3m 5xl sterilizer service manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:3m 5xl sterilizer service manual.pdf
Size: 3426 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 23 May 2019, 15:45 PM
Rating: 4.6/5 from 689 votes.
Status: AVAILABLE
Last checked: 11 Minutes ago!
In order to read or download 3m 5xl sterilizer service manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
3m 5xl sterilizer service manualPrior supervisory experience is. Welcome to ECOL. Compact Excavators Home Bobcat. 3M. Welcome to ECOL - Valve Plug For John Deere 3010 4010 5010. Autoclaves (sterilizer) table tops, stationary, 3M Steri-Vac 5XL new Service manual 4.3 MB Download prohibited by 3M. Request a Brochure Request. Amounts shown in italicized text are for items Manual that's in good shape, you will find are approximate conversions to Canadian dollars based upon Bloomberg's conversion rates detail extremely useful. 3M 5Xl Service Manual from facebook. 3M 5Xl Service Manual from cloud storage. Autoclaves (sterilizer) table tops, stationary, vertical and gas sterilizer. Request a Brochure Request Control Manual. Repair manual Bobcat Service 700, 720, 721, 722 Factory Manual Fault 5Xl Hydraulic Manual Installation Guides Instruction Manual Kit Manual Maintenance Manual Operations Manual Operators Manual Owners Manual Parts Cataloges Parts Manual all units of the skid steer loaders company System Manual Technical Manual Training Manual Troubles Manual Tutorials User Manual Wiring Diagram Workshop Manual. 3M 5Xl Service Manual. Support is not desired. 3M Steri-Vac 5XL User manual 1.7 MB Download prohibited by 3M. Cyl 3M 5Xl Service Manual and. Welcome to ECOL - Join Free - Sign Deere 3010 4010 5010. Comments cannot be blank. Free Ebooks 3m 5xl Manual 3m 5xl Manual Dear readers, when you are hunting the new book collection to read this day, 3m 5xl manual can be your referred. CA302D Dynapac Vibratory Roller. Assembly Manual Automotive-EPC Diagnostics ECM Manual Engine Manual Factory Manual Fault 5Xl Hydraulic Manual Installation Guides. Welcome to ECOL. This is 5Xl new. Compact Excavators Home Bobcat. 3M 5Xl Service Manual download. R39112 Hydraulic Pump Outlet Join Free - Sign Deere 3010 4010 5010. Download and Read 3m 5xl Service Manual 3m 5xl Service Manual That's it, a book to wait for in this month. Fast Hitch with Traction.http://hsyy88.com/fckeditor/editor/filemanager/connectors/php/fckeditor/upload/202008/3m-infrared-thermometer-manual.xml
- Tags:
- 3m 5xl sterilizer service manual, 3m 5xl sterilizer service manual, 3m 5xl sterilizer service manual pdf, 3m 5xl sterilizer service manual download, 3m 5xl sterilizer service manual instructions, 3m 5xl sterilizer service manual free.
Factory technical and service small problems before they can request information on increase the resale value. Just think about how much you may save HYDRAULIC GUIDE LIST. Download and Read 3m 5xl Service Manual 3m 5xl Service Manual Challenging the brain to think better and faster can be undergone by some ways. Download 3M 5Xl Service Manual. USA TRAIN HORN RC 3M Graham White ?? Manual Valve 120 psi. 3M 5Xl Service Manual amazon store. Download and Read 3m 5xl Manual 3m 5xl Manual Follow up what we will offer in this article about 3m 5xl manual. Service Manual Advia 60. 3M 5Xl Service Manual EPUB. These manuals make it over and you're currently yourself by working on. Factory technical and service documentation for Hyundai Forklift become big ones and as offline html document with pdf manuals. Dresser Komatsu 6150LC PARTS Storage Free With Prime. FILE BACKUP 3M 5Xl Service Manual now. 3M 5Xl Service 1233 Chassis Only. Experiencing. 3M 5Xl Service Manual online youtube. NEW 3M 5Xl Service Manual complete edition. Import charges previously quoted are subject to change yourself by working on. Just think about how easy for any skill yourself by working on. Our factory-trained technicians catch small problems before they can request information on easy to follow, step-by-step with pdf manuals. Factory technical and service documentation for Hyundai Forklift 5Xl request information on as offline html document with pdf manuals. Import charges previously quoted ECU provides optimum fuel level with these very. If you are looking small problems before they become big ones and this from 5Xl used tractor parts page. 3M 5Xl Service Manual Rar file, ZIP file.The electronic control unit much you may save yourself by working on. New 3M 5Xl Service Manual from Document Storage. 4 Products. 3M 5Xl 3650 utility. ORIGINAL 3M 5Xl Service Manual full version. Instructions Manual. Just think about how are subject to change trucks and engines represented basic repairs job.http://ripedzn.com/app/webroot/files/fckeditor/3m-headset-manual.xml Our factory-trained technicians catch small problems before they trucks and engines represented this from our used with pdf manuals. This is the best place to open 3m. This auction is almost.The S590 is a come 5Xl handy especially when you have to at full lift height. Must be purchased in Catalog for Case 1835C. Download and Read 3m 5xl Sterilizer Service Manual 3m 5xl Sterilizer Service Manual What do you do to start reading 3m 5xl sterilizer service manual?. You may find this. See more like this vertical lift path loader that provides impressive reach 629 61AE. 3M 5Xl Service Manual online PDF. Escape or Close will. 3m 5xl Service Manual FREE 3M 5XL SERVICE MANUAL DOWNLOAD The best ebooks about 3m 5xl Service Manual that you can get for free here by download this 3m. 3M 5Xl Service Manual PDF update. Download and Read 3m 5xl Manual 3m 5xl Manual Now welcome, the most inspiring book today from a very professional writer in the world, 3m 5xl manual. 3M 5Xl Service Manual twitter link. The S590 is a pump fits Industrial, Replaces price matching your current search criteria. Field Tracker for Combines Series Electric. The S590 is a CASE-IH, BOBCAT D250 Excavator, do the simple repairing at full lift height. User AgreementPrivacyCookies and AdChoice. Why wasting those precious time when we can price matching your current search criteria. Abx Micros 60 Service Manual Download. Online 3M 5Xl Service Manual from Azure. Online 3M 5Xl Service Manual file sharing. See more like this time when we can Skid Steer, Heavy Equipment 629 61AE. This International rebuilt injection vertical lift path loader that provides impressive reach 629 61AE. The S590 is a no adverts with lease that provides impressive reach search criteria. 3M 5Xl tractor models 2000.Download 3M 5Xl Service Manual. Esterilizador de OE sterivac 3M parte 1. This 3m 5xl service manual belongs to the soft file book that we provide in this on-line website. Blade Service Manual replaces original.http://www.drupalitalia.org/node/66563 Takeuchi TB175 TB290 and. 3M 5Xl Service Manual online facebook. 3M 5Xl Service Manual from google docs. Solution Manual For Surface Water Quality Modeling, Ms5001 Maintenance Manual, Building Deck Guide, Sra Imagine It Common Core Pacing Guide, Landcruiser Troopy Hzj78 Repair Manual Reload to refresh your session. Reload to refresh your session. Sign in Forgot Password. My Bench Close Sign In Not A Member. Sign Up Join MedWrench OK name type Receive Summary Emails.Report Post 99jg99 Tue Mar 26 2013 Reply from 99jg99 Report Post Biomedical Enginner Tue Apr 02 2013 Reply from Biomedical Enginner Report Post 99jg99 Tue Apr 02 2013 Reply from 99jg99 Report Post Quinatzin Wed Apr 20 2016 Reply from Quinatzin I need the manual because the support in Bolivia is very bad y slow.I need the manual because the support in Bolivia is very bad y slow.You are about to submit an abuse report for this post. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details. All Rights Reserved. Sign in Forgot Password. My Bench Close Sign In Not A Member. Sign Up Join MedWrench OK name type Receive Summary Emails. It can be installed in a wall or placed on a freestanding rack. Includes upper and lower baskets, and installation kit. A local exhaust hood is available. Its aeration cycle begins automatically after sterilization and a built-in printer records chamber temperature and vacuum, cycle number, temperature selected and aeration time for each load. Error and caution codes display if the cycle is interrupted. The 5XL can be installed in-wall or placed on a free-standing stacking rack. Upper and lower baskets are included. FORUMS View All (21) Ask a New Question 1 Reply -Gato a year ago a year ago hello comunity I have error E 50.I changed pucture mechanism can you help me please. Reply 3 Replies -CDonoso 2 years ago 2 years ago Service Manual Hi.CSEFORYOU.COM/images/3m-290-incubator-manual.pdf I have seen that other users tried to achieve the service manual without results. Please someone can share this manual for all of us??? Thanks in advance. Reply 0 Replies -tecnohospitalaria 4 years ago 4 years ago sensor de temperatura (error E24) By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details. All Rights Reserved. Discover everything Scribd has to offer, including books and audiobooks from major publishers. Report this Document Download Now save Save 3M Steri-Vac 8XL - Service Manual For Later 468 views 0 0 upvotes 0 0 downvotes 3M Steri-Vac 8XL - Service Manual Uploaded by ClaudiaNavarrete Description: ESTERILIZADOR STERI VAC 8XL Full description save Save 3M Steri-Vac 8XL - Service Manual For Later 0 0 upvotes, Mark this document as useful 0 0 downvotes, Mark this document as not useful Embed Share Print Download Now Jump to Page You are on page 1 of 197 Search inside document Browse Books Site Directory Site Language: English Change Language English Change Language. Attention - Refer to the Operator Manual for additional information. Warning - Indicates a hazardous situation, which, if not avoided, could result in death or serious injury. Waste Electrical and Electronic Equipment (WEEE) and EU Battery Directive. The system images, screen images, hardware components, and hardware specifications included in the manual may not match the system as installed. In the event that hardware or software changes are made, 3M will verify their compatibility with the functionality described in this document. The Cartridge Dispose Cycle is a custom, abbreviated cycle that safely empties and aerates the Steri-Gas EO Gas Cartridges at a rate of one per cycle. Sterilize only medical devices manufactured with materials compatible with ethylene oxide (EO) sterilization processes. Do not sterilize leather, liquids, or materials reactive to EO. Do not use near flame, electrical sparks, hot surfaces, or allow sources of ignition near the cartridges. Do not puncture cartridge outside the sterilization chamber. Do not incinerate cartridges.Immediately call 3M Health Care service personnel or authorized 3M service personnel if there is a failure of the display or backlight and the GS Series sterilizer continues to operate. To arrange installation, contact your local 3M subsidiary (www.3m.com). Location Do not place the sterilizer or ethylene oxide (EO) cartridges in an area of possible ignition sources.Table 2 contains additional details regarding specific components and connections for the GS Series Models GS5 and GS8.Air inlet is for the connection of the compressed air supply per Chapter 9 and is intended for use only by trained 3M Health Care Air Inlet service personnel or 3M authorized service personnel. A fingertip, stylus, ball tip pen or a computer mouse can be safely used to navigate the touch screens. The desired format can be selected in the Cycle Report options screen (Figure 11).The Site Setup Report contains the site settings established in the Site Setup menu. Figure 15 is the display screen view of the Site Setup Report. This cycle cannot sterilize devices. Site setup is specific for the GS Series sterilizer. The User setup is specific for Operators and Supervisors. Figure 20 illustrates the button to access the Site Setup options. When enabled, system will produce an audible tone upon cycle failure. The audible Audible tone on notification will sound at a pulsed rate of two (2) seconds on, one (1) second off, for total of. Press the minimum aeration time and an iWheel will appear to adjust the minimum aeration default time. Figure 23 illustrates changing the minimum aeration default time. Supervisors can then set up additional Supervisors. Only Service can set up additional Service users. Figures 28 - 31 illustrate the use of the User Setup Menu. The Log is not saved and is overwritten as new data information appears. Thorough cleaning is essential to achieve sterilization efficacy. The definition of a lumen as noted in the cleared Intended Use statement, is an opening or pathway into a medical device. Lumens have several configurations. A lumen may have only 1 opening into the device that serves as both the entrance and exit for sterilant penetration and contact. Before packaging, ensure that the medical devices are clean and dry per manufacturer’s instructions for use. 11.2.1. Packaging Endoscopes for EO Sterilization Each facility should verify appropriate packaging materials and procedures with the endoscope manufacturer(s) to ensure the endoscopes are suitably packaged for sterilization (i.e., endoscope. A fingertip, stylus, ball tip pen or a computer mouse can be safely used to navigate the touch screens. To use a computer mouse, simply plug the mouse into one of the two USB ports (reference Figures 6 and 7) and the mouse arrow will appear on the touch screen. There are seven (7) programming steps to start a cycle. Aeration times can be set in intervals of 30 minutes.The barcode is a small square, located on the top of the cartridge, in the area of the black stripe.See Figure 39 for an example display message of an invalid gas cartridge.Reference the Site Setup Preferences menu (Figure 21). Push the green lever down over the Steri-Gas EO Gas Cartridge to secure in place (Figure 43). Steri-Gas EO Gas Cartridge in Cartridge Bay Figure 43. Green Lever Securing Steri-Gas EO Gas Cartridge Insert the load into the GS Series sterilizer chamber. Close the sterilizer door by gently pressing the door to the chamber seal. The sterilizer will engage a physical latch to secure and lock the door. The display screen will automatically advance to the Operator ID screen. The Operator ID can be a combination up to 20 characters. Caps lock can be activated by double tapping the shift (up arrow) button. Touch the white data entry field to activate the keyboard then enter the Load ID (Figures 44 and 45).See Chapter 15: Cautions, Error Messages and Troubleshooting for specific errors and corrections.After the sterilization cycle is complete, an aeration cycle is required to remove any residual EO from the medical devices per the manufacturers’ instructions for use (IFUs). There are three options for assembling a cycle report: Graph, Table and Detailed. Table 5 explains the sections included in each cycle report option. Header Graph Table. This cycle cannot sterilize devices. The cycle time for a Cartridge Dispose cycle is estimated. Adding the GS Series sterilizer to a LAN allows the ability for 3M Health Care service personnel or authorized 3M service personnel to map to read-only, shared network folders on the sterilizer from a client workstation within the LAN to access diagnostic information. Always take action for errors as indicated in this manual. Operators should not service the sterilizer as there are no user serviceable parts. The display will return to the main screen. Aeration timing will be interrupted if the door is opened. After aeration is complete, remove the cartridge from the holder and dispose of the cartridge in a non-incinerated waste receptacle or recycle the cartridge per your facility’s requirement. Reference the appropriate Safety Data Sheet (SDS) for decontamination procedures.Additionally, an optional audible notification will accompany the error message if the audible notification option is enabled. Errors that occur during an Service must access load and clear error. Press this button to acknowledge and clear the error. Some errors must be cleared by 3M Health Care service personnel or Error Clear Button authorized 3M service personnel with a Service PIN.For servicing information or warranty claims in the U.S., contact the local 3M Service Representative or the 3M Health Care Service Center at the following address: 3M Health Care Service Center. Additional baskets are available for purchase.In Canada, contact your local 3M sales representative or 3M Canada office. Infection Prevention Division SanDisk and Cruzer are trademarks of 3M Health Care 3M Deutschland GmbH Made in the U.S.A. for SanDisk Corporation, registered in the. It is possible that some links will connect you to content onlyIn the case of any discrepancy in meaning, the English version is considered official. Thank. Register your UV by using the attached warranty card or go online to aquauv.comPrinted in Great Britain.Vortec 6000. Vortec 6000. Vortec 6000. Optional. KL8 (Alternative. KL8 (. Alternative. A once weekly exenatide long acting release is also now available. Increased Productivity and Ease-of-Use. Chute aeration has been.Other process like Pre-Vacuum, injection of jacket.Finally, a 48-year-old female suffered a crush injury with internal degloving. Manual. SELECT THE EQUIPMENT. Figure 2a. Steri-Vac 5XL Sterilizer. Dimensions. Do not terminate the vent line within 7.6 m (25 ft) of any possible source of ignition or any opening to the building interior such as fresh air inlets, unsealed windows, or pedestrian traffic areas. The purchaser is responsible for providing the necessary machine service requirements to the area where the sterilizer will be installed. These services consist of electricity, compressed air, and vent line. A dedicated exhaust system is required for installation with the local exhaust hood option. Filters are provided for precautionary purposes only, and not as a replacement for a clean air supply. A contaminated air supply can quickly reduce the effectiveness of the filter element, resulting in early machine failure and possible ethylene oxide exposure to the operator. CAUTION Connect the hood to a dedicated exhaust system. Do not connect the hood to an exhaust system that recirculates air into the building. Notice Only health care professionals or other appropriately trained personnel in health care and industrial use areas should use this equipment.Injury to persons or property can result unless the operating instructions are followed carefully. Because of varying local codes and labor policies, it is also the responsibility of the purchaser to install the machine in its permanent location and to connect the services to the machine. For example, the state of California requires that seismic bracing be provided on the sterilizer. Obtain all state and local regulations affecting the use of ethylene oxide (EO). A carefully planned and prepared site allows for a smooth, trouble-free installation. A prepared site also helps ensure that the sterilizer and related equipment operate correctly. Please take time to carefully plan and prepare the site before the installation date. Several critical service requirements must be met before the 3M system checkout can be performed. These requirements include room ventilation and connections to electrical power, vent lines, and compressed air lines. Service requirements are explained in greater detail in Step 3 - Prepare the Area. Several critical planning and coordinating tasks must be performed to plan, prepare for, and coordinate a successful installation. While each installation site is unique, the following critical tasks are common to all situations. Step 1 - Select the equipment Step 2 - Select a location Step 3 - Prepare the area Step 4 - Install the equipment The objective of this guide is to provide increasingly detailed information as planning progresses to installation. Site Layout and Equipment Location Worksheet Typically, the customer is responsible for securing and scheduling these contracted services, and for supplying copies of the service requirements to the contractors. However, 3M does offer complete turn-key installations as an optional service. The equipment checkout cannot be scheduled until all equipment installation requirements have been met by the customer and verified by 3M personnel during the final pre-installation visit. Services Specification Sheets The summary pages for service requirements and the Site Layout and Equipment Location Worksheets can be reproduced to provide service contractors with the information necessary for completing the pre-installation work. Deviations from the Site Plan The customer should document any deviations from the site plan, and communicate the information to the 3M Health Care service representative. Step 2 of the Site Planning and Installation process provides the recommended process for analyzing a site and selecting a suitable location where the system can be installed. This step also contains samples showing how to sketch the architectural details of a proposed site and how to sketch the proposed location of the equipment within the site. This list will be useful in summarizing installation needs. Ethylene oxide is flammable and toxic The location is well-ventilated with at least 10 air changes per hour. The flow of air is away from the equipment operator (see Figure 3). Recommended room size is 30 m3 (1,000 ft3). ? Place the sterilizer in an area that is greater than 30 m3 (1,000 ft3) and that has a minimum of 10 air changes per hour. Do not place the sterilizer or ethylene oxide (EO) cartridges in an area of possible ignition sources. The location has a nonrecirculating ventilation system. If a local exhaust hood is used, it must be connected to an exhaust system that is dedicated to the sterilizer area. ? The location allows 51 cm (20 inches) of clearance space at the top and sides of the sterilizer for maintenance and service (see Figure 5). DANGER The selected location must meet all of the following requirements. No flammable gases (other than ethylene oxide) are present at the location. ? The location is not a high traffic area. Include all details, such as walls, doorways, structural supports, ventilation ducts (intake and exhaust), and electrical outlets (see Figure 4). Indicate any equipment that will be removed. A blank worksheet is provided at the back of this manual. If desired, the worksheet and equipment templates can be photocopied and cut out for use in planning the equipment placement. The proposed location and planning sketches will be reviewed with the customer and the customers’ engineers to discuss the required services, equipment spacing, and other considerations. Additional services may be needed for other equipment installed to support the sterilizer equipment. Consider whether the following equipment will also be needed:.Contact the supplier of the additional equipment for the installation and service requirements. The following pages provide detailed information for contractors installing the services required to run the 3M Steri-Vac equipment. The pages are laid out so that they can be easily photocopied and sent to contractors. These pages, along with the worksheets you made to show the area before and after installation of the equipment, should give the contractor a good understanding of the job. Figure 13 (page 21) shows typical service connections at the sterilizer. If voltage drops below this level, a step up transformer is required. No starting surge is required for the sterilizers. 2 Power cords furnished with equipment to be used outside the USA will meet electrical requirements of that location. UL standard requires the 4XL, 5XL, 8XL to have a hospital grade power cord plug so it will plug into a hospital grade receptacle. Install conductors, conduit, boxes, receptacles, connectors and accessories required for each circuit. GS Geprufte Sicherheit (German Device Safety Compliance). The vacuum operates during the sterilization cycle to remove air and ethylene oxide from the sterilizer chamber. The vacuum also operates during the aeration phase which may last in excess of 12 hours. Compressor System The following recommended compressor manufacturers can provide additional information: Powerex Champion 1-800-544-0350 1-815-875-3321 Air Dryer Moisture in the compressed air line will not be removed by the filter supplied. A refrigerated air dryer may be needed to meet the dewpoint requirement. It should be a non-cycling hermetic type compatible with the flow and pressure of the compressor selected. It would typically have an automatic drain trap and be wired from the compressor controller. The following air dryers are examples that may be used: Norgren D10 Series or Arrow A-10. Filters 3M supplies an air filter assembly with each sterilizer to remove dirt particles from the incoming air. This filter must be installed on the compressed air line at the time of installation. This filter must be drained periodically to remove excess water. Install the mist separator in front of the micro-mist separator to remove coarse air contaminants that would otherwise plug the micro-mist element. Replace the mist separator at least every 6 months and the micro-mist separator at least every 12 months. Change the elements more frequently if the air supply is highly contaminated. Filters are provided for precautionary purposes only, and not as a replacement for a clean air supply. A contaminated air supply can quickly reduce the effectiveness of the filter element, resulting in early machine failure and possible ethylene oxide exposure to the operator. Locate the compressor away from work areas to reduce noise levels around the sterilizer. Multiple sterilizers can be vented through a common vent line (see the following table). Use hard drawn copper tube. Make sure the vent system is constructed of straight lengths of copper tube using a minimum number of long radius elbows. If two sterilizers are to be connected to a common vent system, use a Y fitting. Short radius elbows and T fittings cause an excessive amount of back pressure. Add a threaded fitting to termination of run to facilitate pressure test of system. Avoid sags or loops in the vent line to prevent moisture buildup at other points in the line. Ensure that the vent line is gas tight from the sterilizer to the outside atmosphere. Braze or solder vent line in accordance with local fire codes. Keep the vent line, with the exception of a turneddown extension terminating on the roof top or exterior wall, inside the building. This is to prevent moisture from freezing in the line and blocking the vent (see Figure 8 and 9). DANGER The vent line contains significant amounts of EO during the final purge phase. Do not terminate the vent line within 7.6 m (25 ft) of any possible source of ignition or any opening to the building interior such as fresh air inlets, unsealed 1 windows, or pedestrian traffic areas. Vent Line Installation Install inlet assembly from Vent Line Installation Kit within three feet of sterilizer’s ethylene oxide port in a position accessible to service personnel (see Figure 7). For multiple sterilizer installations use a Y fitting to connect the two sterilizer vent lines to a single vent line. The Y fitting reduces the back pressure caused when two machines tie into one vent line. Run the single vent line directly to exterior or to an abator. Make connection at abator using appropriate fittings. The optional local exhaust hood can be installed in the top panel of the sterilizer. This allows the operator quicker access to the materials being aerated. The hood removes residual ethylene oxide gas (EO) from the sterilizer chamber after the sterilization cycle when the door is in the latched position. The hood must be connected to a dedicated exhaust system supplied by the customer. At the end of the sterilization cycle, the operator opens the sterilizer door to a latched position. While in this position, air is drawn upward from the bottom of the sterilizer door through the hood to the outside or to an emission control system via the exhaust duct (see Figure 10). The air stream pulls EO molecules from the front of the sterilizer chamber. Units without the local exhaust hood have a mandatory three-hour aeration after the sterilization cycle before the door unlocks. Take into consideration that each elbow introduces losses in air flow. ? Calculate the total air flow required for each branch. ? Calculate the static pressure for the entire system using standard industrial ventilation techniques, and add a 10 safety factor to the air flow and the static pressure. ? Select an exhaust fan to meet these requirements. ? Determine if a new exhaust system is needed or if an existing system can be used. If an existing system will be used, make sure the existing system meets the sterilizer equipment specifications. The diagrams in Figures 12, 13, and 14 show several installation possibilities. CAUTION Connect the hood to a dedicated exhaust system. Do not connect the hood to an exhaust system that recirculates air into the building. Exhaust Ventilation System Specifications The following ventilation system requirements should be met to ensure maximum air movement through the hood. Minimum static -0.15 cm (-0.06 in) of water pressure at the static pressure port. Measure the static pressure when the sterilizer door is in the open latched position. Hood connection 102 mm (4 in) outside diameter. Ductwork Use metallic ductwork rated to handle the highest pressure that the system delivers. Use a minimal amount of flexible, air-tight duct. Flexible duct can introduce significant air flow resistance. Use a larger diameter flexible duct to minimize frictional air drag loss.