englander pellet stove service manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:englander pellet stove service manual.pdf
Size: 2666 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 18 May 2019, 18:45 PM
Rating: 4.6/5 from 636 votes.
Status: AVAILABLE
Last checked: 8 Minutes ago!
In order to read or download englander pellet stove service manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
englander pellet stove service manualAlot of our customers have found them helpful, particularly if you'd rather learn from seeing (on a video) rather than reading (from a manual). They're broken into short chapters, such as auger motor replacement, weekly cleaning, etc. PLEASE provide the 1) Model Number 2) Serial Number 3) Manufacture Date 4) Date of Purchase of your stove AND your 1) Name 2) Phone Number 3) State you live in, so that we may find your registration in our system and better assist you. Thank you! We will respond asap. Always feel free to contact us if you need any more info. I cannot think of any other company that does that. You people are GREAT.Canada-- If you do not agree to these terms and conditions, please do not use this site. The collective work includes works that are licensed to England's Stove Works, Inc. Copyright 2018, England's Stove Works, Inc.You further agree not to change or delete any proprietary notices from materials downloaded from the site. To the fullest extent permissible pursuant to applicable law, England's Stove Works, Inc.England's Stove Works, Inc.England's Stove Works, Inc.Some states do not permit limitations or exclusions on warranties, so the above limitations may not apply to you. Applicable law may not allow the limitation of exclusion of liability or incidental or consequential damages, so the above limitation or exclusion may not apply to you. England's Stove Works, Inc.If your credit card has already been charged for the purchase and your order is cancelled, England's Stove Works, Inc.These terms and conditions, or any part of them, may be terminated by England's Stove Works, Inc.The provisions relating to Copyrights, Trademark, Disclaimer, Limitation of Liability, Indemnification and Miscellaneous, shall survive any termination. You agree that jurisdiction over and venue in any legal proceeding directly or indirectly arising out of or relating to this site (including but not limited to the purchase of England's Stove Works, Inc.http://midlandpipe.com/userfiles/disadvantages-of-manual-inventory-systems.xml
- Tags:
- englander pellet stove service manual, englander pellet stove owner s manual, englander pellet stove 25-pdvc owners manual, englander pellet stove service manual, englander pellet stove service manual on youtube, englander pellet stove service manual electric, englander pellet stove service manual pdf, englander pellet stove service manuals.
Any cause of action or claim you may have with respect to the site (including but not limited to the purchase of England's Stove Works, Inc.England's Stove Works, Inc.'s failure to insist upon or enforce strict performance of any provision of these terms and conditions shall not be construed as a waiver of any provision or right. Neither the course of conduct between the parties nor trade practice shall act to modify any of these terms and conditions. England's Stove Works, Inc.Impersonation of others, including a England's Stove Works, Inc.You may not upload to, distribute, or otherwise publish through the site any content which is libelous, defamatory, obscene, threatening, invasive of privacy or publicity rights, abusive, illegal, or otherwise objectionable which may constitute or encourage a criminal offense, violate the rights of any party or which may otherwise give rise to liability or violate any law. You may not upload commercial content on the site or use the site to solicit others to join or become members of any other commercial online service or other organization. You acknowledge that by providing you with the ability to view and distribute user-generated content on the site, England's Stove Works, Inc.However, England's Stove Works, Inc.However, even if the third party is affiliated with England's Stove Works, Inc., England's Stove Works, Inc.These linked sites are only for your convenience and therefore you access them at your own risk. Nonetheless, England's Stove Works, Inc. Save These Instructions.CAUTION: Please read this entire manual before installation and use of this pellet fuel burning room heater. Keep children, furniture, fixtures and all combustibles away from any heating appliance.Mobile Home Use: These freestanding pellet units are approved for mobile home or doublewide installation with outside combustion air hook-up. See “Flue System” section of manual.http://agro-avangard.ru/public/disadvantages-of-manual-input-devices.xml Mobile home installation should be in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24. WARNING: Do Not Install in Sleeping Room Thank you for purchasing this. Page 2 A letter from our Technical Support department. Thank you for purchasing this fine product from England’s Stove Works! England's. Page 3 IMPORTANT INFORMATIONCall your Homeowner’s InsuranceAny ashes should bePage 6 FLUE SYSTEM. Caution: Follow the pipe manufacturer’s installation instructions and directions forWhen venting the stove through the ceiling, the pipe is connected the same as through the. Page 8 Freestanding Pellet InstallationPage 9 OPERATING INSTRUCTIONSPage 10 any firestarter on any hot surface or hot coals. Never use gasoline, lantern fuel, kerosene,Page 11 DAILY OPERATIONThis stove has a (approximately)Page 13 Annual CleaningPage 14 NOTE: Follow the same procedure to work on the bottom auger, with the exception that theThis board offers a wideControl BoardThe following accessories can be added to your unit at anytime after purchase; however, letIllustration 4Page 21 TROUBLE-SHOOTING GUIDERetain for your files. Page 23 WARRANTY REGISTRATION for England’s Stove Works. Page Count: 3 The Englander 25-PDV Pellet stove is the perfect way to supplement the heat Englander 2,200. Sq. Ft. Pellet Stove Specifications, Parts, Manuals, Help, FAQ. England's Stove Works StoveStandard or 55-TRP10, 25-PDV(E), 55-SHP22, 55-TRP22, or American Heritage, 25-PDVP,Englander 25 Pdv Pellet Stove Manual. File Type Extension: pdf. PDF Version: 1.4. Linearized: No. Author: Softplicity. Subject. Page Count: 3. Page Mode: UseOutlines. Description. Creator: Softplicity. Title: Englander 25 Pdv Pellet Stove Manual. Creator Tool: Softplicity. Keywords. Producer: Softplicity. There are, however, a few insider secrets that will help you prolong the life of your pellet stove and reduce your need for costly repairs. Here are five tips to keep your pellet stove running in top shape.http://fscl.ru/content/boss-pw-10-v-wah-manual The main reason for choosing softwood pellets is their exceptionally low ash volume. While it is possible to find hardwood pellets with low ash content, it is more common to find this in softwood pellets. In fact, single-source pellets, such as those made from 100 douglas fir, boast some of the lowest ash values and highest heat values that can be obtained from pelletized wood. This means less cleanup, less wear and tear on your stove, and ultimately a lower heating bill as a result of the increased efficiency. That dust is called “fines” and should be avoided in your stove. Fines collect at the base of the hopper and will eventually occupy the entire feeder opening. While these dust particles may not produce a noticeable effect after one or two bags, after a full heating season and hundreds of bags worth of these fines, you may begin to notice decreasing performance from your pellet stove. Serious mechanical problems, such as failed auger bushings and burnt-out auger motors can result from excessive fines that are left unchecked in some models. Other serious safety hazards, such as hopper fires.Periodically open the mechanical cabinet of the stove to check for fines under the auger motor. If you find that fines have collected here, there is a good chance that your auger bushing has worn and will need to be replaced. When the exhaust cannot escape to the outside air quickly enough, it creates back pressure which lowers the amount of air that can enter the pellet stove, this will decrease the efficiency of your stove. This will save you a lot of money in the long run on fuels and replacement parts. However, it is a good idea to first run the stove on “HIGH” to get your space up to temperature as quickly as possible, and then allow the stove go into a standby operation where is oscillates to a lower heat range for some specified amount of time, usually 35 minutes or so, before either shutting down or ramping back up based upon the demand for heat.http://oud-dijk.com/images/compact-4-5-door-manual-aircon-cdmr.pdfHumidity can easily enter your stove when it is not in use during the off-season. This can cause the inside of the stove to become wet and sticky, making it difficult to clean. Additionally, when water and ash mix, carbonic acid is created which will corrode the steel in the body of your stove. If you live in a wet climate or near the water, place a container of “Damp-Rid” inside your stove to collect humidity. Power outages and electrical storms can happen frequently in the Summer, and control boards can be easily damaged by these events. For earlier PelPro models, the name of the control board is printed on the face of the control board. Complete the form below and your local dealer will be in touch. Please upgrade your browser for a better experience. Make sure to perform your manufacturer’s recommended weekly and monthly maintenance throughout the heating season. In addition, we recommend having your stove cleaned and serviced by a processional once a year (or every 2-3 tons, whichever comes first). If you need a recommendation for a reliable, stove tech, give us a call at 1-800-PELLETS. If any of those settings are out of whack, you will likely experience problems, even with the highest quality pellets. But whether you’re burning pellets for the first time in a new stove, firing up your system at the start of a new season, or switching to a new brand of pellets or a new shipment, here is a quick reference guide for troubleshooting some common burn quality issues. See how serious we are in our Quality Guarantee Like or Follow Us to see the latest industry news and our latest promotional discounts. Please check your inbox, and if you can’t find it, check your spam folder to make sure it didn't end up there. Please also check your spam folder. We wish you many years of safe heating pleasure with your new heating appliance. See “Flue System” section of manual. Follow all manufacturer’s instructions when using smoke or Carbon Monoxide detectors. Refer to this owner’s manual for all clearances to combustible materials. We are nearly always able to help “walk you through” any repairs, problems or questions you may have. Also be sure to follow all other maintenance instructions as outlined in your Owner’s Manual and the Instructional DVD included with the unit. Failure to remove ashes from this area before each burn can cause smoke-back and serious damage to your stove, and can void your warranty. We will not be held responsible for poorly maintained units, including excess ash in the burn pot area. If you install your stove in the same room as the Cold Air Return from your home’s Central Furnace, you must place your stove at least 20 feet (20’) from the Cold Air Return. We recommend you open an outside window slightly, and never close the door that leads from this room to the rest of your home. When power is restored, press the ON button to restart your unit, and let the unit run for at least 30 minutes. Do NOT restart your unit before calling Technical Support at (800) 245-6489. Call your Homeowner’s Insurance representative for inspection of your stove’s installation. The stove should automatically shut itself off after the 20-minute dry run. Burning pea coal, cherry pits, or anything other than wood pellets will void your warranty. Pellets with high ash content will burn dirty and require the unit to be cleaned more often. This unit is designed for use with ?” diameter pellet fuel. Using pellets longer than 2” can bind the auger and require frequent manual removal. Keep sawdust out of the unit. For installations over 4000 ft. Even though this pipe interlocks, it is a good idea to seal all connections with high temperature silicone ( AC-RTV3 ). Use at least three screws to secure the pipe to this unit’s exhaust blower. Also, if you do not use U.L.-approved twist-lock pellet pipe, be sure to use U.L.-approved Pellet Vent pipe, and fasten each joint of the pipe with at least three screws. Be sure to secure the pipe to the unit with a clamp or aluminum tape. The outside end should be covered (screened) to prevent any foreign matter from entering the system. Our Part Number PU-OAK (Outside Air Kit with flex pipe) can be used. The area to the right and left of the burn pot is for ash storage; keep the air holes in the burn pot clean for a more efficient burn. Check your exhaust system frequently. Refer to “Ash Removal and Disposal” section. The minimum floor protector for this unit is 36” x 36” which should give you at least six inches (6”) of protection at the rear and each side, and six inches (6”) minimum in the front of the unit. At fifteen feet (15’), the pipe should be increased to four inch (4”) pellet vent pipe. Any ashes should be kept in an airtight metal container and not disposed of until they are completely cooled. Do not allow liquid or ANY foreign materials on or inside your unit. Shut your unit down and cover it when painting, construction or similar activity is taking place. Wipe and clean your unit after any construction is done in your home, or if any foreign material gets on or inside your unit. You may also need to remove the rear and side cover plates to your unit (unplug unit first) and vacuum and clean the motors and inside of your unit. Be sure to check local codes, and call Technical Support at (800) 245-6489 if you have any questions. Never use gasoline, lantern fuel, charcoal lighter fluid, diesel fuel or any other flammable liquid to start the fire. If you manually start your unit, recommended fire starter materials are: Wax-impregnated wood chips, cardboard cubes or firestarter chips designed for pellet stoves (see section on Manually Starting Unit). Follow any manufacturer’s directions for these products, and NEVER place any firestarter on any hot surface or hot coals. Never apply any firestarter products of any kind to a hot surface or hot coals. For basement installations, a 3” (three inch) pipe and coupler must be used for Outside Combustion Air, and a minimum clearance of 3’ (three feet) must be maintained from the ground to the pellet vent exhaust pipe outside the dwelling. Keep in mind Example: After the 2 nd elbow used, have 6’ (six feet) of vertical rise before terminating your vent pipe. The top auger runs intermittently and drops pellets to the bottom auger; the bottom auger runs constantly and simply pushes the pellets forward to the burn pot. The control board (“Heat Range”) setting determines the top auger feed rate. This will start the upper auger, bottom auger and exhaust blower. The room air blower will start later as the stove reaches the pre-set blower temperature (see “Control Board” section for further explanation). Be sure to “dry run” your unit for 20 minutes before connecting it to the flue (it should stop automatically after 20 minutes). If this is the case with your stove, follow these instructions to return the plate to its proper position. At this point, the plate will lean forward (toward the front of the stove) slightly, and will come in contact with the front of the stove above the door. Your unit requires periodic maintenance and cleaning (refer to manual). Failure to maintain your unit may lead to a variety of problems, including but not limited to smoke spillage into the home. England’s will not be liable for consequential or indirect damages to property or persons resulting from the use of this product. If this unit is connected to the flue system other than the way explained in this manual, it will not function properly. Example: After the 2 nd elbow used, have 6’ (six feet) of vertical rise before terminating your vent pipe. Do not use “B” vent gas pipe or galvanized pipe with this unit. The pellet pipe is designed to disassemble for cleaning and should be checked several times during the burning season — pellet vent pipe is not furnished with the unit and must be purchased separately. For installations over 4000 ft. Do not install a flue damper of any kind in this system, and do not connect this unit to a flue system serving another heating appliance. If the exhaust adapter is at least eighteen inches (18”) above ground level, a straight section of pellet pipe can be used to initially pass through the wall (see Illustration 1 ). Your dealer or our factory should be able to provide you with a kit that will handle most of this installation, which will include a wall thimble that will allow the proper clearances through a combustible wall. Once outside the structure, a three-inch (3”) clearance should be maintained to the outside wall and a clean out tee should be placed on the pipe that extends through the wall. We recommend a minimum of three feet (3’) of vertical pipe with a 90-degree turn away from the house. At this point, a one-foot (1’) section and horizontal cap will complete the installation (see Illustration 1 ). If you live in an area that has heavy snowfall, it is recommended the installation be taller than three feet (3’) to get above the snowdrift line. However, we recommend basement installation be performed only by a professional installer. For basement installations, a 3” (three inch) pipe and coupler must be used for Outside Combustion Air, and a minimum clearance of 3’ (three feet) must be maintained outside the dwelling from the ground to the Pellet Vent Exhaust Pipe. In a through- the-wall installation you should be mindful of the snowdrift line, as well as dead grass and leaves. We recommend a three foot (3’) minimum vertical rise on the inside or the outside of the dwelling. Never terminate the end vent under a deck, in an alcove, under a window or between two windows. You must use the proper ceiling support flanges and roof flashing supplied by the pipe manufacturer -- follow the pipe manufacturer’s directions and Illustration 1 in this manual. It is important to note that if your vertical runs of pipe are more than fifteen feet (15’) at this point, the pellet vent pipe should be increased to four inches (4”) in diameter. Do not exceed four feet (4’) of pipe on a horizontal run, and do attempt to use the least number of elbows in the flue system. If an offset is used it is better to install a 45-degree elbow whenever possible. Please remember, installing elbows may inhibit your draft by up to 15 per elbow. The flue system should be either masonry or a UL approved pre-manufactured Class A flue system. The flue thimble should be either six inches (6”) or eight inches (8”) and the proper reducer (6” to 3” or 8” to 3”) can be purchased at your local dealer. Connect a three inch (3”) tee with clean-out to the pipe adapter -- seal this with high temperature stove cement, then extend your pipe to the installed reducer at the thimble. If the thimble is in the ceiling, the pipe will go straight up, but if the thimble is in the wall another 90-degree elbow will be required to make the connection. This unit has been designed and tested with this connection, because so many homes are airtight and there is not adequate combustion air available inside the dwelling. Be sure to secure the pipe to the unit with a clamp or aluminum tape. The outside end of the pipe should be covered (screened) to prevent foreign matter from entering the system. Our Outside Air Kit (Part Number PU-OAK) can be used. If the unit is located below ground level, you will need to run the pipe up and then outside the dwelling. NOTE: If the total run of the connection exceeds 6’, if more than 2 elbows are used, or if a basement installation, use 3” metal pipe (and coupler) instead. If the unit is on a combustible surface, you will need to drill matching holes in the floor protection that you choose (see Floor Protection section). Do not disturb the structural integrity of the home, and be sure the unit is permanently electrically grounded to the chassis of your home. Remember that outside combustion air is mandatory, and not to install the unit in a sleeping room of the home. Call Technical Support (800-245-6489) if you have questions about your hook-up or if your unit will not operate. Consumers should check with recalling firms for further details. Extended hours will be in effect until March 15, 2016 from 8 a.m. to 9 p.m. ET Monday through Friday and from 8 a.m. to 2 p.m. on Saturdays. Or, online at www.heatredefined.com and click on Notice located at the top of the page for more information and to register to receive a repair kit. The cast iron pellet stove is about 36 inches high, 24.It has an arched glass door on the front with vents above the door. The Smartstove logo appears on the stove's control panel. The model and serial numbers are located on a black plate on the top right hand corner on the back of the stove. CPSC’s work to ensure the safety of consumer products has contributed to a decline in the rate of deaths and injuries associated with consumer products over the past 40 years. CPSC does not control this external site or its privacy policy and cannot attest to the accuracy of the information it contains. You may wish to review the privacy policy of the external site as its information collection practices may differ from ours. Linking to this external site does not constitute an endorsement of the site or the information it contains by CPSC or any of its employees. Keep children, furnitu re, fixtures and all combustibles away from any heating appliance. SAFETY NOTICE Failure to follow these instructions can result in property damage, bodily injury or even death. For your safety and protection, follow the installation instructions outlined in this manual. Co ntact your local building or fire officials about restrictions and installation inspection requirements (i ncluding permits) in your area. Keep children, furniture, fixtures and all combustibles away from any heating appliance. Page 2 IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT, DO NOT RETURN IT TO THE DEALER. See the “Installation” section of this manual for details pertaining to mobile home installations. Mobile home installation must be in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24. Page 3 TABLE OF CONTENTS. Introduction ? Introduction.4 Specifications ? ? ? ? ? Heating Specifications.5 EPA Compliance.5 Dimensions. 5-6 Installation (Freestanding) ? ? ? ? ? ? ? ? ? ? Installation Overview.7 Clearances to Combustibles.8 Venting Introduction.9 Venting Guidelines.9 Additional Venting Information. Page 4 INTRODUCTION Thank you for purchasing this fine product from England’s Stove Works. England’s Stove Works was started, and is still owned by, a family that believes strongly in a “Do It Yourself” spirit; that’s one reason you found this product at your favorite “Do It Yourself” store. We intentionally design and build our stoves so that any homeowner can maintain their unit with basic tools, and we’re always more than happy to show you how to do the job as easily and as inexpensively as possible. Reduce feed rate. Overfiring will void your warranty. Comply with all minimum clearances to combustibles as specified. Failure to comply may result in a house fire. Tested and approved for wood pellets only. Burning any other fuel will void your warranty. HOT! Do not touch! Severe burns or clothing ignition may result. Glass and other surfaces are hot during operation. CAUTION Keep children away. Page 9 FREESTANDING INSTALLATION Venting Introduction This pellet stove operates on a negative draft system, which pulls combustion air through the burn pot and pushes the exhaust air to the vent pipe and out of the building. This unit must be installed in accordance with the following detailed descriptions of venting techniques; not installing the stove in accordance with the details listed here can result in poor stove performance, property damage, bodily injury or death. Page 10 FREESTANDING INSTALLATION Additional Venting Information. Page 14 FREESTANDING INSTALLATION Approved Venting Method 3: Existing Chimney System For high altitude installations (above 4,000 ft.), the vent pipe should be increased from 3-inch (3”) to four-inch (4”). ? Using an existing masonry or factory built chimney for venting is the only other acceptable method for venting this pellet unit. ? Use Type L or Type PL venting pipe until entering the existing chimney. Page 15 FREESTANDING INSTALLATION Mobile Home Installation. As with all installations involving this unit, the use of outside combustion air is mandatory and MUST be used. Please see the “Outside Air” section on page 16 for more information regarding outside air connections. ? The pellet stove MUST be secured to the floor of the mobile home using lag bolts and the holes provided in the bottom of the pedestal for this purpose. Page 16 OUTSIDE AIR HOOK-UP. The use of outside combustion air is mandatory on the 25-EP. ? The outside air connection pipe protrudes from the lower rear center of the stove; use the included outside air kit to attach your stove to outside combustion air. Instructions and all the parts needed to make the outside air connection to your pellet stove are included with the outside air kit. Page 17 FREESTANDING FLOOR PROTECTION. The 25-EP requires a non-combustible floor protector if the stove is to be installed on a combustible floor. If the floor the stove is be installed on is already non-combustible (i.e. a concrete floor in a basement), no floor protection is needed (although a decorative floor protector can still be used for aesthetic reasons). Parts Included In Insert Conversion Kit o Surround Top Panel o Surround Left Panel o Surround Right Panel o Left Side Panel o Right Side Panel o Rear Hopper Cover Plate Assembly Instructions 1. Page 19 FIREPLACE INSERT INSTALLATION Insert Assembly Continued 6. Use the included self-drilling sheet metal screws to screw the Rear Hopper Cover Plate to the hopper of the stove while carefully holding the lid in place to be certain it remains centered on the stove. Page 20 FIREPLACE INSERT INSTALLATION Clearances to Combustibles Unit Clearances to Combustibles Clearance to Mantle (A) 16 IN. 406.4 MM. ? ? ? ? ? ? ? ? ? ? Side (B) 6 IN. 152.4 MM. WARNING INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER. Supervise children in the same room as this appliance. Page 21 FIREPLACE INSERT INSTALLATION Venting Introduction This pellet stove operates on a negative draft system, which pulls combustion air through the burn pot and pushes the exhaust air to the vent pipe and out of the building. Page 22 FIREPLACE INSERT INSTALLATION Additional Venting Information. The installation of a fireplace insert can be challenging and requires knowledge of chimney systems that the average homeowner does not have. Due to this, England’s Stove Works highly recommends having this insert professionally installed. ? However, if this installation is performed by the homeowner, follow the guidelines listed below. Do not mix and match components from different pipe manufacturers when assembling your venting system (i.e. Page 23 FIREPLACE INSERT INSTALLATION Approved Venting Method: Full Chimney Relining. Use a chimney liner system specifically designed for pellet stove use; follow the guidelines in the previous section regarding appropriate liner diameter. ? Use the tee supplied by the liner manufacturer to connect the exhaust outlet of the stove to the chimney lining system. ? Seal the throat of the fireplace with a sheet metal block-off plate screwed to the walls of the fireplace. Page 24 OUTSIDE AIR HOOK-UP. The use of outside combustion air is mandatory on the 25-EP Insert. ? The outside air connection pipe protrudes from the lower rear center of the stove; use the included outside air kit to attach your stove to outside combustion air. Page 25 FLOOR PROTECTION. The 25-EPI requires a non-combustible hearth if the current hearth of the fireplace does not extend the required distance from the front of stove. Follow the diagram below to determine if the current fireplace hearth is sufficient. ? If the current fireplace hearth is not large enough to accommodate this insert, a hearth extension pad (which is designed and sold specifically for this purpose) can be used. A hearth extension pad should be U.L. Page 26 FREESTANDING AND INSERT - DAILY OPERATION Getting Started. Check to see that the hopper is clean and free from foreign materials. Be sure to connect this unit to a working outlet; we recommend using a surge protector to help protect the electronic components from damage. ? BEFORE your first fire, dry run your unit (no pellet fuel in the hopper) for twenty minutes; pressing the “ON” button with the unit plugged in will initiate the dry run. Page 27 ? The 25-EP will perform equally well using softwood and hardwood pellets, and although the ash may differ slightly in appearance or texture, both types of pellets will burn cleanly and efficiently in this stove. ? The 25-EP is equipped with an automatic pellet ignition system; the only user input required to light the stove is a simple press of the “On” button. ? Shortly after pressing the “On” button, the letters “S U” will appear in the heat range and blower speed windows of the control board.