the intercom. When DIP Switch number 1 is OFF the inbound m icrophone voice signal is digi tized and converted back to an analog voice signal without removing any noise. The analog voi ce signal is then sent to the microphone input of the intercom. Echo Reduction: Used to reduce echo for full-duplex intercom configurations. Turn Echo R eduction OFF for half-duplex intercom configuration. When DIP Switch num ber 3 is ON, the board i s set for truck stop noise reduction level. This provides approximately 6dB m ore noise reduction with slightly more voice dedegration. Hi Frequency Equalization: When DIP Switch number 4 is ON, the higher end frequencies are increased by 3dB. This should be set to the customer’s preference.The LED can be off, blink at defined intervals, or be constantly lit. Table 3 illustrates the status indicated by the LEDs. The red LED should bli nk slowly.