Error message

Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home1/dezafrac/public_html/ninethreefox/includes/common.inc).

7

fc 300 danfoss manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:fc 300 danfoss manual.pdf
Size: 3157 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 21 May 2019, 14:36 PM
Rating: 4.6/5 from 605 votes.

Status: AVAILABLE

Last checked: 1 Minutes ago!

In order to read or download fc 300 danfoss manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

fc 300 danfoss manualInstallation, start up, and maintenance should be performed by qualified personnel only. Failure to perform installation, start up, and maintenance by qualified personnel could result in death or serious injury. High Voltage Frequency converts are connected to hazardous mains voltages. Extreme care should be taken to protect against s. These Operating Instructions can be used for all VLT AutomationDrive frequency. Danfoss VLT AutomationDrive FC 300 Converters Distributors. The well-structured. Reload to refresh your session. Reload to refresh your session. You can always update your selection by clicking Cookie Preferences at the bottom of the page. Please do not offer the downloaded file for sell only use it for personal usage. Looking for other manual? For this no need registration. May be help you to repair. You could suffer a fatal electrical shock. Instead, contact your nearest service center. Note! To open downloaded files you need acrobat reader or similar pdf reader program. In addition, Also some files are djvu so you need djvu viewer to open them. These free programs can be found on this page: needed progs If you use opera you have to disable opera turbo function to download file. If you cannot download this file, try it with CHROME or FIREFOX browser. Translate this page: Relevant OTHER forum topics: Danfoss EDT30 ketpontos hofokszabalyzo, nem lehet szabalyozni Hello! Kontakt hibaval kezdodott, most mar nem allithato a kapcsolasi hofok. A hofokot azt jol meri. Ha valakinek errol van infoja, rajz vagy valami.A benne levo iC-k.You can write in English language into the forum (not only in Hungarian). As an essential manufacturer of HVAC systems, AAON is doing all we can for our customers that have AAON equipment on critical infrastructure and those customers that need new equipment or parts for critical infrastructure. Find your purpose. Apply online today... Read More. AAON water-source heat pumps do more than the conventional water-source heat pump.http://www.speedski-cz.cz/userfiles/fckeditor/endobase-olympus-manual.xml

    Tags:
  • fc 300 danfoss manual, danfoss fc 300 manual pdf, danfoss fc 300 programming manual, danfoss vlt fc 300 manual, danfoss fc 300 profibus manual, danfoss fc 300 service manual, danfoss vlt automationdrive fc 300 manual, danfoss fc 300 user manual, danfoss vlt fc 300 manual pdf, fc 300 danfoss manual, fc 300 danfoss manual transfer switch, fc 300 danfoss manual transmission, fc 300 danfoss manual user, fc 300 danfoss manual diagram, danfoss fc 300 manual.

They are engineered to handle complicated applications such as 100 Outside Air, Variable Air Volume, and Single Zone VAV with ease... Read More A few features of the lab include supply, return, and outside sound testing at actual load conditions, testing of up to a 300 ton air conditioning system, testing of up to a 540 ton chiller system, and... Read More Double wall rigid polyurethane foam insulated cabinet construction and direct drive backward curved plenum fans allow RQ series units to have quiet... Read More.http://kardelendalgicpompa.com/uploadfiles/endoflator-service-manual.xml VLT AUTOMATIONDRIVE FC 302 - DANFOSS DRIVES The VLT AutomationDrive FC 302 from Danfoss is a single drive to control all standard servomotors procedures of.VLT AutomationDrive FC 301 DC Drives pdf manual download. Danfoss, Model: FC-301 IP55 4kW 400V 3ph AC Inverter Drive, C1 EMC. Danfoss VLT AutomationDrive FC Download the Danfoss VLT AutomationDrive FC 301 Manual. Get Latest Price from the seller Our company is engaged as manufacturer, supplier, wholesaler, retailer and trader of products such as PLC Panel, Programmable Logic Relay, Commercial Drive, Control Panel, Power Supply Unit, Optical Encoder and more. We also provide AC Drive Repairing Service and more. From basic machine control applications to processes that require extremely complex sub micron positioning, machine vision, lighting, safety, automation and robots, we have the products and expertise to deliver a solution that fits your needs. With products from industry leading suppliers and experienced technical support, let our company make your automation project a successful one. We are known for the complete quality controlling in our products as well as work with the help of our quality controlling team.Get Best Deal I agree to the terms and privacy policy All rights reserved. This page requires Javascript. Modify your browser's settings to allow Javascript to execute. See your browser's documentation for specific instructions. Are you sure you want to switch accounts? Are you sure you want to switch locations? The branches are supplied with more than 50,000 SKU products on a continual basis from our distribution center in Wilkes-Barre, PA. Our manufacturing plant in Andrews, SC is the source for more than 1,700 Sid Harvey brand name products, both new and re-manufactured. It also has a substantial presence in aftermarket parts and service, energy, mine dewatering, oil sands exploration, production drilling, and down-hole instrumentation.https://www.thebiketube.com/acros-dexta-hydraulic-manual Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful. This means that every time you visit this website you will need to enable or disable cookies again. Who We Are? Danfoss Danfoss engineers technologies that empower the world of tomorrow to build a better future. Energy efficient technologies empower smart communities. Crompton Greaves Crompton Greaves Consumer Electricals Ltd.Schneider Electric As a global specialist in energy management and automation with operations in more than 100 countries, we offer integrated energy solutions across multiple Locations. Allen-Bradley Improve productivity and flexibility with the Allen-Bradley product line, brought to you by Rockwell Automation. A leader in innovation and quality Delta With modern power electronics and advanced microprocessor technology, Delta's AC Motor Drives are able to efficiently control motor speed, improve machine. We Provide Innovative Business Solutions That Will Positively Impact Your Business Get Free Consultation Corporate Blog An independent division which also caters the requirement of those customers who are using very Old or Obsolete series of VFD, PLC,HMI or any other automation products. SWASTIK SERVICES Provides services of Repairing in all make AC Drives. Services: Sync music, Manage music, Recover missing metadata, Record CDs Download MediaMonkey Now Buy MediaMonkey Gold Get Addons Never use any other conversion tool again. Find Music File Converter Mp3 Mp3 converter www.easypdfcombine.com Merge And Convert Files Into PDFs For Free With EasyPDFCombine App. Very convenient unlike the other sites, no pop-up windows or redundant pics. It’s constantly improving and developing. Both file upload and download are very convenient. Services: Sync music, Manage music, Recover missing metadata, Record CDs Download MediaMonkey Now Buy MediaMonkey Gold Get Addons Never use any other conversion tool again. For the voice com munication, it can supp ort selected pre-emphasis, s quelch and audio am plifier. The applic ation of two-point m odulation with good low-frequency response in the ra dio also m akes it a competitive choi ce for audio applications. Compact dimension an d wide range DC support make it flexible to use. S t a n d a r d D B 9 i n t e r f a c e S t a n d a r d D B 1 5 i n t e r f a c e Stan dard DB9 and Standard DB15 is only used for voice transm ission. The pin definition is shown in T able 2. This line has an internal pull-up to 5V. Also able to work as simulated serial port for parameter setting. MIC IN 7 7 Microphones input. Can directly connect to electrets MIC, the DC voltage of this pin should lower than 3.5V, then MIC transmission can be activated. SWITCH 8 8 Control output, 5V high level output when active Also able to work as simulated serial port for parameter setting. S PK is effective when Pin 7 connect to MIC or GND, ( MIC PIN power than 3.5V TXD ( Radio ) - 10 The serial data is outpu t from this pin, used for radio parameter setting, 5V TTL Signal is output from radio. RXD ( Radio ) - 1 1 The serial data is input to this pin, used for radio parameter setting, 5V TTL Signal is input into radio CH1 - 12 Select channel by D ip switch; the low bit of 4-bit binary code. A vailable when channel control mode is programmed as “by Dip switch” CH2 - 13 Select channel by Dip switch; the second b it of 4-bit binary code. CH3 - 14 Select channel by Dip switch; the third bit of 4-bit binary code. CH4 - 15 Select channel by Dip switc h; the fort h bit of 4-bit binary code. 4 Application Instruction Functions of PC Personal C omputer) software, hereafter called “ FC-302 QuickSet v0.1.12 ”, will be illustrated. Main goal of this i nstruction is to save time for user by supporting exa ct usage of the software, at the same time, give a help to user who wants to utilize the radio for another app lications. T his programming softw are enables the various param eters of FC-302 to be read, m odified, programmed and prin ted. 4.1 Hardwar e Installation T o apply PC software to radio a pplication, FC-302 Qui ckSet En v0.1.12, pro gramming cable, pro gramming kit and PC are needed. In this chapter, instruction fo r connection of the equipment w ill be illustrated. Es pecially, in input chann el signal, signal input m ethod for Rx,Tx frequency, Rx,Tx option such as CTCS S, DCS, scan and bandwidt h is explained specifically. In addition, sy stem option s uch as selection of squelc h type, data value sett ing for power saving mode, Tx time out tim e, scan option is detaile d. 4.2.1 Overal l V iew Pin 6 (BUSY) and Pi n 8 (Switch) of DB15 co nnector work as TX end and RX end of sim ulated serial port in the first 2 minutes after the radio power on. The CON po rt is with characteristics of 9600bps, 8N1, TTL. If no valid comm and is sent from PC, the por t will be disabled from serial simulation function a nd return to normal BUSY and Switch function. Initially, click on the sh ortcut of PC software and t hen the following wind ow shows up. The CON port is with characteristi cs of 9600bps, 8N1 and click “Open” as picture shows. As the followin g picture: W arning: 1. I f there is no r ead or write operations in first 30 seco nds after the radio is powered up or Level 0 is for fully ope n mute. The audio signal wi ll continuously transm it. The feature is not available for high speed vo ice transmission. The judging c ondition is long perio d of 260Hz, sine wave 3 00 Ms. 4.2.2.5 Scan This feature allow user to decide sca n mode and establis h chann el scan list. Radio will start to detect channels and stay on each channel for at leas t 100ms according to the established scan sequence. If a signal or conversation is dete cted on any channels in sca n list, the radio will stop on t hat channel and you will monitor the signal or hear the conver sation. When the si gnal or conversation is disa ppeared, the radio conti nues to scan. 4.2.3 System Configuration 4.2.3.1 Chan nel Control Mode Radio’ s channel can be selected by in ner Dip(4) switch(HW) or serial com mand inputted from our PC software(SW). Only in SW control mode, channel can be selected in “Channel” colu mn. 4.4.3.2 W orking Channel In this column, user selec t current channel for working. Once the power supply become hi gher than High volts, the ra dio can start to work ag ain. The recommended Low volt is lower than 9V. The recommend High v olt is 13.8V. 4.2.3.3.2 T X Protect ion This feature, when ena bled, limit the am ount of time that user ca n continuously tra nsmit. Th e time can be set from 1 second to 60 seconds. Whe n timeout, radio will r elease PTT pinout. If user want to transm it again, he or she have to wait delay time (set by “stop when timeout”) after t he radio released PTT. 4.2.3.3.3 De-emphasis V olume FC-302 U2 radio out put voice via SPK Pin with 9 le vels volume. Us er is able to select appropri ate volume for the connected external speaker in this feature. 4.2.3.3.4 Pow er Save Mode Here, you can enable Pow er save mode or disable. When enabled, radio will aut omatically switch betw een Sleep and Standby to low er power consumption. T he time of Sleep and Standby can be set in “Power save time”. However, for supporti ng fast attack tim e between TX and RX, the radio will keep in RX mode and the PLL keep working eve n in power save m ode. Only the interm ediate frequency circuit is off. Th at means 1 equals to 40ms, 2 equals to 80,. 15 equals to 60 0ms. 4.2.3.3.5 Car rier Detect Busy Signal This feature is to s et active level of BUSY Pin, high or lo w. The status is tra nsferred to user for the connection with exte rnal devi ces. 4.2.3.4 Third Column Featur es 4.2.4.4.1 Audio-out Output wave f or Audio-out can be selected as square wa ve or sin wave. 4.2.4.4.2. Side T one When enabled, user can hear his own voice while trans mitting voice.If p riority scan is enabled, radio will sca n the prioritized channel with mo re times. Prioritized ch annel is the working channel before the scan. If you click here, user does not need t o wait the 2 minutes. 5 Maintenance and Repair 5.1 Dimensions Fig.17 Top View T o replace the Main Board Assembly: 1. Reverse the steps taken to rem ove the Main Board Assembly. The device su pports The highest g ain of antenna is 5.0 dBi. These applications include: However, servo equipment is expensive; it is difficult to commission and requires additional cabling. And, as servo drives do not work with open loop control systems, there is a high failure rate. Many applications do not require the high dynamic performance offered by a servo drive. An alternative was to use an AC drive. But, until now, an additional internal or external module or an encoder on the motor was required. The Integrated Motion Controller (IMC) is functionality that enables an AC drive to perform high-precision positioning and synchronization operations without the need for additional modules or hardware.It works with all conventional motor technologies, with closed loop or open loop control, and offers sensorless homing with torque detection. Drives are adapted to the applications through simple parameterization. This means that knowledge of servo technology or programming languages is not required. As no encoder or additional cables are needed, engineering, installation and commissioning time and costs can be reduced. IPA-certified. Nevertheless, I like this one more than others. Very convenient unlike the other sites, no pop-up windows or redundant pics. Services: Sync music, Manage music, Recover missing metadata, Record CDs Download MediaMonkey Now Buy MediaMonkey Gold Get Addons Never use any other conversion tool again. The operating guide is intended for use by qualified personnel. Read and follow the instructions to use the frequency converter safely and professionally, and pay particular attention to the safety instructions and general warnings. Always keep this operating guide available with the frequency converter. VLT is a registered trademark. 1.2 Additional Resources Other resources are available to understand advanced frequency converter functions and programming. Supplementary publications and manuals are available from Danfoss. See 3Adocumentation2Csegment3Adds for listings. 1.3 Manual and Software Version This manual is regularly reviewed and updated. All suggestions for improvement are welcome. Table 1.1 shows the manual version and the corresponding software version. 1.4 Product Overview Intended Use The frequency converter is an electronic motor controller intended for: Regulation of motor speed in response to system feedback or to remote commands from external controllers. A power drive system consists of the frequency converter, the motor, and equipment driven by the motor. System and motor status surveillance. The frequency converter can also be used for motor overload protection. Depending on the configuration, the frequency converter can be used in standalone applications or form part of a larger appliance or installation. The frequency converter is allowed for use in residential, industrial, and commercial environments in accordance with local laws and standards. NOTICE In a residential environment, this product can cause radio interference, in which case supplementary mitigation measures can be required. Foreseeable misuse Do not use the frequency converter in applications which are non-compliant with specified operating conditions and environments. Ensure compliance with the conditions specified in chapter 8 Specifications. NOTICE The output frequency of the frequency converter is limited to 590 Hz. For demands exceeding 590 Hz, contact Danfoss. MG33AT02 7 Introduction Operating Guide 1.5 Type Approvals and Certifications 1 1 The following list is a selection of possible type approvals and certifications for Danfoss frequency converters: 089 NOTICE The specific approvals and certification for the frequency converter are on the nameplate of the frequency converter. For more information, contact the local Danfoss office or partner. For more information on UL 508C thermal memory retention requirements, refer to the section Motor Thermal Protection in the product-specific design guide. For more information on compliance with the European Agreement concerning International Carriage of Dangerous Goods by Inland Waterways (ADN), refer to the section ADN-compliant Installation in the product-specific design guide. CAUTION Indicates a potentially hazardous situation that could result in minor or moderate injury. It can also be used to alert against unsafe practices. NOTICE Indicates important information, including situations that can result in damage to equipment or property. 2.2 Qualified Personnel Correct and reliable transport, storage, installation, operation, and maintenance are required for the troublefree and safe operation of the frequency converter. Only qualified personnel are allowed to install and operate this equipment. Qualified personnel are defined as trained staff, who are authorized to install, commission, and maintain equipment, systems, and circuits in accordance with pertinent laws and regulations. Also, the qualified personnel must be familiar with the instructions and safety measures described in this manual. 2.3 Safety Precautions WARNING HIGH VOLTAGE Frequency converters contain high voltage when connected to AC mains input, DC supply, or load sharing. Failure to perform installation, start-up, and maintenance by qualified personnel can result in death or serious injury. Only qualified personnel must perform installation, start-up, and maintenance. Before performing any service or repair work, use an appropriate voltage measuring device to make sure that there is no remaining voltage on the frequency converter. WARNING UNINTENDED START When the frequency converter is connected to AC mains, DC supply, or load sharing, the motor may start at any time. Unintended start during programming, service, or repair work can result in death, serious injury, or property damage. The motor can start via an external switch, a fieldbus command, an input reference signal from the LCP, or after a cleared fault condition. To prevent unintended motor start: Disconnect the frequency converter from the mains. Completely wire and assemble the frequency converter, motor, and any driven equipment before connecting the frequency converter to AC mains, DC supply, or load sharing. WARNING DISCHARGE TIME The frequency converter contains DC-link capacitors, which can remain charged even when the frequency converter is not powered. High voltage can be present even when the warning LED indicator lights are off. Failure to wait the specified time after power has been removed before performing service or repair work can result in death or serious injury. Stop the motor. Disconnect AC mains and remote DC-link power supplies, including battery back-ups, UPS, and DC-link connections to other frequency converters. Disconnect or lock PM motor. Wait for the capacitors to discharge fully. The minimum waiting time is specified in Table 2.1 and is also visible on the product label on top of the frequency converter. Ensure the correct grounding of the equipment by a certified electrical installer. WARNING EQUIPMENT HAZARD Contact with rotating shafts and electrical equipment can result in death or serious injury. Ensure that only trained and qualified personnel perform installation, start-up, and maintenance. Ensure that electrical work conforms to national and local electrical codes. Follow the procedures in this guide. WARNING UNINTENDED MOTOR ROTATION WINDMILLING Unintended rotation of permanent magnet motors creates voltage and can charge the unit, resulting in death, serious injury, or equipment damage. Ensure that permanent magnet motors are blocked to prevent unintended rotation. CAUTION INTERNAL FAILURE HAZARD An internal failure in the frequency converter can result in serious injury when the frequency converter is not properly closed. Ensure that all safety covers are in place and securely fastened before applying power. Check the packaging and the frequency converter visually for damage caused by inappropriate handling during shipment. File any claim for damage with the carrier. Retain damaged parts for clarification. Failure to meet requirements for ambient conditions can reduce the lifetime of the frequency converter. Ensure that requirements for air humidity, temperature, and altitude are met. Vibration and shock The frequency converter complies with requirements for units mounted on the walls and floors of production premises, and in panels bolted to walls or floors. MG33AT02 11 Mechanical Installation Operating Guide Cooling Ensure that top and bottom clearance for air cooling is provided. See Illustration 3.2 for clearance requirements.Failure to take proper lifting precautions increases risk of death, serious injury, or equipment damage. Never walk under suspended loads. To guard against injury, wear personal protective equipment such as gloves, safety glasses, and safety shoes. Be sure to use lifting devices with the appropriate weight rating. To determine a safe lifting method, check the weight of the unit, see chapter 8.9 Power Ratings, Weight, and Dimensions. The angle from the top of the drive module to the lifting cables has an impact on the maximum load force on the cable. This angle must be 65 or greater. If necessary, plan for a hoist, crane, or forklift with the appropriate rating to move the unit. For lifting, use hoist rings on the unit, when provided.The frequency converter allows side-by-side installation. 2. Locate the unit as near to the motor as possible. Keep the motor cables as short as possible. 3. Mount the unit vertically to a solid flat surface or to the optional backplate to provide cooling airflow. 4. Use the slotted mounting holes on the unit for wall mount, when provided. WARNING INDUCED VOLTAGE Induced voltage from output motor cables that run together can charge equipment capacitors, even with the equipment turned off and locked out. Failure to run output motor cables separately or to use shielded cables could result in death or serious injury. Run output motor cables separately, or Use shielded cables. CAUTION SHOCK HAZARD The frequency converter can cause a DC current in the PE conductor. Failure to follow the recommendation may lead to the RCD not providing the intended protection. When a residual current-operated protective device (RCD) is used for protection against electrical shock, only an RCD of Type B is allowed on the supply side. Overcurrent protection Extra protective equipment, such as short-circuit protection or motor thermal protection between frequency converter and motor, is required for applications with multiple motors. Input fusing is required to provide short-circuit and overcurrent protection. If not factorysupplied, the installer must provide fuses. See maximum fuse ratings in chapter 8.7 Fuses and Circuit Breakers. Wire type and ratings All wiring must comply with local and national regulations regarding cross-section and ambient temperature requirements. Power connection wire recommendation: Minimum 75 C (167 F) rated copper wire. See chapter 8.1 Electrical Data and chapter 8.5 Cable Specifications for recommended wire sizes and types. 4.2 EMC-compliant Installation To obtain an EMC-compliant installation, follow the instructions provided in chapter 4.3 Grounding, chapter 4.4 Wiring Schematic, chapter 4.5 Motor Connection, and chapter 4.7 Control Wiring. 4.3 Grounding WARNING LEAKAGE CURRENT HAZARD Leakage currents exceed 3.5 ma. Failure to ground the frequency converter properly could result in death or serious injury. For electrical safety Ground the frequency converter in accordance with applicable standards and directives. Use a dedicated ground wire for input power, motor power, and control wiring. Do not ground 1 frequency converter to another in a daisy-chain fashion (see Illustration 4.1). Keep the ground wire connections as short as possible. Follow motor manufacturer wiring requirements. Minimum cable cross-section for the ground wires: 10 mm 2 (7 AWG). MG33AT02 13 Electrical Installation Operating Guide 130BC FC 1 FC 2 FC 3 PE 4 4 FC 1 FC 2 FC 3 PE Illustration 4.1 Grounding Principle For EMC-compliant installation Establish electrical contact between the cable shield and the frequency converter enclosure by using metal cable glands or by using the clamps provided on the equipment (see chapter 4.5 Motor Connection). Use high-strand wire to reduce burst transient. Do not use pigtails. NOTICE POTENTIAL EQUALIZATION Risk of burst transient when the ground potential between the frequency converter and the control system is different. Install equalizing cables between the system components. Recommended cable cross-section: 16 mm 2 (6 AWG). For installation instructions, refer to the VLT Safe Torque Off Operating Guide. For FC 301, terminal 37 is only included in enclosure size A1. MG33AT02 15 4 4 Electrical Installation Operating Guide 6 e30bf u v w 16 L1 L2 L3 PE PE PLC. 10 Mains cable (unshielded). 2 Minimum 16 mm 2 (6 AWG) equalizing cable. 11 Output contactor. 3 Control cables. 12 Cable insulation stripped. 4 Minimum 200 mm (7.9 in) between control cables, motor cables, and mains cables. 13 Common ground busbar. Failure to isolate power, motor, and control cables can result in unintended behavior or reduced performance. Minimum 200 mm (7.9 in) clearance is required between power, motor, and control cables. U V W BD Motor Connection WARNING INDUCED VOLTAGE Induced voltage from output motor cables that run together can charge equipment capacitors, even with the equipment turned off and locked out. Failure to run output motor cables separately or use shielded cables could result in death or serious injury. Comply with local and national electrical codes for cable sizes. For maximum wire sizes, see chapter 8.1 Electrical Data. Follow motor manufacturer wiring requirements. Do not wire a starting or pole-changing device (for example Dahlander motor or slip ring asynchronous motor) between the frequency converter and the motor. Procedure for grounding the cable shield 1. Strip a section of the outer cable insulation. Illustration 4.4 Motor Connection Illustration 4.5 shows mains input, motor, and grounding for basic frequency converters. Actual configurations vary with unit types and optional equipment. L1 L2 L DC BR- B M A I N S RELAY 1 RELAY 2 130BF Position the stripped wire under the cable clamp to establish mechanical fixation and electrical contact between the cable shield and ground. 3.