3ware 9650se user manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:3ware 9650se user manual.pdf
Size: 4473 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 15 May 2019, 22:20 PM
Rating: 4.6/5 from 709 votes.
Status: AVAILABLE
Last checked: 13 Minutes ago!
In order to read or download 3ware 9650se user manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
3ware 9650se user manualWe have 4 3ware 9650SE-4LPML manuals available for free PDF download: User Manual, Manual, Installation Manual Connect the Cables to the Controller Connect the Cables to the Controller Connect the Cables to the Controller Connect the Cables to the Controller Connect the Cables to the Drives Connect the Cables to the Drives or. Product Guide. August 2011. Table of Contents. Introduction to LSI.Page 3. As the world’s No. 1 provider of RAID controllers in the channel, our commitment to channel partners.Page 8 Advanced Software OptionsPage 11 3ware 9650SE Product LinePage 14 SAS SwitchPage 15 Solid State StoragePage 16 Cables and ConnectorsPage 18 3ware Battery Back-up UnitsPage 19 Committed to fulfilling all of your storage needs, LSI provides you with tools and. This publication may be copied or reproduced for reference purposes only. All other purposes require the express written consent of AMCC, 215 Moffett Park Drive, Sunnyvale, CA 94089.Table 1: Sections in this CLI Guide Chapter Description 1. Introduction to 3ware Installation, features, concepts Command Line Interface 2. CLI Syntax Reference Describes individual commands using the primary syntax There are often multiple ways to accomplish the same configuraMultiple 3ware RAID controllers can be managed using the CLI via a command line or script. Note: Some CLI commands are supported only for particular models of 3ware RAID controllers. Wherever possible, commands are labeled to indicate when they are supporteFor a summary of what you can do using the CLI, see “Common Tasks Mapped to CLI Commands” on page 19. Windows 2000, Windows XP, and Windows SeIf you are using 3DM, as opposed to 3DM2, AMCC does not recommend installing both 3DM and CLI on the same system. Conflicts may occur. For example, if both are installed, alarms will be captured only by 3DM. You should use either CLI or 3DM to manage your 3ware RAID controllers. This is not an issue for 3DM2. It can be installed with CLI.https://www.cmevalves.com/userfiles/canon-battery-grip-manual.xml
- Tags:
- 3ware 9650se user manual, 3ware 9650se user manual download, 3ware 9650se user manual pdf, 3ware 9650se user manual free, 3ware 9650se user manual downloads.
(3DM was an earlier veThe CLI prompt is displayed in a DOS console window. Installing the 3ware CLI on Linux and FreeBSD 3wareTo do so, simply enter the command and the arguments. Single commands can be useful when you want to perform a task such as redirecting the output of the command to a file. It also allows you to use the command line history to eliminate some typing.The disks may be attached to different ports than they were originally attached to, without harm to the data. For definitions of other terms used throughout the documentation, see the “Glossary”. Available RAID Configurations RAID is a method of combiningRAID 1 is also known as a mirrored array. Mirroring is done on pairs of drives. Mirrored disk arrays write the same data to two different drives using RAID 1 algorithms (see Figure ?). This gives your system fault tolerance by preserving the data on one drive if the other drive fails. Fault tolerance is a basic requirement for critical systems like web and database serverWhen drives are configured as a striped mirrored array, the disks are configured using both RAID 0 and RAID 1 techniques, thus the name RAID 10 (see Figure ?). A minimum of four drives are required to use this technique. The first two drives are mirrored as a fault toleranRAID 50 requires a minimum of six drives. Several combinations are available with RAID 50. For example, on a 12-port controller, you can have a grouping of 3, 4, or 6 drives. A grouping of 3 means that the RAID 5 arrays used have 3 disks. Ours seems dead. up vote 2 down vote favorite.AMCC 3WARE 9590SE user manual 9650SE) PN: 720-0145-00 October 2006 CLI Guide If you are using 3DM, as opposed to 3DM2, 9650SE RAID 6 Migrating Degraded Sign in to follow this.Warranty, Returns, And Additional Information. Warranty; Limited Warranty period (parts): 3 years; Limited Warranty period User Manual Driver Disk 4 x SATA Cable. Warranty, Returns, And Additional Information.http://domesticsolutionsagency.com/userfiles/canon-bj10sx-manual.xml Warranty; Limited Warranty period (parts): 3 years; Limited Warranty period Kfor weather radar for fsx, 2dz only drake, Suliana layang sworo remix, Sony ericsson w800, Wallpapers diwali special mithai. Reload to refresh your session. Reload to refresh your session. Trademarks. Contents of this Package.1 System Requirements.2 9650SE RAID Controller Card Models.4 Cables.7 Safety Information.10. Chapter 2. Installing Your 3ware RAID Controller.15. Online help is also available when you are using 3DM 2 (3ware Disk Manager). Additional support information is available in the 3ware Knowledgebase, at this website: This document, 3ware 9650SE Serial ATA RAID Controller Installation Guide 3ware CD-ROM with driver, software, and additional documentation Appropriate cables for the 3ware 9650SE modelDrive RequirementsFigure 1. 2-Port 3ware 9650SE-2LP Serial ATA RAID Controller. LED Connector Heat Sink. Ports: 0 (on top) 1 (on the bottom)LED Connector. Heat Sink. Ports: 0 thru 3. Slots for battery holder. BBU connector and hole for post. Figure 3. 8-Port 3ware 9650SE-8LPML Serial ATA RAID Controller. I2C connector. I2C connector LED Connectors Heat sink. Ports: 8 thru 11Holes for battery holder. Figure 5. 16-Port 3ware 9650SE-16ML Serial ATA RAID Controller. Cables. SATA Cables The 2-port 9650SE RAID controller uses standard SATA cables. Multi-lane CablesFigure 8. Multi-lane Cable Serial ATA (SFF-8087)Figure 9. Multi-lane M8 Cable (SFF-8087). Multi-lane M8 fanout cable. Safety Information. To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this information and observe all warnings and precautions in this guide before installing or maintaining your computer. Replacing the heat sink will alter thermal characteristics and cooling requirements and may cause the controller to fail. Replacing the factory-installed heat sink will void the warranty. Back up your data! Creating or deleting disk arrays destroys.https://skazkina.com/ru/bose-universal-remote-control-manual Note: If you are using a chassis that includes a Chassis. Control Unit (CCU), follow the instructions that came with the chassis to connect the I2C cable (Chassis Control Cable) from the CCU to the I2C connector on the 9650SE. When to install the drives. If the drives are not already installed in your computer, you can choose to install them either before or after installing the 9650SE controller. Before You StartPort 0 is on top. Port 1 is on the bottomStep 1 (Multi-lane Controllers). Connect the Cables to the Controller. The 4-port and 8-port cards will work in the x4, x8, or x16 PCI Express slots, while the 12-port, 16-port, and 24-port cards will work in the x8 or x16 PCI Express slots.Figure 13. Inserting Controller Into PCI Express Slot. Use a PCI Express slot for the 3ware 9650SE controller.Multi-Lane backplane. LED indicators for individual Overall LED drive status indicator: drives on J7: 0 and 1 (left to the last two pins of J7. The anode right) is the lower of the two pins and the cathode is the upper. Figure 18. 12-Port 3ware 9650SE-12ML Serial ATA RAID Controller. The anode is the lower of the two pins and the cathode is the upper.Table 2: LED Indicator Pin PositionsThe user guide is included on the 3ware CD that came with your controller. It is also available from the 3ware website at The 9650SE-2LP does not support the BBU. Caution: Both the 3ware RAID controller and the BBU are. Connector on the BBU mates to receptacle on the controller. Post on the BBU mates to post hole on the controller. Figure 21. Points of connection on the BBUFigure 23. Points of connection on the full-height controllerMate the connector on the BBU control module with the receptacle on the controller. Match the plastic post on the BBU with the hole on the controller. Figure 25. BBU control module ready to connect to the controllerFigure 26. BBU control module connected to the controllerFigure 27.http://www.decor-ada.com/images/bt-contour-200-payphone-manual.pdf Clips on the battery module hook over slots on the top edge of the half-height controller. Figure 28. Attaching the battery module to the half-height controllerInsert the clips on the top of the battery module into the holes on the controller. Figure 30. Attaching the battery module to the full-height controllerNote: The battery will 31. Battery power connector inserted in power receptacle. The controller is now ready to install in your system.Caution: There is a risk of explosion if the battery is replacedTo obtain a replacement battery module, contact AMCC. To do so, press down on the lever-like clip on the battery power connector and slide it out of the slot. (If desired, you can remove the BBU control module to facilitate disconnecting the power cable.)For detailed instructions, see the 3ware Serial ATA RAID Controller User Guide and the 3ware Serial ATA RAID Controller CLI Guide.Feedback on this manual. Your feedback is welcome. Please email us if you're running the latest version of your browser and you still see this message. The actual Open Box product may differ in packaging and included accessories, but has been tested to ensure basic functionality. Most customers receive within 5-9 days.Supporting RAID 0, 1, 5, 10, single disk, and JBOD, the 3ware 9650SE can not only backup data but can also extend the storage capacity of a system significantly. Providing S.M.A.R.T drive monitoring for status and reliability, hot swap and hot spare drive storage, the 3ware 9650SE is perfect for small to medium size businesses. Last but not least, the 9650SE supports a variety of operating systems including the following: Windows (XP, 2000, Server 2003), Windows x64bit, Linux and FreeBSD. Four SATA ports (Through Multi-lane Connector) support RAID Levels 0, 1, 5, 10, Single Disk, JBOD for better performance and reliability.ATA pass-through mode support SNMP support. Multiple card support within a system for large storage requirements.https://agribusiness.pk/wp-content/plugins/formcraft/file-upload/server/content/files/16291c4c25aafb---8753e-user-manual.pdf Hot-swap and hot-spare support for data availability. Dynamic sector repair for robust data protection. S.M.A.R.T. disk drive monitoring for reliability.No hang-ups, even for a first time RAID card user. Cables are very flexible and it really helps when setting things up. Card has more features than I need, and it's priced well.With write caching disabled, may as well be on dial up to transfer files. All tested with HD utilities from the server, not through the network. I hope it's just an issue with the WD Red drives- I expected more from a standalone RAID controller, even if it is a lower end unit than the commercial grade stuff many of the IT admins here use.I wish I had bought the card with two cable adapters so I could better implement RAID the configurations this product offers.Supported in FreeBSD and Linux kernels.Making sure firmware up to date is a must. But these are to be expected and are definitely not show stoppers.First with 4x WD Raptor in RAID10 -- great. Then 4x Hitachi 2GB in JBOD for FreeNAS -- great. Now 4x Intel SSD in RAID0 -- great!Never had a single hick-up.Four ports with memory caches for this price is incredible. Good performance.It looks like this is the same card as the 8 port, but would have one more port with another four connections on it.If you are using Windows it is tough to justify a more expensive card. If you are using Linux or VMWare you may want to pursue a major vendor card.Has performed flawlessly. Many of the other PC components including the motherboard have been replaced while the card just keeps on humming.I have had to rebuild the box due to a failed motherboard and a failed OS disk drive (not connected to the card). I've changed OS's 3 times (Win2k then Linux then Win2k8R2), swapped out 2 drives and re-partitioned the array once all without a hitch. In all this I haven't lost a single iota of data using this array.I have been running a RAID 5 array since 2010 using WD RE3 drives. Not one hiccup or any other issue.www.fotografiacantero.com/fotografia_userfiles/files/canon-es100-manual.pdf Email of alerts is a great feature since I am rarely at this site. The only alerts I have ever recieved was due to power failure before I could convince them they needed a UPS.Do so and you will be happy. Use a cheaper drive and you will not be so happy.It rebuilds arrays quickly and without a hitch.Click here for more details. Secure shopping made faster. Check out with PayPal. Any exceptions to the condition of the item outside the manufacturer’s information should be provided in the listing, up to and including warranty details. Any accessories MAY OR MAY NOT be included. Newegg will NOT send you any missing accessories, even if it is required to use all of the item’s functions.Open Box items usually do not come with manufacturer or vendor warranty or technical support. However, warranty support may be available if an item was never registered by a previous owner. Please contact the manufacturer to check. Product may includes warranty, and accessories found with the original product. Product may or may not be in the original packaging. Returned items with minor packaging defects fall under this category. Product does not come with warranty unless stated otherwise in product description. Product does not come with warranty unless stated otherwise in product description. Product does not come with warranty unless stated otherwise in product description. Functionality issues beyond signs of use should be disclosed in product description. Some manufacturers place restrictions on how details of their products may be communicated. Some manufacturers place restrictions on how details of their products may be communicated. Some manufacturers place restrictions on how details of their products may be communicated. Some manufacturers place restrictions on how details of their products may be communicated. Please try again.Labor free Back to SellerPlease try your search again later.You can edit your question or post anyway.http://frederickfollows.co.uk/wp-content/plugins/formcraft/file-upload/server/content/files/16291c4d175d48---8753e-service-manual.pdfLabor free Back to SellerIf you are a seller for this product, would you like to suggest updates through seller support ?Amazon calculates a product's star ratings based on a machine learned model instead of a raw data average. The model takes into account factors including the age of a rating, whether the ratings are from verified purchasers and factors that establish reviewer trustworthiness. I'm using I've in a WHS 2011 box with 20x2tb drives in a raid 6. I'm getting 120mb write speeds and it's only sata 2! And that's with 5400rpm drives!Sorry, we failed to record your vote. Please try again It sounds OK but. It sounds OK but, never being able to get cables for it after searching for days. Never.Sorry, we failed to record your vote. Please try again You can't go wrong. If you can't find the cables, get the 16 port version. Who's going to need 24 anyway. Highly recommended.Sorry, we failed to record your vote. Please try again. It provides controller, logical unit and driveUser can set the focus to aA logical unit can be a one-tier, two-tier, or three-tierRAID-1 and RAID-5 are examples of two-tier units and RAID-10 and RAID-50 are examples of three-tier unitsEach port can be attached to a single disk drive. On a controller such as the 9650SE with a multilane serial port connector, oneOn the 9690SA and 9750 controllers, connections The 9690SA controller A vport indicates the ID of a drive, whetherFor dual-ported drives, althoughThis is because the drive is Therefore, unless otherwise Note: The primary command syntaxThe following is a summary of the Messages, and descriptions and examples are presented for each object message For these, the command For the former please see Features sections. Messages are commands It may be a read operation such as for theAttributes are either Boolean Attributes or Named Attributes. Value of a BooleanValue of named attributes areNote that theMIGRATING, MIGRATE-PAUSED, RECOVERY, INOPERABLE, and UNKNOWN.http://oneself.pro/wp-content/plugins/formcraft/file-upload/server/content/files/16291c4d7a1823---8753es-programming-manual.pdf As example: For more information This command is active inRecall that messages (orThe concept is similar to being in a particular location in a file system andThe hostname is the name of With current releases, the Rescanning the controller will clear the error status Thus, unlike the older display, the Moreover, if there are no Summary would show an empty summary consisting of only the header. See other show sub-commands below. Release 9.5.1 or earlier: Release 9.5.2 or later: In the unit summary of the For example: An invalid attribute will terminate the loop. Possible attributes are: achip, allunitstatus, autocarve (9550SX and higher), Connections If the ondegrade If the ondegrade policy is off, a unit cache policy If the policy is on, allEach volume can be treated as an individual disk with its own file system. The default carvesize is 2 TB. For 32-bit OS users, it is recommended to keep the policy on unless users Display will also show the default Running Average, and ext for Extended Drive Statistics. More detailed See Shell Object Messages for more on Not. Optimal definition. By default the host Specifying One or more ports can be specified. Multiple. For example. The followingAt the most bottom layer. N number of disks per group are used to form the RAID-5 layer. These. RAID-5 arrays are then integrated into a RAID-0. This attribute allowsValid valuesHowever given 12 disks, specifying 3 will create four RAID-5 under the RAID-0 By default CLI will inform the OS. One application of this feature is to avoid Enabling the write cache increases performance at No caching is recommended when no BBU or UPS If a BBU or. UPS is not installed, to avoid possibility of data loss in the event of suddenThe rdcachebasic For more details on this.forwardparcel.com/userfiles/files/canon-es-800-manual.pdf For the 9650SE, For other 9000 series controllers Keep in mind however, that That is, for For the spare unit, drive queueing is not meaningful and the qpolicy cannot The following table illustrates the supported No space is allowed within the string. If user likesUser can change the name of the unit This is a feature for 9000 or above series ofThe value(s) should beZero (0) is an invalid LUN Note that thereRapid RAID Recovery can speed up the rebuild This feature allows for expedited boot-up time in the event of an unclean Setting it to rebuild applies the If the policy is set to disable, then Also, once disabled, that setting could not be In addition. Rapid RAID Recovery is not supported over migration. Any newly found unit(s) or drive(s) will be listed.Default is to inform If a failure (suchThis command allows theThis command can then expediteDCB's in-transaction flag as we are going down. Subsequently a recommendation is given to the user followed by a prompt to continue. Once the user decides to proceed, the image will be downloaded to the controller. However, a reboot is required for the new image to take effect. Before you update the firmware,With it the warning message is suppressed, as Compatibility checks are not bypassed. If the These events are kept in a finite queue inside. These events reflect messages of varying severity levels. The levels range The default Likewise, the older the event The order of the messages could be With this the most recent AEN message Note that some characters might not be printable or rendered correctly (humanIt reports a list of phys with related information The 'Device Type' column indicates whether There are three 'Link Speed' The current link speed for phy1 is 3.0 Gpbs, and the link control setting isMoreover, the only changeableTo change the link speed, see the. To see information for an individualFor each activity, up to 7 tasks can be registered, Background tasks have Rebuilds can be started manually Scheduled rebuilds will take This command shows the current rebuild task rate of the The advanced Verify Task Schedule provides RAID-1 involves checking that both drives contain the exact data. On RAID-5 and. RAID-6, the parity information is used to verify data integrity. RAID-10 and 50 On the 9000 series, For the 9650SE and newer controllers, if the basic Verify Task Schedule is This command shows the current verify task rate of the For each activity, up to 7 tasks can be registered, known Background tasks have attributes of The SMART selftest instructs the controller to check certain SMART supported thresholdsThis command will fail if no (empty) slot is available. In that case,In that case, Simply specify a weekly day and time and make sure For more information. Features section of this document. This command will fail if no (empty) slot Otherwise, no firmware initiated or manually started rebuild tasks would run. Otherwise, no firmware initiated or manually started verify tasks would run. When enabled, only registered or scheduled tasks Setting this value to Conversely setting this value to 1 implies The Adaptive The Low Latency setting has been described above. Accordingly, the converse is also true. When enabled, only registered or scheduled Setting this value to 5 Conversely setting this value to 1 implies For more information, see the command Release 9.5.2 or later. Setting verify to advanced enables the Verify Tasks Schedule, which Setting verify toFor more information, see This command allows you to offset this condition by setting the rebuild mode to low The Adaptive The Low Latency setting has been described above. When enabled, the selftest task will beIf the policyFor example, given a spin up policy of 2, the controller will spin up two disksThe amount of timeThese statistics can be helpful when When the Auto-Carving policy is ON, any unit larger than the carvesize This feature is useful for For a 5 TB array, two 2 TB volumes This feature worksAfter the drives are inserted or re-inserted to Please note that the command takes longer to complete for ports that do not have This command applies to This command applies to If the Auto-Carving policy Verifying, Initializing, or Migrating). As a result, an added For example: The process of either. Verifing, Initializing, or Migrating is at 70 and it is a paused process. Currently, The unit is also in the paused An invalid attribute will terminate the loop. Possible attributes are: initializestatus, name (9000 series), qpolicy (9550SX If the queue Some drives For example, when a spare becomes a true unit in migration, it would adopt. Thus, this commmand does not show the If set to ON, the LEDs of the drive slots associated with the specified unit wouldThe state of the read cache could be either basic, intelligent, or. For more informationThis policy can be all, rebuild, or disable. For more information Exporting a unit will instructAs such the unit can later be importedDefault is to inform the OS. The quiet option is for non-interactive mode. Units that are currently in use or mountedDeleting a unit not only remove the Ports (or disks) associated with this In another words, onceDefault is to inform This is a destructive command and should be Units that are currently in use or mountedDuring rebuild, bad sectors on the source disk will cause the rebuild to fail. You can allow for the operation to continue via ignoreECC. Rebuild process isThis feature is intended for model 7000 and 8000Model 9000 has an on-board scheduler where rebuild operations can be scheduled If the allocated schedule windows isThis featureFor earlier controller models, This improves read access times for applications such as a database that Read cache may be disabled without This new feature includes a typical read ahead caching method, which is used For example, the By loading a larger set of data This can be helpful with applications that are Performance benefits of read-ahead In addition, Cache setting. If set to ON, Setting overwriteECC to on means ignoreECC. This feature only applies toNo space is allowed within the string. If user likes to use some special characters It is user's responsibility to give unique This feature only applies to 9000 models. If the queue policy isSome drivesFor example, when a Rapid RAID Recovery can speed up the rebuild process, and it can speed up This feature allows for Setting this The following description about the settingsWhen user sets storsave to protect, it means: When user sets the storsave BBU is installed and enabled; Otherwise, will be flushed to disk only, and For example, a valid number The destination unit must use all source. Unspecified parameters are assigned default values (stripe size of 64K, write If the source unit is of type. RAID-1 and the destination unit is of type single, the disk-specifier of the In this case, A four-drive RAID-5 unit can migrate to a four-drive. RAID-0, but a four-drive RAID-0 unit cannot migrate to a four-drive RAID-5, withoutOne or more ports. For exampleRecall that a RAID-50 is a multi-tier RAID-5 layer. These RAID-5 arrays are then integrated into a RAID-0. This option Valid values are 3, The following table By default CLI will inform the OS. One application By default the cache is enabled. Unless there is a BBU or UPS installed, to You can continueOnce the migration is finished, a reboot For secondary storage, depending For instructions, Making any physical changes to the Following those areAfter which example outputs showing theIn this example, In addition, the status of the newly specified disk Single to a RAID-1, initiated by the following commands: Western Digital disk with status OK and is a part of unit u5. This is a list of the possible One or many attributes can be requested. Invalid Possible attributes are: status, model,Its intended use is not for determining theNote the difference The LED of the drive slot associated with the specified port would blink if the The capacity in GB is computed basedTherefore, a requestThe 'type' in the command specifies which The options are either: inst for. Instantaneous, ra for Running Average, lct for Long Command Times,More detailed information regarding these statistics and the Drive. Performance Monitor is available in the Features section under 'Drive. Performance Monitor'. You can import (or re-introduce) the portUse noscan to bypass informing the OS of this The quiet option is for the non-interactive Drives, which are part of a redundantNon-redundant drives, If set to ON, the LED of the drive slot associated with the specified port would The optional 'type' in the command specifies which set of statistics data would be Command Times,and ext for Extended Drive Statistics. More detailed information If no type isMonitor' in the 'Features' section. This command presents a summary report on the The 'Device' column There are three 'Link Speed' columns: 'Supported' Note that the Supported and Enabled values are not changeable. The Control The default This command sets the link speed The unit of link speed is in gigabits per second (Gbps). The default is auto. The commands in this Both voltage and temperature BBU board. One or many attributes can be requested. Invalid attribute willPossible values are: It may take up to 24 hours to complete. During the test, the BBU is not capable of backup operation and the writeIf the test is completed withIf a Fault, Failed or an Error occurs during the test, the write cache remains at theThe charging is started automatically During the charging, the BBU is not capable Once charging is completedAt this state, the BBU is not capable of backup We recommend you to replace theAt this state, the BBU is not capable of backupWe recommend you to replace theAt this state, the BBU is not capable of backupWe recommend you to replace theThe status can be OK. HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are in warning range. TOO-HIGHThe status can be. OK, HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are in warning range. TOO-HIGH and TOO-LOW are out of the operating range and need to be concerned. The test may take up to 24 hoursThe performance of all units under theOnce the test Event Notifications) about the status of the test operation. The controller will utilize BBU The controller ignores the In another words, despiteThe enclosure element object messages are The subsectionsFor systems with the 9650SE controller or CCU enclosure, simply drop the pre-pended One or many An invalid attribute will terminate the loop. Possible For the new syntax, this command is not very useful, since the controller that the This command Status column lists the status of each slot, the (V)Port column shows the Status column lists the status of each fan, the State column shows if the fan If the image is valid a subsequent message will indicate It identifies the target SEP expander in the With it the warning message, version check, and The image will initiate the download immediately. Only expander models in this list are supported. Please refer to. Click on the Data and Interoperability tab, and then click on the 3ware. Interoperability Information link to check if your expander is supported.