ibm storage configuration manager manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:ibm storage configuration manager manual.pdf
Size: 2873 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 30 May 2019, 21:21 PM
Rating: 4.6/5 from 569 votes.
Status: AVAILABLE
Last checked: 12 Minutes ago!
In order to read or download ibm storage configuration manager manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
ibm storage configuration manager manualSearch support or find a product: Search Our apologies No results were found for your search query. Tips To return expected results, you can: Reduce the number of search terms. Each term you use focuses the search further. Check your spelling. A single misspelled or incorrectly typed term can change your result. If so, follow the appropriate link below to find the content you need. Our apologies Search results are not available at this time. Please try again later or use one of the other support options on this page. No results were found for your search query. Tips To return expected results, you can: Reduce the number of search terms. Each term you use focuses the search further. Check your spelling. A single misspelled or incorrectly typed term can change your result. If so, follow the appropriate link below to find the content you need. Managed devices include theConnectivity Module for IBM BladeCenter products in a BladeCenterStorage Configuration Manager runs as a Web server thatYou can connect to IBM. Storage Configuration Manager from any host on the network usingSystems. ToolsCenter licenses ToolsCenter page. Search support or find a product: Search Our apologies No results were found for your search query. Tips To return expected results, you can: Reduce the number of search terms. Each term you use focuses the search further. Check your spelling. A single misspelled or incorrectly typed term can change your result. If so, follow the appropriate link below to find the content you need. Our apologies Search results are not available at this time. Please try again later or use one of the other support options on this page. No results were found for your search query. Tips To return expected results, you can: Reduce the number of search terms. Each term you use focuses the search further. Check your spelling. A single misspelled or incorrectly typed term can change your result. If so, follow the appropriate link below to find the content you need.http://cornwallstaffagency.com/userfiles/dx4600-pelco-manual.xml
- Tags:
- ibm storage configuration manager manual, ibm storage configuration manager manual pdf, ibm storage configuration manager manual download, ibm storage configuration manager manual software, ibm storage configuration manager manual user.
Disable Linux slpd before installing SCM. Search support or find a product: Search Our apologies No results were found for your search query. Tips To return expected results, you can: Reduce the number of search terms. Each term you use focuses the search further. Check your spelling. A single misspelled or incorrectly typed term can change your result. If so, follow the appropriate link below to find the content you need. Our apologies Search results are not available at this time. Please try again later or use one of the other support options on this page. No results were found for your search query. Tips To return expected results, you can: Reduce the number of search terms. Each term you use focuses the search further. Check your spelling. A single misspelled or incorrectly typed term can change your result. If so, follow the appropriate link below to find the content you need. Attaching an external tape d. Troubleshooting Getting help and technical ass. It also provides system health The second However, you can change the password The following TheIBM Storage Configuration Manager service starts. IBM BladeCenter S SAS RAID Controller Module Installation And User Manual: Installing Ibm Storage Configuration Manager; User Id And Password 8886: IBM Storage Configuration Manager for Windows and Linux on x86: IBM Storage Configuration Manager for Windows and Linux on x86. The IBM Storage Configuration Manager is a systems management application used for managing and configuring SAS and storage devices. A single instance of Storage Configuration Manager can help you manage the devices in up to eight BladeCenter chassis at the same time. Therefore, you can The SMI-S provider for the IBM BladeCenter S SAS RAID Controller Module must be discovered Add the Storage System to the SMI-S provider configuration. 26 Apr 2010 Pc games software, Lenovo z560 onekey recovery, Ico format plugin photoshop, Shiva stuti mp3, Rumore folla itunes. Reload to refresh your session.http://audit-advisers.com/userfiles/dx4050-printer-manual.xml Reload to refresh your session. Installation and User s Guide Sixth Edition (February 2010) Copyright International Business Machines Corporation 2008, US Government Users Restricted Rights Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp. This guide contains instructions for the installation of the IBM BladeCenter S SAS RAID Controller Modules (SAS RAID Modules) into an IBM BladeCenter S chassis. This guide also contains information about the interfaces you can use to configure and maintain your SAS RAID Modules and other associated components you might be using. Data storage subsystems Two subsystems are involved in IBM BladeCenter S data storage: the Disk Storage Module (DSM), and SAS RAID Module. The Disk Storage Module (DSM) is an enclosure holding up to six Disk Drive Modules (DDMs). There are a maximum of two DSMs installed in an IBM BladeCenter S chassis. SAS RAID Module subsystems The SAS RAID Module includes two subsystems: a RAID Controller subsystem, and a SAS Switch subsystem. The SAS RAID Modules provide a connection between the Blade servers and the DSMs that allow you to design storage configurations and volumes for your data. In addition, a SAS Expansion Card must be installed in each blade server for the blades to connect to the RAID Data Storage subsystem and modules. Firmware updates The DDM, DSM, RAID Controller, and SAS Switch require firmware updates. Two methods of updating the firmware are as follows: v IBM Storage Configuration Manager (SCM) The IBM Storage Configuration Manager is a web-based system management application that you can use to update firmware on the IBM BladeCenter S SAS RAID Controller Module, DSM, and DDM, as well as manage and configure IBM BladeCenter devices.For installation and configuration instructions, refer to the IBM Storage Configuration Manager documentation.http://eco-region31.ru/bosch-pressure-washer-service-manual SAS RAID Controller Firmware Update Package The SAS RAID Controller Firmware Update Package is a CLI- based application package that you can use to update the IBM BladeCenter S SAS RAID Controller Module, DSM and DDM firmware. You can also write scripts automating firmware updates of single or multiple IBM BladeCenter S units. Note: Install the SAS RAID Controller Firmware Update Package on an Ethernet connected workstation or laptop running a Windows or Linux operating system. Copyright IBM Corp. 2008, Product description and package contents The IBM BladeCenter S SAS RAID Controller Module provides fully-integrated RAID Storage Area Network (SAN) functionality, inside your IBM BladeCenter S chassis. Each IBM BladeCenter S SAS RAID Controller Module ships with the following: v 43W3584 IBM BladeCenter S SAS RAID Controller Module Option v 46C8000 Publication Package v 46C8001 Quick Start Manual v 46C8002 Support CD v 46C8011 SCM CD v 46D0791 Flyer v 17P8568 L1 for Battery Backup Unit v 22R6649 Top Level Assembly Battery Backup Unit v 43W3604 L1 for IBM BladeCenter S SAS RAID Controller Module v 17P9375 Aristos EULA v 17P9277 Top Level Assembly IBM BladeCenter S SAS RAID Controller Module The IBM BladeCenter S SAS RAID Controller Module consists of an integrated SAS Switch combined with a RAID Controller which provides an embedded RAID storage solution with advanced SAN features to the IBM BladeCenter S chassis.http://dana1157.com/images/c50-owners-manual-pdf.pdf Your IBM BladeCenter S SAS RAID Controller Module features the IBM Storage Configuration Manager which provides end-to-end storage management: v Fast and easy set up with the Initial Setup wizard v System health monitoring v Storage configuration (creates pools, defines volumes, and maps to hosts) v v SAS RAID Module maintenance including firmware updates and device user management Troubleshooting Supported operating systems and drives The IBM BladeCenter Interoperability guide provides a listing of the interoperability between operating systems, drive types, and other components supported for use with the IBM BladeCenter S SAS RAID Controller Module. The following are also required: v v One or two IBM BladeCenter S SAS RAID Controller Modules. For example, if you are using the IBM Storage Configuration Manager application to configure your storage and data redundancies and maintain your firmware, the steps you take to accomplish this are more automated than if you are using the RAID Controller command line interface and, or the SAS RAID Controller Firmware Update Package to do these things. However, despite the manner in which you choose to accomplish your system storage configurations and maintenance, the IBM BladeCenter S SAS RAID Controller Module enables you configure your integrated storage solutions by performing the following: Chapter 1. Introduction 3 Important: Before you begin the process of storage configuration, use the RAID Controller command line interface to set up your to receive system alerts and log output. Documentation notes Table 2.http://www.getfitcrew.com/wp-content/plugins/formcraft/file-upload/server/content/files/1629b2a2fdd180---cost-accounting-a-managerial-emphasis-13th-edition-solutions-manual-free-download.pdf Important notes Summary Throughout this document, the user name is also known as the login name, user identifier, or user ID for logging into one or more of the following interfaces or programs: v Telnet interface v Web browser interface v Advanced management module Web interface v IBM Storage Configuration Manager Web interface Note: The IBM Storage Configuration Manager has two login screens: One to the server and the other to the RAID Controller.Requirement: To use an SAS RAID Module, a Battery Backup Unit must be installed in bay 1 of the media tray. If you have two SAS RAID Modules, install a second Battery Backup Unit in bay 2 of the media tray. You can obtain up-to-date information about the SAS RAID Modules and other IBM products at The controller module has the following labels: 1. Safety certification label 2. Product name label 3. Serial number label 4. Media access control (MAC) address label 5. SAS ID The major components topic contains an illustration that shows the location of the SAS RAID Modules labels. Note: This information is required when you register the SAS RAID Modules with IBM. Preinstallation safety information This topic contains important safety information. Read before installing this product. 4: IBM SAS RAID Controller Module. Lees voordat u dit product installeert eerst de veiligheidsvoorschriften. Vor der Installation dieses Produkts die Sicherheitshinweise lesen. Prima di installare questo prodotto, leggere le Informazioni sulla Sicurezza. Statement 1 DANGER Electrical current from power, telephone, and communication cables is hazardous. To avoid a shock hazard: v Do not connect or disconnect any cables or perform installation, maintenance, or reconfiguration of this product during an electrical storm.Statement 2 CAUTION: If your system has a module containing a lithium battery, replace it only with the same module type made by the same manufacturer. Batteries can explode if not properly used, handled, or disposed.fameyang.com/archive/upload/files/british-standard-manual-call-points.pdfStatement 21 CAUTION: Hazardous energy is present when the blade server is connected to the power source. Always replace the blade server cover before installing the blade server Handling static-sensitive devices Static electricity can damage electronic devices, including your blade server. To avoid damage, keep static-sensitive devices in their static-protective packages until you are ready to install them. To reduce the possibility of damage from electrostatic discharge, observe the following precautions: v v v v v v v v When you work on a IBM BladeCenter S chassis that has an electrostatic discharge (ESD) connector, use a wrist strap when you handle modules, optional devices, or blade servers. To work correctly, the wrist strap must have a good contact on both ends. It should touch your skin at one end and firmly connected to the ESD connector on the front or back of the IBM BladeCenter S chassis. Limit your movement. Movement can cause static electricity to build up around you. Handle the device carefully: holding it by its edges or its frame. Do not touch solder joints, pins, or exposed circuitry. Do not leave the device where others can handle and damage it. While the device is still in its static-protective package, touch it to any unpainted metal surface of the IBM BladeCenter S chassis or any unpainted metal surface on any other grounded component in the rack you are installing the device in for at least 2 seconds. (This drains static electricity from the package and from your body.) Remove the device from its package and install it directly into the blade server without setting down the device. If it is necessary to set down the device, place it back into its static-protective package. Do not place the device on your blade server cover or on a metal surface. Take additional care when handling devices during cold weather. Heating reduces indoor humidity and increases static electricity.http://www.norestim.ro/wp-content/plugins/formcraft/file-upload/server/content/files/1629b2a3f19c5f---Cost-accounting-a-managerial-emphasis-13th-edition-solutions-manual-free.pdf Hardware features and specifications This section provides a summary of the features and specifications for the IBM BladeCenter S SAS RAID Controller Module.The following are standard features of the IBM BladeCenter S chassis: v An Advanced Management Module v Two or more power modules v Four fan modules v A media tray You might receive additional features depending on what you ordered. Table 3. Features SAS RAID Module features SAS RAID Module maintainability SAS RAID Module electrical specifications: v SAS RAID Module and SAS expander v Vitesse 7157 v v Diagnostics: Power-on self-test (POST) is performed on all functional components. Port operational tests include internal, external, and online tests.Your hardware might have labels not shown in the following illustrations. Figure 1. Front view of an IBM BladeCenter S chassis Chapter 1. Introduction 9 Use logical identifiers to identify a specific resource for commands, status, and messages. Use physical location codes to identify a specific resource in the physical world; this helps identify the exact location of a resource when you remove or replace them. You can see logical identifiers and physical location codes in IBM Storage Configuration Manager by performing the following steps: 1. From the IBM Storage Configuration Manager navigation panel, select Health Physical View. The Physical View page displays a graphical representation of the devices on your server. 2. Hover the mouse cursor over the resources that appear in the Physical View page to display the logical identifiers and physical location codes. Option package contents This topic describes the contents of the option package. 10: IBM SAS RAID Controller Module The connectivity module option package contains the following items: v One IBM BladeCenter S SAS RAID Controller Module v One Battery Backup Unit (22R6833) is bundled with each IBM BladeCenter S SAS RAID Controller Module.http://2girlstrippin.com/wp-content/plugins/formcraft/file-upload/server/content/files/1629b2a4497d0c---cost-accounting-a-managerial-emphasis-13th-edition-solution-manual-pdf.pdfThese installation topics are provided in Portable Document Format (PDF) on the support CD that came with your RAID Controller. Additional related documentation might be included on the support CD or available on the IBM support Web site, along with the following related documentation: v IBM BladeCenter Installation and User s Guide contains setup and installation instructions for your IBM BladeCenter S chassis, including information about getting started and how to install a blade server.It also contains information about using the LSI Logic Configuration Utility program to configure the SAS Expansion Card.Each caution and danger statement has an assigned number, which you can use to locate the corresponding statement in your native language.It contains troubleshooting information for yourself or to provide to a service technician. Depending on your Blade Server model, additional documents might be included on the IBM BladeCenter Documentation CD, with the most recent versions of all BladeCenter documents available at Chapter 1. Introduction 11 For more information, see The IBM BladeCenter S chassis requires one Battery Backup Unit, part number 22R6833, for each SAS RAID Module to function. Understanding Battery Backup Units Battery Backup Units (BBUs) can provide enough reserve power to store data in your IBM BladeCenter S SAS RAID Controller Module memory cache for 72 hours in the event of an interruption of power. Battery Backup Units automatically recharge once they are inserted into the IBM BladeCenter S chassis. Note: Like all batteries, Battery Backup Units degrade over time. You should install Battery Backup Units within 90 days of the date of purchase so that they can begin recharging, and do not take them out of the IBM BladeCenter S chassis for extended periods of time. The first battery expiration notification is made 90 days before the expiration date listed. Subsequent notifications are made at 30 and 15 days.www.gulfstreamkelowna.com/files/british-standard-manual-alphabet.pdf You must replace the Battery Backup Units before the final expiration date occurs. If the Battery Backup Units expire, the RAID Controller enters into a cache write-through mode until you install new Battery Backup Units. This causes a significant delay in processing speed. IBM consumable parts Consumable parts (parts that are purchased separately) are not covered by the IBM Statement of Limited Warranty. Copyright IBM Corp. 2008, 22 Environmental considerations Follow the laws and guidelines for battery and other hazardous waste disposal in your area. Quick facts about Battery Backup Units Battery backup units provide backup for SAS RAID controller modules cache. Battery Backup Units are installed in the battery backup unit bays located in the media tray when you install SAS RAID controller modules. Controls and indicators The Battery Backup Units provides the following indicators: Power Lit (green). Power is being supplied to the Battery Backup Units. Charging Lit (green). The Battery Backup Units is being charged. Off. Fault Lit (amber). The Battery Backup Units has a failure. If the Fault LED is lit, replace the Battery Backup Units. Installing the Battery Backup Unit To install the Battery Backup Unit, slide the unit into the media tray and close the release handle. 14: IBM SAS RAID Controller Module This topic shows the mechanics of performing a physical installation of the Battery Backup Units. The Replacing a battery section of this document details the steps to take to prepare the IBM BladeCenter S SAS RAID Controller Module for a battery replacement. Battery Backup Unit installation into the front of the BladeCenter S chassis 23 Media tray Battery backup module Battery filler 1. Open the release handle (rotate the handle down). 2. Slide the battery backup unit into the media tray. 3. Close the release handle (rotate the handle up) Removing the Battery Backup Unit hardware To remove the Battery Backup Unit, open the release handle on the Battery Backup Unit and slide the bbattery Backup Unit out of the media tray. Important: If you are removing one or both Battery backup units from a BladeCenter S chassis that contains SAS RAID controller modules, refer to the IBM BladeCenter SAS RAID Controller Installation and User s Guide for additional steps that might need to be performed. Media tray Battery backup module Battery filler 1. Open the release handle (rotate the handle down) 2. Slide the battery backup unit out of the media tray. Chapter 2. Prerequisite hardware 15 24 16: IBM SAS RAID Controller Module 25 Chapter 3. Understanding the Telnet interface You can establish a Telnet session to retrieve information or to configure settings using the command line interface. You can perform a variety of installation and connectivity management tasks through an Ethernet connection using this interface. You can access the Telnet interface in one of two ways: v Advanced Management Module v Use the Command Line Interface on a network management workstation Establishing a Telnet session to RAID Controller You can establish a Telnet session using various methods. This topic describes how to establish a Telnet session to the RAID Controller using the Advanced Management Module. To establish a Telnet session to the RAID Controller using the Advanced Management Module complete the following steps: 1. Point your browser to where xxx.xxx.xxx.xxx is the IP address of the Advanced Management Module interface. The Enter Network Password window opens. If you have the Advanced Management Module connected to your network, log in using the network IP assigned to it. If you are using the default IP address your management system (the computer you are using to manage your IBM BladeCenter S components) must be physically connected through an Ethernet cable to the Advanced Management Module. Note: The default IP address for the Advanced Management Module is Enter the initial default user ID, USERID for the User Name. The user ID and password are case sensitive. 3. Enter the initial default password, PASSW0RD (the sixth character is a zero) for the Password and click OK. The Welcome window opens. 4. Select the timeout value of this Web session for the Inactive session timeout value and click Continue.The Login screen opens. 9. At the Login prompt, type the initial default user ID, USERID and press Enter. The user ID and password are case sensitive. The Password prompt displays. 10. At the Password prompt, type the initial default password, PASSW0RD (the sixth character is a zero). Copyright IBM Corp. 2008, 26 18: IBM SAS RAID Controller Module 11. Click OK. The Command Line Interface Shell screen opens. 27 Chapter 4. Installing the IBM BladeCenter S SAS RAID Controller Module This topic details the IBM BladeCenter S SAS RAID Controller Module installation and setup procedures. Before you begin, do the following: 1. Install a SAS Expansion Card (CFFv) for IBM BladeCenter (Part Number - 39Y9190) into each Blade server that you want to communicate with the RAID Controller. For detailed installation instructions, see The SAS Expansion Card (CFFv) for IBM BladeCenter Installation and Users Guide located in the Support directory on the support CD. 2. If you are upgrading ensure that your previously installed Advanced Management Module has the level of firmware that supports the RAID Controller. Note: If you log into the Advanced Management Module using the default IP ( ), your management system (the computer you are using to manage your IBM BladeCenter S components) must be physically connected through an Ethernet cable to the Advanced Management Module. 3. As part of the setup procedure, obtain four unused IP Addresses on the same subnet from your network administrator.Remember: Follow the guidelines for handling static sensitive devices. Once you have finished the prerequisite steps perform the following tasks: Copyright IBM Corp. 2008, 28 Installation and setup 1. Install a Battery Backup Unit in bay 1 of the Media Tray. If you have two SAS RAID Modules, install a second Battery Backup Unit in bay 2 of the Media Tray. Insert the CD into the laptop or PC you are using for your installation and follow the prompts given. Advanced Management Module A non-guided manual configuration using a direct connection to the Advanced Management Module. 29 Log into the Advanced Management Module and perform the rest of the setup tasks. Note: You will still need to configure integrated storage using the IBM BladeCenter Start Now Advisor, IBM Storage Configuration Manager, or RAID Controller command line interface. The IBM BladeCenter Start Now Advisor method After installation, you can configure the SAS RAID Modules using the IBM BladeCenter Start Now Advisor shipped with IBM BladeCenter S chassis. The Start Now Advisor is a configuration tool that helps you quickly connect to and configure components of the IBM BladeCenter S chassis. It provides step-by-step instructions and enables you to quickly and easily configure the Advanced Management Module and SAS RAID Modules, including setting storage options. To use the IBM BladeCenter Start Now Advisor: 1. Insert the IBM BladeCenter Start Now Advisor CD on a workstation that can communicate with the Advanced Management Module, and follow the instructions in the wizard. You must have the Advanced Management Module IP address and IP addresses for the RAID Controller and SAS Switch components of each IBM BladeCenter S SAS RAID Controller Module to complete IBM BladeCenter Start Now Advisor installation. Note: You must have the Advanced Management Module IP address and IP addresses for the RAID Controller and SAS Switch components of eachibm BladeCenter S SAS RAID Controller Module to complete the IBM BladeCenter Start Now Advisor installation. 2. After connecting to and doing initial inventory of the IBM BladeCenter S chassis, choose a configuration method to complete the setup. It is recommended that you use the Express configuration method. This gets you up and running quickest using intelligent defaults for many settings. You can optionally choose the Launch method which prompts you to launch additional consoles to complete the configuration process or the Import method, which allows you to import a configuration saved in another IBM BladeCenter Start Now Advisor session. The Advanced Management Module method After you install the IBM BladeCenter S SAS RAID Controller Module, you can log into the Advanced Management Module and set the parameters of the modules so that you can begin configuring your integrated storage. Note: Before you enter the POST and Ethernet switch parameters for your IBM BladeCenter S SAS RAID Controller Module, ensure that if you are running a storage configuration using spares, that spare matches the capacity, speed and type of the drives in the array for which it is used. 1. To log into the Advanced Management Module perform the following: a. Enter the IP address of the Advanced Management Module into the Web browser URL field. If you have the Advanced Management Module connected to your network, log in using the network IP assigned to it. If you are using the default IP address your management system (the computer you are using Chapter 4. Installing the IBM BladeCenter S SAS RAID Controller Module 21 30 to manage your IBM BladeCenter S components) must be physically connected through an Ethernet cable to the Advanced Management Module. Note: The default IP address for the Advanced Management Module is b. Enter the username and password.Note: Remember to log out when you have completed your session. If you experience any problems with setting these parameters, review the advanced verification procedures in the Troubleshooting section of this document. Installing IBM Storage Configuration Manager After completing initial configuration of your IBM BladeCenter S SAS RAID Controller Modules, you should install the IBM Storage Configuration Manager. IBM Storage Configuration Manager provides advanced support for management and monitoring of IBM BladeCenter storage. It also provides system health monitoring, device user management, and troubleshooting functions. The following is a summary and not meant to be used as primary installation instructions. For complete instructions and important compatibility notices, refer to the IBM Storage Configuration Manager Planning, Installation and Configuration Guide 22: IBM SAS RAID Controller Module 31 1. Navigate to downloads.html. 2. From the Choose Software list, select IBM Storage Configuration Manager and download the installer file. 3. Unpack the.zip or.tar installation file to a temporary directory or burn the ISO image to a CD. 4. Launch the installer and follow the on screen prompts. 5. When prompted to choose an install type, select SCM Full Install for all devices. 6. After you install the IBM Storage Configuration Manager, you are prompted to restart your workstation. TheIBM Storage Configuration Manager service starts automatically upon restart. 7. From the Start menu, launch the IBM Storage Configuration Manager 8.