kangaroo control enteral feeding pump manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:kangaroo control enteral feeding pump manual.pdf
Size: 4595 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 30 May 2019, 22:25 PM
Rating: 4.6/5 from 629 votes.
Status: AVAILABLE
Last checked: 15 Minutes ago!
In order to read or download kangaroo control enteral feeding pump manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
kangaroo control enteral feeding pump manualWith proper care, this device will provide you with years of precision service. TABLE OF CONTENTS Page Section I — General Information.5 Section II —. KANGAROO ePump features, front and rear views.See Section XIII - Service Part Numbers for replacement of Power Cord. 5. Use only KANGAROO ePump enteral feeding pump Pump Sets with this device. Pump is not compatible with other Pump Sets. See icon descriptions in Section III-Icon Identification and Section X - Specifications and Symbols for additional safety information. 12. This device is designed to minimize the effects of uncontrolled electromagnetic interference and other types of interference from external sources. Information Indicator This indicates information only, and does not require any immediate action.The pump can also be primed in a more interactive method using the hold- to-prime feature. If auto-priming is desired, press and release4AUTO PRIME to automatically prime the line(s). The continuous feeding mode will deliver the enteral nutrition at a steady rate, either until the programmed volume has been delivered or until the supply has been exhausted. Select this option to program the feeding parameters from the ADJUST BOLUS screen, Figure 12A. ADJUST BOLUS menu. Figure 12B. Setting the Bolus Rate. Figure 12C. Setting the Number of Boluses. Figure 12D. Setting the volume per Figure 12E. Setting the time interval Bolus.MORE OPTIONS screen, Figure 16. MORE OPTIONS Figure 16. MORE OPTIONS menu. OPTIONS menu. Accessing the BioTech Screen To get the BioTech screen, press the power button to start the pump, and press and hold the top4button while the startup sequence (Kangaroo icon “hops”. While the LOCK SETTINGS feature prevents only changes to the input parameters, the LOCK SCREEN feature will lock out any button presses, including RUN or HOLD, except power off. After cleaning, do not connect to AC power source until pump and power cord are thoroughly dry. Re-tighten Battery Door screw.http://www.techbis.pl/files/knights-wooden-castle-manual.xml
- Tags:
- kangaroo control enteral feeding pump manual, kangaroo control enteral feeding pump manual parts, kangaroo control enteral feeding pump manual pdf, kangaroo control enteral feeding pump manual transmission, kangaroo control enteral feeding pump manual diagram.
Could not find Stop Cock Feed Position during prime routine. Motor Error during Tubing AutoLoad. See Figure 24. The ROTOR ERROR generally results from a problem with the Pump Set tubing around the rotor. There is approximately 15 minutes of battery life remaining when this screen appears. Plug the power cord in to begin recharging. The pump will automatically return to the screen that was active prior to the error. All service personnel must be properly trained and qualified with operation of the KANGAROO ePump enteral feeding pump. Improper service may impair operation of the pump. The user of the pump should assure that it is used in such an environment. The reason for the accuracy of the KANGAROO ePump enteral feeding pump is the design, controlled calibration methods, and stringent manufacturing controls. Contact Us to Register Your Interest Already a member. Tyco grants the user a non-exclusive, limited license to use the software according to the operating instructions. A copy of the license can be obtained from Tyco. KANGAROO JOEY Enteral Feeding Pump features, front and rear views. KANGAROO JOEY Enteral Feeding Pump set loading area. Section II — Safety and Warnings CAUTION: U.S. federal law restricts the sale of this device to physicians or to their direct representatives. 1. Read this booklet thoroughly before using the KANGAROO JOEY Enteral Feeding Pump. 2. Do not use this device near flammable anesthetics. 3. Disconnect power supply before cleaning or servicing. 4. The KANGAROO JOEY Enteral Feeding pump utilizes a two prong, medical grade power supply cord specifically designed for use only with the KANGAROO JOEY feeding pump’s Lithium Ion battery charging circuit. Use of an alternate consumer style power cord or DC car adapter may cause damage to the charging circuit and battery of the KANGAROO JOEY feeding pump. Use only the supplied power adapter to charge your KANGAROO JOEY feeding pump from an AC power source.http://danielstrehlau.com/userfiles/knights-of-the-old-republic-manual.xml See Section XIII - Service Part Numbers for replacement of power cord. 5. Use only KANGAROO ePump Enteral Feeding Pump sets with this device. Pump is not compatible with other pump sets. 6. For re-certification, see Section VI - Re-certification of Performance. For other integrity checks, consult with a qualified Biomedical Technician or contact the manufacturer (Section XI - Customer Service). 7. For service or for technical information, please contact Customer Service (Section XI). 8. Do not open the main housing, as there are no user-serviceable parts inside. Opening may affect function of device and voids the warranty. To replace battery, see Section VIII. 9. Dispose of old battery-powered electronic equipment in a manner consistent with institutional policy for expired equipment disposal. 10. Cleaning frequency and practices must be consistent with institutional policy for cleaning of non-sterile devices. See Section VII - Cleaning, for instructions on cleaning the KANGAROO JOEY Enteral Feeding Pump. 11. See icon descriptions in Section III - Icon Identification and Section X - Specifications and Symbols for additional safety information. 12. This device is designed to minimize the effects of uncontrolled electromagnetic interference and other types of interference from external sources. Premature infants may require higher accuracy rates than specified for this enteral feeding pump. For optimal accuracy, the top of the starting volume of formula should be 6 inches above the pump, do not reuse feeding sets and avoid overstretching the silicone that wraps around the pump rotor. 15. Do not attempt to rotate the valve stem inside the feeding set valve assembly. Rotation of the valve stem can only be done by the pump while the valve assembly is properly loaded into the pump. 16. Should feeding sets require rinsing, it is recommended that the feeding sets be rinsed while they are loaded in the pump. 17.https://events.citeve.pt/chat-conversation/boss-loop-station-rc2-manual The KANGAROO JOEY Enteral Feeding Pump has been programmed to optimize accuracy by taking into account the viscosity of formula. Formula that has been diluted and has a low viscosity will tend to deliver like water and thus deliver to the high side of the accuracy specification. 18. CAUTION: Ensure buzzer hole is unobstructed during normal operation so as to allow clear recognition of alarm. 19. CAUTION: The battery cells used in this device may present a fire or chemical hazard if mistreated. Volume Setting Indicates alarm volume setting. Error Indicator Pump operations are stopped until the error is resolved. EZ Pump Mode Indicator Indicates that EZ Pump Mode feature is activated. Communication Indicator Indicates that communication feature is activated. Volume to be Delivered Indicator Indicates that a VTBD has been programmed. Keep Tube Open Indicates that Keep Tube Open feature is in operation. See Figure 1A to locate port on pump. NOTE: It is important to make sure the power plug is pushed all the way into the pump for proper operation. Battery Setup The battery is packed partially charged. It is also recommended that the battery charge be “topped off” before battery-only operation is utilized. A new battery pack will provide approximately 18 hours of service before needing to be recharged. The pole clamp provides the ability to retain the power cord to prevent accidental cord removal or cord loss. Simply wrap the cord around the cord wrap posts to ensure that the cord stays with the pump. To attach the pole clamp to the pump, simply slide the clamp onto the mounting stud on the back of the pump (Figure 3A). When engaged, turn the lever to secure attachment. Attaching and using the Pole Clamps. Pull up on retainer and insert into back pocket (3). The continuous or intermittent feed mode selection is made under the MORE options menu. 8. Press4RUN when ready to start. The screen will display RUNNING. 9.https://laurenmitchellband.com/images/990cxi-service-manual.pdf To stop, press4HOLD or press and hold the Black Ring Retainer (MISTIC) 3 POWER button. Rotor 2 1 182541 Finger Tab 6 in (15.2 cm) Valve Figure 4A. Installation of Pump Set. (See Figure 6 for detailed view.) WARNING: DO NOT OVERSTRETCH TUBE. Figure 4B. Correct Fluid Level. The built-in battery recharges any time the pump is plugged into an outlet. Contact Customer Service, Section XI, to replace the battery pack if battery life degrades. Note: The KANGAROO JOEY Enteral Feeding Pump will not operate unless an approved KANGAROO JOEY Enteral Feeding Pump battery pack is installed in the pump. To power down the pump, press and hold the POWER button until the pump display turns off. Language Selection, First Power Up Immediately after powering up the pump for the first time, the language option screen will appear. Select the language using the ( ? ) or ( ? ) buttons. When the language is selected, push the fifth button ( ? ) to enter the language selection. After the language is selected the first time the pump is powered up, the language selection screen will not appear during future power up operations. Should the language need to be changed after the initial power up, it can be changed through the “MORE OPTIONS” menu (see Figure 10A). Keep or Clear Prior Pump Settings Immediately after powering up the pump, if the prior feed or flush settings were not cleared and the settings are not locked in the BioTech Screen, the pump will give the following two options: KEEP SETTINGS - Select this option to start with the same settings that were most recently programmed into the pump. Any of the previously-programmed settings can be modified, if needed. The feed volume totals, “mL FED” (Continuous Feed Mode) or “BOLUSES FED” (Intermittent Feed Mode) and “mL FLUSH” are also maintained. If VTBD has been set, the VTBD setting originally programmed will not change, however value to be delivered will restart at one. CLEAR SETTINGS - Select this option to reset all input feeding settings and the output feed totals to zero. It will then be necessary to program all settings before running the pump. The BioTech options settings will not change. A blinking icon of a pump set will also appear in the upper left corner of the screen. Figure 5A shows the screen for continuous feeding mode and Figure 5B shows the screen for intermittent feeding mode (intermittent feeding mode not available in EZ Pump Mode). Figure 5A. LOAD A SET opening menu screen for Continuous Feeding mode (EZ Pump Mode not activated). Figure 5B. LOAD A SET opening menu screen for Intermittent Feeding mode (EZ Pump Mode not activated). To load a Pump Set, follow the steps below: 1. With the pump display facing you, open the blue transparent door that encloses the rotor and pump set loading area. 2. Load the pump set by holding the finger tab on the valve, then inserting the valve into the valve slot on the left. (Figure 6A) 3. Grasp the MISTIC retainer end (black ring retainer) and wrap the tubing counterclockwise around the rotor. Avoid overstretching the silicone tubing. (Figure 6B). 4. Carefully pull the MISTIC retainer end left and upwards to position it over the slot on the left, and then lower the retainer into the slot. Push down on the retainer then release to ensure proper engagement. (Figure 6B) 5. Push the valve’s finger tab to the right to ensure proper seating. 6. Close the blue transparent door, checking to make sure the valve finger tab is captured by the slot in the blue door. The pump can also be primed in a more interactive method using the hold-to-prime feature. Auto Priming The AUTO PRIME option will be available if the pump senses that the currently installed pump set was not previously primed, and that there is no fluid in the line near the rotor. If auto-priming is desired, press and release4AUTO PRIME to automatically prime the line(s). Press4STOP to cancel AUTO PRIME. Be sure that the line(s) are fully primed. If not, use the hold-to-prime option(s) to complete the priming, as described below. Hold-to-Prime The hold-to-prime options allow for precise interactive control of the priming process. Feed-Only Pump Sets For Feed-Only Pump Sets, the screen will appear as in Figure 8A. Press and hold4HOLD TO PRIME FEED until the feed line has been primed down to the stepped end connector at the end of the pump set. First press and hold4HOLD TO PRIME FLUSH to prime the flushing line, and then press and hold4HOLD TO PRIME FEED to prime the feed line down to the stepped end connector at the end of the pump set. If the feeding line is primed first, subsequent priming of the flushing line will force the air between the flush solution bag and valve into the main line, which already has been primed with enteral formula. Re-priming after Bag Empty A pump set bag that has been emptied will trigger the FEED ERROR screen. In this condition the pump set bag can be refilled to continue the feeding, but only after the pump set has been re-primed. Selecting Feed Mode EZ Pump Mode Option The EZ Pump Mode option is a limited, Continuous Mode only setting of KANGAROO JOEY Enteral Feeding Pump. It has no Bolus, Flushing, Run Mode Screen Lock, or AutoResume capability and displays no History information. Although the Continuous Mode feed VTBD will be set to 0 while EZ Pump Mode is enabled, the previous value of the Feed VTBD will be stored in the pump memory and recalled when “EZ Pump Mode” is deselected. The user can change the Feed Rate by normal means. All other user settings, including those not compatible with the EZ Pump Mode (Bolus VTBD, Number of Boluses, Super Bolus, etc), that were set before the pump was put into the EZ Pump Mode will be ignored and invisible while in EZ Pump Mode but remain stored in the pump memory for when EZ Pump Mode is deselected. EZ Pump Mode essentially has no effect on Clear Settings; pressing Clear Settings while EZ Pump Mode is enabled will clear all Feed and Flush settings and totalizers as normal, not just those that apply to EZ Pump Mode. Selecting the Clear Settings option on power up will not clear Biotech Options such as EZ Pump Mode or Lock Settings. If the user selects the Adjust Feed option from either the Load A Set or Set Loaded screens, control will pass directly to and from the Enter Feed Rate screen and bypass the Adjust Feed screen since without the ability to adjust VTBD in EZ Pump Mode, the Adjust Feed screen is redundant. Selecting EZ Pump Mode EZ Pump Mode may be selected through the Biotech Options button which may be accessed on the Biotech screen (see page 22). The EZ Pump Mode setting will be stored in the machine pump memory and saved when the unit is shut off. If EZ Pump Mode is desired, the user must then re-enable EZ Pump Mode through the Biotech Options screen. When enabled and not in Certification mode, a small EZ icon will be visible on the bottom of the screen near the battery icon. However, it will not appear in the Power Down, System Error, or Low Battery screens. Figure 9. Selecting Continuous or Intermittent Feed Mode The KANGAROO JOEY Enteral Feeding Pump can be programmed to feed continuously or intermittently. The continuous feeding mode will deliver the enteral nutrition at a steady rate, either until the programmed volume has been delivered or until the supply has been exhausted. The Intermittent feeding mode delivers boluses of enteral nutrition at programmed time intervals. The bolus volume and feed rate are also programmed. To select continuous feed mode or intermittent feed mode, press4MORE on the opening menu, shown in Figures 5A-5B or Figures 7A-7D, to access the MORE OPTIONS menu, Figure 10A. The MORE option is available either before a pump set has been loaded (Figures 5A-5B) or after the pump set is loaded (Figures 7A7D). See subsection “More Options” for information on the other options in the MORE OPTIONS menu. Then press 4CONTINUOUS MODE or4INTERMITTENT MODE from the SELECT MODE menu, Figure 10B. Press4DONE to exit. Figure 10A. MORE OPTIONS menu. Figure 10B. SELECT MODE menu for continuous or intermittent mode selection. Select this option to program the feeding parameters from the ADJUST FEED screen, Figure 11A. Press4FEED RATE in Figure 11A to define the rate of delivery. Press4ENTER (top button) to exit the menu. Press4FEED VTBD in Figure 11A to define the Volume To Be Delivered. Press the4buttons in Figure 11C to program the volume from 1 to 3000 mL in increments of 1 mL. If the FEED VTBD is set to zero, the pump will run until the supply is exhausted. NOTE: When a FEED VTBD is set, the remaining volume to be delivered (remaining VTBD) will be displayed next to the W icon on the lower right-hand portion of the screen (Figure 11A). If the FEED VTBD is reprogrammed during a feeding, from HOLDING mode, the pump will restart the feeding and deliver the entire volume of the new VTBD setting. Figure 11A. ADJUST FEED menu. Figure 11B. Setting the Feed Rate. Figure 11C. Setting the Feed Volume to be Delivered. Press4ADJUST FLUSH in Figure 7B to program the flushing parameters from the ADJUST FLUSH screen, shown in Figure 12A. Press4FLUSH VOLUME in Figure 12A to define the volume per flush occurrence. Press the4buttons in Figure 12B to program the flush volume from 10 to 500 in increments of 1 mL. Press the4buttons in Figure 12C to program the time interval from 1 to 24 hours in increments of 1 hour. The pump will automatically limit flushing settings which exceed pump capabilities to deliver. NOTE: The pump will automatically flush an additional 25 mL of water after completing the programmed delivery of formula, as long as at least one flush had occurred during formula delivery. Figure 12A. ADJUST FLUSH menu, continuous mode. Figure 12B. Setting the Flush Volume. Figure 12C. Setting the Flush Time Interval. Select this option to program the feeding parameters from the ADJUST BOLUS screen, Figure 13A. Press4BOLUS RATE in Figure 13A to define the rate of delivery. Press4NUMBER OF BOLUSES in Figure 13A to define the total number of boluses to be delivered. Press the4 buttons in Figure 13C to program the number of boluses, up to a maximum of 99. The number of boluses can be set as zero, in which case the pump will run until the supply is exhausted. Press4VOLUME PER BOLUS in Figure 13A to define the Volume to be delivered in each bolus. Press the4buttons in Figure 13D to program the volume per bolus from 1 to 3000 mL in increments of 1 mL. Press4BOLUS INTERVAL in Figure 13A to define the time interval between starts of bolus deliveries. Press the4buttons in Figure 13E to program the time interval between starts of bolus deliveries from 1 to 24 hours in increments of 1 hour. The pump will automatically limit bolus settings which exceed pump delivery capabilities. In this case, the maximum volume allowed would be 150 mL. Press4BOLUS MAX in the BOLUS RATE menu, Figure 13B, to program the BOLUS MAX mode. Press4ADJUST FLUSH in Figure 7D to program the flushing parameters from the ADJUST FLUSH screen, Figure 14A. ADJUST FLUSH menu, intermittent mode. Figure 14B. Setting the Flush Volume. Figure 14C. Setting the Flush Time Interval. Note: The nature of two intermittent processes, periodic bolus feeding and periodic flushing, is such that occasional conflicts can arise where each process needs to be running at the same time. It also means that a flush cycle will interrupt a bolus feeding cycle that is already in progress. The feeding cycle will pick up where it was interrupted after the flushing cycle is complete. It is therefore possible that the net feeding volume is reduced from what may be intended, over a given time period. Press4FLUSH VOLUME in Figure 14A to define the volume per flush cycle. Press the4buttons in Figure 14B to program the flush volume from 10 to 500 in increments of 1 mL. Press4FLUSH INTERVAL in Figure 14A to define the time interval between starts of flushing. Press the4buttons in Figure 14C to program the time interval from 1 to 24 hours in increments of 1 hour. Press4ENTER to exit the menu. NOTE: The pump will automatically flush an additional 25 mL of water after completing the programmed delivery of formula, as long as at least one flush had occurred during formula delivery. Run The KANGAROO JOEY Enteral Feeding Pump will only run when a pump set is properly loaded and the necessary feeding parameters have been programmed. If flushing parameters are set as zeros, there will be no flushing. After the pump has been programmed, press4RUN to start operation. Figure 15A shows the RUNNING screen for continuous feeding with flushing. The status line will indicate RUNNING, and the droplet icon will move vertically on the screen. The green LED indicator will be illuminated to give a quick visual indication of positive status in a darkened room. The remaining VTBD is shown next to the W icon. RUNNING mode screen for continuous feed mode. Figure 15B. KTO. Figure 16. Program Locked screen, which indicates the pump is in LOCK SETTINGS mode. KTO (Not Available in EZ Pump Mode) The Keep Tube Open (KTO) function within the KANGAROO JOEY Enteral Feeding Pump will help prevent a blockage of the feeding set by moving the feeding solution periodically within the tube. On regular intervals, calculated from the pump’s presently programmed feed rate, a small and clinically insignificant portion of feeding solution is moved through the tube. The amount of delivered fluid is monitored, tracked, and calculated into the final feed volume totalizer amounts displayed to the user. The KTO feature can be activated via the RUNNING screen. To activate the KTO feature, press the input button to the left of the KTO icon, see Figure 15A, to immediately input a desired time in minutes for which the pump will remain in the “Keep Tube Open” mode before resuming the previously programmed feeding regimen. Each press of the input button will increment the KTO time by 5-minute increments, up to 30 minutes, see Figure 15B. After “30” is reached, each additional button press will increment in larger time steps, up to a maximum of 240 minutes. Another button push after 240 will cycle the KTO back to 5 minutes. No other input is needed to start the countdown, as the time immediately counts down after the incremental value is reached. Lock Screen Feature The KANGAROO JOEY Enteral Feeding Pump can be set to RUN and then be locked out from unintended use. While the LOCK SETTINGS feature prevents changes only to the input parameters, the LOCK SCREEN feature will lock out any button presses, including RUN or HOLD, except power off. Use LOCK SCREEN when the pump is running and there is a need to prevent unintended button activation, such as putting the pump into an unwanted HOLD. The RUNNING screen will show a padlock to indicate that no changes can be made without unlocking the screen. To unlock the screen, use the same procedure above. Figure 17. Padlock indicates pump is in LOCK SCREEN mode. The status line will indicate HOLDING and the yellow LED indicator will be lit up to give a quick visual indication of an informational status in a darkened room. Note: the pump’s alarm will sound if it has been left HOLDING for 10 minutes without further input. There are five options available during HOLDING. See Figures 18A and 18B. Figure 18A. HOLDING mode options, continuous feeding mode. Figure 18B. HOLDING mode options, intermittent feeding mode. Clear Volume Fed Press4CLEAR VOLUME to re-zero the output feed totals “mL FED,” “BOLUSES FED,” and “mL FLUSH.” Adjust Settings Press4ADJUST SETTINGS to return to one of the opening menus shown in Figures 7A-7D, thus allowing any setting to be modified. If the pump set has been removed after going into HOLD, the opening menu will show LOAD A SET, as seen in Figures 5A-5B. No other input is needed to start the countdown, as the time immediately counts down after the 30-minute value is reached. Run Press4RUN to immediately restart pump operation. This option will not be available if the pump set is removed during HOLD. History (Not Available in EZ Pump Mode) Press4HISTORY to access the HISTORY screen. Use this screen to review feeding and flushing history. See subsection “More Options” below for further information. See Figure 15A. When4FLUSH NOW is pressed, the screen will prompt for the volume to be immediately flushed, and will show the previously programmed flush volume as default but may be adjusted to the users desired volume. The screen will appear as the standard Flush input screen as shown in Figure 12B (or 14B). If4FLUSH NOW is pressed by accident; the user may either press the cancel button or allow the screen to return to the RUNNING screen after 10 seconds, if there is no input for the flush volume. If stopping a FLUSH NOW before the set volume has been delivered is desired, press4FLUSH NOW and enter a volume of zero and press4ENTER. The FLUSH NOW will stop immediately and the pump will return to the RUNNING mode. More Options Press4MORE in one of the opening menus, Figures 5A-5B or Figures 7A-7D, to access the MORE OPTIONS screen, Figure 19. Figure 19. MORE OPTIONS menu. Buzzer Press4BUZZER in the MORE OPTIONS menu to access the BUZZER screen and increase or decrease the alarm buzzer volume. The alarm will be audible as the volume setting is changed. This sets the volume level for any warning or error that may occur with the pump. Critical errors of System Error and Pump Set Dislodged will always use the maximum volume setting. History (Not Available in EZ Pump Mode) Press4HISTORY in the MORE OPTIONS menu to access the HISTORY screen. Press the4buttons in Figure 20 to set the time history of interest. The totals of FEED mL and FLUSH mL will be shown for the requested history time. WARNING: A maximum of 72 hours of past history can be retrieved, excluding data from the current hour. NOTE: The 72-hour history includes time when the pump is powered OFF. Feed and Flush totals for up to 72 hours of previous history, excluding data from the current hour. Languages Press4LANGUAGES in the MORE OPTIONS menu to change the preferred language for the screen interface. Use this menu to select between continuous feeding mode and intermittent feeding mode. See subsection “Selecting Continuous or Intermittent Feed Mode” for more information. Press4DONE in the MORE OPTIONS menu to exit the menu. BioTech Menu The BioTech screen will show technical information about the pump, and has a lock feature to lock the Pump Settings against unauthorized changes. Accessing the BioTech Screen To get the BioTech screen, press the power button to start the pump, and press and hold the top4button while the startup sequence (kangaroo icon “hops” across the screen) executes. You must be pressing the top4button at the end of the sequence in order to access the BioTech menu. Figure 21 shows the BioTech screen. Figure 21. BioTech screen. BioTech Screen Data SN is the serial number of the pump. SW shows the software version number in this pump. FLASH shows the version number of the flash data installed in this pump. Submit a request and we'll email you a quote! Please provide some content! It is essential for Quite often, the issue can This increasing demand has led to Retains flow rate, dose and volume delivered in memory for 24 hours after pump shut-off. Sign in Forgot Password. My Bench Close Sign In Not A Member. Sign Up Join MedWrench OK name type Receive Summary Emails. The easy-to-use controls make set-up and operation of the unit intuitive. The Kangaroo and trade 924 pump is used exclusively with the Kangaroo and trade 924 pump sets. FORUMS View All (4) Ask a New Question 1 Reply -MHud a year ago a year ago user maual user manualI have cleared the error and the pump runs fine for a short time, then it begins beeping again.The battery will charge when the AC Adapter is plugged into an outlet. Total time to charge the 924 pump is approximately 8 hours. Battery life is determined based on 125mls per hour feed rate. This allows for simplified use and minimizes potential for errors in provider programming. When powered on, the pump automatically reverts back to previous settings within this time range. The added visual alarm provides for a greater sense of patient safety, especially in Home Care markets. Indicates for AC connectivity and Vol Clear. The built-in pump handle also provides for greater flexibility and easy movement. This unique feature provides for safeguards against improper placement and results in increased patient safety. By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details. All Rights Reserved. Having a medical device that takes the stress out ofOne excellent option is the Kangaroo Pump, made by Cardinal. Health (formerly Covidien), which is well suited for home use and is often theSetup and Preparation 2.Connect Battery Pack 3. Attach Pole Clamp 4. Press the Power. Button on the Control Pad 5. Keep or Clear. Settings 6. Open Pump Set Loading. Area 7. Load Pump Set 8. Prime Pump 9. Set Feeding Mode and. Parameters 10. Press Run Below is a quick-reference user guide to get you started. The instructions for operating your Kangaroo Pump are straightforward andKangaroo Feeding Pump Operating Manual. 1.