Error message

Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home1/dezafrac/public_html/ninethreefox/includes/common.inc).

7

elk m1 gold manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:elk m1 gold manual.pdf
Size: 3216 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 7 May 2019, 18:54 PM
Rating: 4.6/5 from 839 votes.

Status: AVAILABLE

Last checked: 16 Minutes ago!

In order to read or download elk m1 gold manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

elk m1 gold manualThis Manual pertains to both the ELK-M1G and the ELK-M1. Page 2 IntroductionHowever, it. Page 3 Table of Contents. Specifications, Features, and Benefits. 5. Section 1 - Installation. Page 4 ELK-M1Page 7 DemarkThe first step in any multi-zone security system installation is. Page 9: 1.4 Control Wiring Keypad Mounting and Wiring. Ideal keypad height is 50-58 inches above the floor. Select a location with an ambient temperature. Page 10 Two-Wire Smoke Zones (Zone 16). To enable the use of two-wire smoke detectors on Zone 16, move Jumper JP1 (located. Page 11 AC Failure, Low Battery, and Automatic Low Voltage Shutdown. During an AC power failure the battery automatically takes over and. Page 12: Data Bus E.O.L. Termination - VERY IMPORTANT! Data Bus E.O.L. Termination - VERY IMPORTANT! Unlike many controls, the M1 features a true RS-485 “differential” data bus operating. Page 13 The ideal way to connect multiple home run cables is with an ELK-M1DBH Data Bus Hub. It accepts CAT5 or. Page 14: 2.4 Installer Program Code and Authorities Section 2 - Operating the SystemFor best operation during bench testing, all zones should be terminated with. Page 15: 2.5 Keypad Overview 2.5 Keypad Overview. Ready Light - This light is ON when all burglar zones are secure and the system is. Page 16: Keypad Menus 123456789012345678901234567890The siren(s). Page 18 123456789012345678901234567890Then press the up or down arrow. Page 19 123456789012345678901234567890Page 20: Multi-area (Partition) Operation Multi-area (Partition) OperationThe Security functionality of the M1 Control can be programmed either from. Page 22: 3.6 Entering Installer Level Programming 3.5 Communicator Setup Checklist. The Communicator (Dialer) in the M1 can dial up to 4 telephone numbers in addition to. Page 23 ELK-M1 and ELK-M1G QUICK REFERENCE - MENU PROGRAMMINGPage 24: Menu 01 - Bus Module Enrollment 12345678901234567890123456789012123Press UP or.http://www.santaclaradistribuidora.com.br/admin/fckeditor/uploads/dell-dimension-9200-service-manual-pdf.xml

    Tags:
  • elk m1 gold manual, elk m1 installation manual, elk m1 gold user manual, elk m1 gold installation manual, elk m1 gold programming manual, elk m1 gold manual, elk m1 gold manual, elk m1 gold manual pdf, elk m1 gold manual, elk m1 gold manual pdf, elk m1 gold user manual.

Page 25: Menu 02 - User Code Options 12345678901234567890123456789012123Press UP or. Page 26: Menu 03 - Area Definitions 12345678901234567890123456789012123Press UP or DOWN. Page 27 Menu 03 - Area Definitions (continued)Press UP or DOWN. Page 29 Menu 04 - Keypad Definitions (continued)Page 30: Menu 05 - Zone Definitions 12345678901234567890123456789012123Press UP or DOWN. Page 31 Menu 05 - Zone Definitions (continued)Page 32 Menu 05 - Zone Definitions (continued). Zone DefinitionsPage 33: Menu 06 - Alarm Duration Timers 12345678901234567890123456789012123Global Sys Definitions Description of OptionPage 36 Menu 07 - Global System Definitions (continued). Global Sys Definitions Description of OptionPage 37 Menu 07 - Global System Definitions (continued). Global Sys Def Description of OptionPress UP or. Page 39 Menu 08 Telephone Account Setup (continued). Telephone Acct SetupPage 40: Menu 09 - Area Reporting Codes 12345678901234567890123456789012123Press UP or. Page 41 Menu 09 - Area Reporting Codes (continued)Page 42: Menu 10 - Zone Reporting Codes 12345678901234567890123456789012123Press UP or. Page 43: Menu 11 - Keypad F-Key Reporting Codes 12345678901234567890123456789012123Sys Rpt Code OptionsPage 46: Menu 13 - User Report Codes Menu 13 - User Report CodesPress UP or DOWN. Page 48 1234567890123456789012345678901212345During the connect and disconnect process RP performs an automatic check of the data stored in. Page 51: 4.3 Automation Rules and Attributes 4.3 Automation Rules and Attributes. The ELK-M1, together with the RP Automation Programming software offers powerful, easy to setup and. Page 52 LIGHTING - The M1 can control up to 256 Light (or appliance) devices. Each is assigned to one of 256. Page 53 VOICE - This section is used to setup and customize many of the 6 word phrases that can be spoken.Rules consist of. Page 56 AND - The second and optional element of a rule is a qualifier. Rules can have one or more.http://micronetglobal.com/userfiles/dell-dimension-b110-manual.xml Page 57 Examples of Rules - Shown below are a series of rules that should help illustrate the power and results that. Page 58: Appendix A - Event Codes Appendix A - Event Codes. Page 59 Appendix A - Event Codes (cont.). Event Description Reset Event Description Reset Event Description Reset. There are two methods of entry. Automation Menu continuedWord or Phrase Word or Phrase Word or Phrase Word or. Page 63 Appendix C - Voice Message Vocabulary (cont.). Word or Phrase Word or Phrase Word or Phrase Word or Phrase. Using a Two Way Interface board (ELK-M1TWI), the M1 accommodates up to. Page 65: Appendix E - SIA CP-01 Compliance Appendix E - SIA CP-01 CompliancePage 66: Appendix F - Regulatory Agency Statements Appendix F - Regulatory Agency Statements. The ELK-M1 complies with Part 68 of the FCC rules. On the front nameplate. M1 Installation and Programming Manual Page 67Page 70 M1 LIMITED WARRANTY. The ELK-M1 and its associated component products are warranted by Elk Products, Inc. (“Manufacturer”) against defects. Page 71: Index Index. A I Rules 55. Alarm Cutoff Timers 33 Installation and. Page 72 www.elkproducts.com. It fits into a single gang electrical box and utilizes any standard decorator style faceplate. The low cost and small footprint of the M1 KPAS Arming Station makes it ideal for use as an alternative to the larger and more costly LCD keypads. It is particularly well suited for partitioned jobs such as an office, workshop, garage, etc., where full functionality is not necessarily required. The 12 button keypad is backlighted with blue LED s and has quick arm keys for Exit (Away) and Stay. Access to six (6) Programmable Functions. Built-in Piezo Mini Sounder. Quick arm keys for Exit and Stay. Color: White ! Operating Voltage: 13.8 VDC ! Current Draw: Less than 30 mA with min. In some cases a special dual voltage box or divider partition (separator) may be successfully used. Visit your local home center or electrical supply company for availability.http://eco-region31.ru/boss-fs-6-manual-0 Elk specifically warns against improper use, particularly unauthorized installation or servicing in conjunction with high voltage circuits except by licensed and qualified high voltage personnel. Elk is not responsible for damages or harmful consequences. Always consult the local AHJ and follow state and local regulations. In some cases the best solution is to install the M1 KPAS into a separate and dedicated single gang box.Thank you, for helping us keep this platform clean. The editors will have a look at it as soon as possible. Please update your browser or use Internet Explorer 11 or the current version of Microsoft Edge, Firefox, Chrome or Safari. Thank you! For the very latest downloadable version of this manual please go to our website:Hildebran, NC 28637General Installation and Setup. 4Data Bus Enrollment. Data Bus Address Switches. Operation. 7. List of Elk 6000 Series Wireless Sensors. 8. Quick Step Enrollment for Elk 6000 Series Sensors. 9. Detailed Keypad Programming. 10. Appendix A - Data Bus Selection Tables. 12. Appendix B - Examples of Zone Configurations. 14. Appendix C - Installing Multiple Redundant Receivers. 15. Appendix D - Updating Firmware in the ELK-M1XRF. 15Operation is subject to the following two conditions:Part NumberM1 Two-Way Receiver. Wireless Slim-Line Door and Window Sensor. FCC ID NumberM1XRFTW Installation ManualRefer to the list of available transmitters in this manual. Including this new Elk Two-Way Receiver, Elk now produces three (3) different models of wireless receivers for the M1 Control. One is for Elk sensors (M1XRFTW), one is for GE sensors (M1XRF2G), and one is for Honeywell sensors (M1XRF2H). Regardless of the receiver model, they each attach directly to the M1 via the four (4) wire Keypad Data Bus.http://cydistribution.com/images/92-honda-prelude-owners-manual.pdf And they enrollThe benefits of operating from the data bus are: 1) Receiver(s) do not have to be installedUtilizing multiple receivers it is possible to cover hundreds if notA strong point of the Elk Receivers is that all transmitter serial numbers and setup information is stored in the control panelThere are two advantages of this: 1) Sensors need only be enrolled one time, yet they can. This is especially great for coverage of portable. Keychain (FOB) Remotes. 2) Should a receiver ever become damaged or need replacement it will not be necessary to reenroll the transmitters. Simply replace the receiver and perform a data bus enrollment of the receiver to the control panel.While this isM1XRFTW Installation Manual. Page 3Antenna. JP1 Bus. Terminating. JumperAddress. SwitchesConnections. NOTE: Jumper JP1makes it convenient to terminate the RS-485 Data Bus if this is the last installed device.Mount at least 10 feetElectrical noise can and may reduce theFor increased signal coverage or redundancy additional M1XRF Receivers (up to 11 max.) may beSee Appendix C.NOTE: Refer to the M1 Installation Manual and the M1DBH information in this manual about proper connections of data bus devices with multiple homerun cables.There is no external antenna required.STATUS (Data Bus Status) - Multiple conditions exist for this LED:This should only occur if you are field updating the unit. It will not be operational until application firmware has been flashed into the unit using ElkRP. LEARNED RF - This LED will momentarily turn on when the M1XRF receives a valid transmitter and is in the process ofAs soon as the packet is acknowledged by the M1 ControllerALL RF - This LED blinks whenever ANY Elk RF transmitter is heard or detected. DATA BUS ACTIVE - This LED blinks near continuously and indicated activity on the M1 Data Bus. Page 4. M1XRFTW Installation ManualEvery device on the M1 RS-485 4-wire data bus must have a valid address setting (from 1 to 15) within it's device type. TYPE 1 is for Keypads, TYPE 2 is for Hardwire and Wireless Input expanders, TYPE 3 is for Output expanders, TYPE 4 isThe device types allow address numbers to be re-used in each different device type. There are 4Set the switches to the desired data busSee important information beforeExpander(s) installed on the same control. These conflicts can be avoided with proper understanding ofThe important point to remember isM1XIN Expanders: A single ELK-M1XIN Hardwired Zone Expander (M1XIN) provides 16 hardwired zones. The data busSee Table 1-1. If additional M1XINs are installed,Everything works fine as long as there are NO DUPLICATE addresses. M1XRF Receivers: The differences between a ELK-M1XRF Wireless Receiver and a ELK-M1XIN Zone Expander are:These are assigned in groups of 16 at a time. One stipulation is that to have 144 total wireless zones the first group of 16 must begin at zone 17 and the balance of theIf any hardwired zone expanders are enrolled in the range ofType 2 device. NOTE: The data bus address of an M1XRF Receiver does not inherently set starting wireless zone number. Even so. Elk strongly encourages Installers to set the data bus address of the first M1XRF Receiver to the starting zone ID asOther important considerations when installing an M1XRF:M1XIN Hardwired Zone Expander, or vs. versa.See Appendix C.Put another way, zones 161 through 208Example: You decide to create 64 contiguous wireless zones.That would mean that zones 17 to 31, 32 to 48, 49 to 64, and 65 to 80 are going to be wirelessAs a result, addresses 3,4, and 5. ARE NOT AVAILABLE for use by M1XIN Expanders because the wireless zones are overlapping these addresses. NOTE: Consider whether the system may ever required more wireless or hardwired zones. If the answer is yes itM1XRFTW Installation Manual. Page 5Data Bus Starting and Ending. Address. Zone NumbersZones 33 - 48. Zones 49 - 64. Zones 65 - 80. Zones 81 - 96. Zones 97 - 112. Zones 113 - 128. Zones 129 - 144. Zones 145 - 160. Zones 161 - 176. Zones 177 - 192. Zones 193 - 208M1XRF Wireless Receivers. Switch SettingsOn. Off. On. Switch Settings. Data Bus Suggested WirelessZone 33. Zone 49. Zone 65. Zone 81. Zone 97. Zone 113. Zone 129. Zone 145Table 1-1. Other Jumper. Settings. JP1 - Used toOhm resistor forRS-485 Data Bus. See Data busTable 1-2. Data Bus Enrollment. Once the address is set and the M1XRF is powered up it will be necessary to manually ENROLL the device so that the M1. Control knows it is present.The Installer Program Code (PIN) must be entered to access 12345678901234567890123456M1XRFTW Installation ManualElk's Two-Way technology is vastly superior to traditional one-way wireless. Each transmission from an Elk sensor isPositive acknowledgement of a transmission results in the sensorIn a rare case where the transmission is not acknowledged by theEach sensor also monitors and adjusts its ideal RF power,Confidence of signal strength at the time of installation another unique feature of the Elk Two-Way technology. As longRequirements for Programming the Receiver and Enrolling Transmitters. The Receiver and wireless transmitters may be programmed using either the M1 Keypad Installer Programming or the ElkRP. Remote Programming software. The following pages document the options and steps for programming from the keypad. M1XRFTW Installation Manual. Page 7Wireless Devices may be enrolled into M1 from the Keypad Installer Level Programming or from ElkRP. Keypad Installer Programming utilizes Menu 14 and the LRN (Learn) process. Note: The process may vary between some sensors. Follow theElkRP Remote Programming involves typing in the TXID (serial number of the sensor) along with selecting the particular attributes. Image. Part Number(s). Elk6010 Wireless Keychain. Remote (FOB). For M1 Keypad Installer Programming use Menu 14 and sub-menu 3. Then follow the published. Use Method 3 to Enroll Sensor. Be sure to program the Supervision Type (sub-menu 2, option 2) as “O”While the button event function isAfter a Keychain Remote has been enrolled it will be necessary to program its Zone Definition (Menu 05) as KEYFOB. Use Method 2 to Enroll Sensor. Elk6020 Wireless Slim-Line. Door and Window Sensor. Use Method 1 to Enroll Sensor. Elk6021 Wireless Mini. Elk6022 Wireless UniversalClose Circuit Contacts. ELK6030 Two-Way PIR. Motion Detector. ELK6050 Smoke Detector. Two-Way with Internal Sounder. Use Enroll Method 2. Use Enroll Method 4. Single Button Panic Xmtr. Use Enroll Method 3 NOTE: Program Zone Def. as KEYFOB. The single button responds as KEY 4 and MUST be assigned aRefer to WZnxxx 02 (Supervision Type). Type in Xmtr Decimal IDThis prevents nuisance missing transmitter troubles. Refer to WZnxxx 02 (Supervision Type). Holdup Switch Xmtr. Type in the Xmtr Decimal IDWireless Outdoor Motion Sensor. Xmtr. Shock Sensor. Shock Processor Xmtr. Sw. Glassbreak XmtrHeat 'Rate Of Rise' Xmtr. Page 8. Use Method 2B to Enroll Sensor. This Sensor has 1 built-in Reed Switch PLUS 2 Aux. “Closed Circuit” Zones. This sensor must be enrolled as a separate wireless zone for each Zone input to be used. The same TXID will be enrolled into each of the 3 wireless zones. To assign which Input represents which wireless zoneThe Reed switch is always Loop 2. The aux. input IN1 is Loop 1 and the aux.Use Enroll Method 2B NOTE: This Xmtr has 3 inputs and can be enrolled into 3 zones.The 1st zone could be Loop 1, the 2nd Loop 2, and the 3rd Loop 3. See sensor instructions. RepeatUse Enroll Method 2. Temperature Sensor OR Flood Detector. M1XRFTW Installation ManualEnrolling from M1 Keypad Installer ProgrammingThis establishes the first (starting) wireless zone.A blank location will display TransmitrToLrn while any existingAfter each Sensor is successfully enrolled the M1 Rapid-Enroll feature will advance toThe Rapid-Enroll may be exited by pressing the ELK key.The 6000 series sensorsNOTE: If battery is already inserted, remove it and wait 5 seconds before re-inserting. If enrollment is successful the M1 Keypad will emit a ding-dong and briefly display the 6 digit TXID code which is labeled on the Sensor. If enrollment FAILS the TXID will not display. If that happens remove the battery, wait 5 seconds, then re-insert. If the M1 Lrn (Enroll) functionZone 1 - Enroll the sensor and first zone by inserting the Battery into the Sensor while the M1 Lrn mode is active. Zone 2 - Upon successful enrollment of the sensor and zone 1 REMOVE the Battery and wait 5 seconds. Then, with M1 still waiting for theZone 3 - Upon successful enrollment of zone 2 REMOVE the Battery again and wait 5 seconds. Then, with M1 still waiting for the next sensor,With each successful enrollment the Keypad should emit a ding-dong and briefly display the 6-digit TXID code which is labeled on the Sensor.If enrollment is successful the M1 Keypad will emit a ding-dong and briefly display the 6 digit TXID codeIf enrollment FAILS the TXID will not be displayed. Try repeating the PRESS and HOLD on the button. If the M1 Lrn (Enroll) function has endedM1 Rapid-Enroll Feature - The M1 Rapid-Enroll feature advances to the next zone in sequence and waits for another sensor to be enrolledAfter enrollment the Loop number must be properly programmed for each wireless zone. ScrollThe screen will display a 9 digit number (the TXID in decimal) followed. For the majority of sensors which have only a single zone (input) the Loop. For all other sensors follow the specific instructions supplied with the sensor. Enrolling from ElkRP SoftwareElkRP requires zones (including wireless) toWireless Zones can exist from Zone 17 (Group 2) up to Zone 160 (Group 10). Click on New Wireless ZonesRepeat if additional wireless groups are required. NOTE: If a large number of wireless zones are expected, try to AVOID conflict with existing or future Hardwired Zones in theLoop 2 is for the built-in reed, Loop 1 is for external IN1, and Loop 3 is for external IN3.Reminder: Sensors that offer multiple zone inputs (i.e. 6022) must be enrolled again for each input that will be used. WeThe TXID number will be the same. Page 9From the keypad enter the Installer Level Programming mode. Navigate to the Wireless Setup - Menu 14 and press the RIGHT arrow key to select.Enroll, and 4-Keyfob Event Definitions. Use the UP or DOWN arrow keys to locate the desiredSetup. Wireless SubmenuReceiver Options. Reg. SupervisionThis submenu is for Receiver options. To select this menu press the RIGHT arrow key, orThe range is 001 to 255 hours. If a Type 1NOTE: A value less than 4 hours is NOT RECOMMENDED!The range is 001 to 255 hours. If a Type 2NOTE: A value less than 4 hours is NOT RECOMMENDED! This submenu is for specific transmitter options. Some options are not applicable to thisDown arrow keys to scroll the submenus.Transmitter Opt rWireless Zone. Use the UP and DOWN arrow keys to locate a particular wireless transmitter. Press the. RIGHT arrow key to select and program the displayed transmitter. Enable Transmitr. Displays whether a transmitter is enabled or disabled. This option CANNOT be used to add aSupervision Type. Supervision type sets the expected check-in interval of a sensor. KeyChain Remotes (Fobs). Fire Sensors should have. See receiver selections R02 and R03 for supervisionFactory default setting is 1 (Normal Supervision).For KeyChain Remotes setting this option to. Yes converts buttons 1,2,3,4 to be instead buttons 5,6,7,8. Default is No. See list ofDefault is No. See list of compatible Transmitters to determine which (if any). Enable Option 1. Enable Option 2Used to program the User ID which will be logged when a Keychain Remote assigned to thisValid range is 001 to 255. Numbers 001 to 199 mirror keypad. Not used. If set to Yes the zone is auto-restored to normal in 8 seconds with no restoralWZn017 shown as an example only!M1XRFTW Installation ManualWirelessTransmtrThis submenu is used for manually enrolling transmitters (Sensors). To select this menuSelect the zone to enroll a new transmitter by entering the three (3) digit zone number OR byNOTE: If a transmitter isOtherwise, it will display. Press the RIGHT arrow key to select and program that zone.TransmiterButtonUNLESS a transmitter is already enrolled (see below). Proceed to the transmitter and executeIf successful the. Displays the zone number and ID of the enrolled transmitter. NOTE: After a new transmitter isDELETING A WIRELESS TRANSMITTER - To delete or replace an existing transmitterEvent Definition. The left numberPress the RIGHT arrow key to move cursor. But for any sensorLoop number must match the input being used for this zone. Each button can be assigned one of six (6) separate operations as explained below. ToPress the UP or DOWN arrow keys to select a key (button) 1 to 8. Some keys (buttons) mayThe definition or operation is programmed using aManual. The range is 0000 to 0030 See M1 Installer Manual, Appendix A, Event Codes. By factory default the M1 programming is assigned to the following keyfob buttons withM1 Default Value. System Status. Operation. KeyMomAway (Arm the Control). KeyMomDisarm (Disarm the Control). Center Key on Elk6010 KeyChain Remote is not programmable. It is permanently set toM1XRFTW Installation Manual. Page 11These tables are intended to help visualize how the Wireless Zones and Hardwired Zones share the data bus address assignments. They should help with the setting of a starting zone ID and data bus address(s) to obtain the total and best mix of wireless andNOTE: The total (max.) number of wireless zones is decreased by 16 zones for any hardwired expanders installed orThis is because only zones 17 through 160 can be used for wireless. This narrow down which table to concentrate on.The wireless starting zone ID is critical if you want all wireless zones to beThe following are some suggested guidelines:Follow the row of cells acrossHowever, any of these addresses may also be usedRedundant Receivers provide additional range and coverage for extremely large or difficult buildings. See. Appendix C regarding Redundant Receivers. NOTE: An M1XRF installed for redundancy does not increase the number of wireless zones, it only increases. No RF Zones Here. Total. Wireless. ZonesData bus. Addr 2. Zn 17-32Addr 3. Data Bus. Addr 4. Addr 5. Addr 6. Addr 7. Addr 8. Addr 9. Addr 10. Addr 11. Addr 12. Addr 13. Zn 33 - 48. Zn 49 - 64. Zn 65 - 80. Zn 81 - 96. Zn 97 - 112. Zn 113-128. Zn 129-144. Zn 145-160. Zn 161-176. Zn 177-192. Zn 193-208. H or RRF. Starting. Data bus. Addr 3. Zn 33-48. ZonesZn 17 -32H or RRF. H or RRFWireless. ZonesData Bus. Zn 17 -32. Zn 33 - 48H or RRF. Zn 49 - 64M1XRFTW Installation ManualNo RF Zones Here. Zn 49 - 64H or RRF. Zn 65 - 80Addr 6. H or. H orStarting. Zn 65 - 80H or RRF. Zn 81 - 96H or RRF. H or RRFStarting. Zn 97 - 112H or. Zn 97 - 112H or RRF. Zn 113-128H or RRF. Zn 129-144Total. Zn 129-144H or RRF. Zn 145-160Addr 11. Page 13Example A. All 208 Zones as Hardwired. Example CPLUS 2 Redundant Receivers. Example BInputs on. Main Panel. ZonesAddr x. Inputs on. ZonesAddr 2Addr 2Addr 2Addr 3Addr 3. Upon successful enrollment the Keypad will chime and briefly display the 6 digit TXID code of the Sensor.If that happens then remove the battery, wait 5 seconds, then re-insert.C. To enroll the next Zone (marked LP1) on this sensor REMOVE the Battery and wait 5 seconds. Then re-insert Battery intoA. PRESS and HOLD button 1 or button 2 while M1 is displaying Push Transmitter Button. B. Upon successful enrollment the Keypad will chime and briefly display the 6 digit TXID code of the Sensor.If that happens then remove the battery, wait 5 seconds, then re-insert. NOTE: If the M1 Lrn (Enroll) function times out or is manually exited then It may be necessary to restart from Step 1Press the right arrow and move cursor over toEnrolling Sensors from the ElkRP SoftwareIn the folders column rightSelect Group 2. NOTE: The first M1XRFTW must be enrolled at dataIt a hardwired zone expander is occupying address 2 it will have to be relocated to another addressIf a large quantity of wireless zones is expected, avoid enrollingThis will allow for the maximum of 144 wireless zones.Then selectZones definitions may be assigned before or after sensor enrollment. B. Place a check mark in the Enabled box. F. Click Save. Repeat the entire step 4 for each additional Wireless Sensor. IMPORTANT! For sensors with multiple zone inputs the enrollment must be repeated for each additional Zone Input and the TXID will beM1XRFTWM Installation Manual. Page 9From the keypad enter the Installer Level Programming mode. Navigate to the Wireless Setup - Menu 14 and press the RIGHT arrow key to select.Setup. There are four (4) wireless setup submenus: 1-Receiver (Transceiver) Options, 2-Xmitter. Options, 3-Xmitter Enroll, and 4-Keyfob Event Definitions. Use the UP or DOWN arrow keys toWireless Submenu Receiver Options. Description. This submenu is for Receiver (Transceiver) options. To select this menu press the RIGHT arrowReg. Supervision. Sets the expiration timeout value for supervision of zones assigned as Supervisory Type 1 (NonFire Zones). The range is 001 to 255 hours and the default is 024 hours. If a Type 1 sensorThe Type is assigned to eachFire Supervision. Sets the expiration timeout value for supervision of zones assigned as Supervisory Type 3 (Fire. Zones). The range is 001 to 255 and the default is 004 hours. Should a Type 3 sensor fail toUL Wireless-Jam. For UL listed installations with the Elk-XRFTW Transceiver this option should be enabled. ThisTransmitter Opt r. WZn017:Sel bPrg r. Wireless Zone. Enable Transmitr. Supervision Type. Enable Option 1. Enable Option 2. This submenu is for specific transmitter (sensor) options. To select this menu press the RIGHTUse the UP and DOWN arrow keys to locate a particular wireless transmitter. Press the RIGHTThis option CANNOT be used to add a newThis sets the expected check-in (supervision) interval of a sensor. Burglar (non-fire) sensors. See receiver selections R02 and R03 for supervision time values. ValidThis is relevant to a few select sensors. Factory default is No. See the List of Elk 6000. Series Wireless Sensors to determine which transmitters use this option. This is relevant to a few select sensors. Keyfob User ID. This location allows a number to be assigned as the User ID that will appear in the M1 event. Valid range is 001 to 255. NOTE. Standard M1 User codes are 001 to 199. PIR Auto Restore. This option (PIR Auto Restore) is not currently used by the M1XRFTW. WZn017 shown as an example only! Page 10. M1XRFTWM Installation ManualWirelessTransmtrTransmitrToLrn r. This submenu is used to manually enroll transmitters (sensors). To select this menu press the. RIGHT arrow key, or press the Up or Down arrow keys to scroll submenus. Select the zone for the new transmitter (sensor) by entering the three (3) digit zone number ORNOTE: If a transmitterOtherwise, it will display. Press the RIGHT arrow key to select and program the zone.TransmiterButtonEnrolled ABCDE1If successful the keypad will chime and M1 will. The TXID of the newly enrolled transmitter (sensor) will momentarily display. Rapid Enroll willPress the ELK key twice to exit the enrollment after all new sensors have been enrolled.Event Definition. M1XRFTWM Installation ManualPress the RIGHT arrow to move the cursor. Each button can be assigned one of six (6) separate operations as explained below. ToPress the UP or DOWN arrow keys to select a key (button) 1 to 8. Some models may notThe event or operation for each button is set by a fourThe range of event codes is 0000 to 0030 See M1 Installer Manual. Appendix A, Event Codes. Key1 - Lock. Key2 - Unlock. Key3 - i Status Inquiry. Key4 - Red Triangle. NOTE 1: Key (button) 3 on a 6010 Keychain Remote ALWAYS performs a system status Inquiry when pressed momentarily. This same key may be pressed and held for four (4) seconds toFactory default is 0000 (do nothing). NOTE 2: Key (button) 4 on a 6010 Keychain Remote REQUIRES a press and hold for two (2)This can be any event, however the most common use is for emergency panic (Police Panic event 0023 or 0024). FactoryWhile it is not possible toOption 1 from Menu 14, sub-menu 2:Xmit Transmitter Opt. Page 11This table should help visualize how the Wireless Zones and Hardwired Zones share the data bus address assignments. Please note that No. Wireless Zones Are Allowed Above Zone 160. The left column indicates the totalAnd be sure to alsoNOTE: The total (max.) number of wireless zones will be decreased by 16 zones for any hardwired expanders installed and enrolledThe reason is that only zones 17 to 160 can be used for wireless zones, and data busIt is strongly recommended that all wireless zones be sequential, with no hardwired zones interspersed between them. The following are suggested guidelines:Follow this row acrossThe top of this column shows the data bus address where an M1XIN Hardwired Zone.