electronics line summit 3208 installation manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:electronics line summit 3208 installation manual.pdf
Size: 1496 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 25 May 2019, 13:34 PM
Rating: 4.6/5 from 644 votes.
Status: AVAILABLE
Last checked: 13 Minutes ago!
In order to read or download electronics line summit 3208 installation manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
electronics line summit 3208 installation manualElectronics Line We strongly urge you to read through this manual, in its entirety, before beginning the installation process so that you can best understand all that this security system has to offer. This manual is not intended for end user use. End users are encouraged to read the Summit 3208GLD User Manual that accompanies the system. All data is subject to change without prior notice. -3- Both hardwire and wireless zone expanders are available. You can precisely configure each zone to suit a wide variety of applications. Zone Descriptors Each zone can be assigned an individual zone descriptor. You can choose these from the standard zone descriptor library or from one of the four custom zone descriptors that are programmable to suit the installation. Zone Type One of fifteen zone types can be defined for each zone. The zone type dictates the nature of a specific zone s operation. The following is an explanation of each zone type. Perimeter and Interior Zones Different methods of arming the system rely on the definition of zones as perimeter or interior. For example, when the user wishes to remain on the premises, STAY arming secures only perimeter zones allowing free movement within the protected area. Perimeter and Interior zones can be defined as Normal, Primary, Secondary or Conditional. Normal Zone: A normal zone generates an alarm when opened. Primary and Secondary Zones: Primary zones never actually generate an alarm; they are always used in conjunction with secondary zones. A secondary zone will generate an alarm only if opened during the entry delay of a primary zone. These zones are intended for use in situations where the primary zone is an unprotected area that is crossed by an intruder to reach the area protected by the secondary zone. This rules out the need to compromise the sensitivity of the devices installed in the secondary zone to achieve maximum false alarm immunity.http://1worldlanguage.com/1worldlanguage/userfiles/defender-puma-workshop-manual-download.xml
- Tags:
- electronics line summit 3208 manual, electronics line summit 3208 installation manual, electronics line summit 3208 installation manual number, electronics line summit 3208 installation manual pdf, electronics line summit 3208 installation manual instructions, electronics line summit 3208 installation manual transmission.
Conditional Zone: Conditional zones do not generate an alarm when opened during the entry delay - otherwise, an alarm is generated instantly. These zones can be used for detectors protecting the area in which a keypad has been installed or the area crossed in order to reach the keypad. 24hr zones 24hr zones are always operational regardless of system status and will generate an instant alarm when opened. Fire and Verified Fire Zones: Fire zones are designed for use with smoke detectors. A fire zone will generate an instant alarm when opened. Verified fire zones will not sound an alarm and will not send a message to the central station unless a second detection has been made within a minute of the first. The Summit 3208GLD control panel can be programmed to enable automatic or manual power reset for latching smoke detectors (see address 495). Tamper: This zone type is used with tamper switches and is designed to prevent unauthorized opening of the metal housing. Common Zone A common zone belongs to all systems. An alarm will only be generated from a common zone if all the subsystems are armed. Common zones are generally used in partitioned systems where a corridor is shared by more than one protected area. Note: When arming, if the only zones open are common zones, the system is still Ready. Keyswitch zones Two zone types offering different operational modes are available for use with a momentary keyswitch. Swinger Zones Swinger zones limit the amount of alarms that can be sent from a specific zone within a predetermined time period. This feature is designed for use with zones that are highly prone to false alarms. The swinger parameters are programmed at address 388 and at the second address for each specific zone. -5- The following section describes how certain elements of the system are affected by system partitioning. Zones Each zone can be assigned to a one of the four sub-systems.http://atcotourismtravel.com/userfiles/defender-rave-manual-download.xml A common zone is assigned to all subsystems and will only be armed in the event that all systems are armed. User Codes User codes are assigned to any sub-system or to the entire system during user code programming. For more information on the programming of user codes refer to page 23. Keypad Display The keypad can display either the entire system or a specific sub-system. A user code assigned to a specific sub-system only arms that sub-system. If the user code is assigned to all systems, the panel asks which system to arm. Entering System 5 arms all the sub-systems that are ready. There is no way of disarming all sub-systems simultaneously; sub-systems must be separately disarmed. To disarm a sub-system, the user code entered must be assigned to either that sub-system or to all systems. All arming methods are available for each sub-system. 1.4: Telephone Dialer You can program up to four different telephone numbers into the system, employing either pulse or DTMF tone dialing methods. Up to 16 digits can be programmed for each telephone number. The Summit 3208GLD supports several communication protocols including Contact ID and various pulse protocols, enabling communication with most popular central station receivers. In some cases the central station handles events reported per zone and in others per event. Event codes can comprise of either one or two digits and can include additional information such as the user number in opening and closing messages or zone ID in event oriented zone messages. These codes are usually assigned by the central station consult the central station operator for a listing of the different event codes. Follow-me Using the Follow-me feature, the panel can notify the user that the system has undergone certain events by sounding a sequence of tones over the telephone. If this acknowledgement is not received within the oneminute time window opened the moment the panel starts dialing, the control panel redials.http://afreecountry.com/?q=node/4365 The number of dialing attempts made depends on the value programmed at address 197. When the panel calls the Follow-Me number, the Voice Module plays back the appropriate message to identify which type of event has occurred. Telephone Line Supervision (firmware dependent) Approximately 20 seconds after the telephone line is cut, all keypads sound a trouble beep and the message Telephone Comm. Failure appears on LCD keypads. -6- You can do this from either a remote location or on-site using the Off-hook communication option. The software provides a comprehensive interface to the Summit 3208GLD control panel facilitating and cutting down the time taken in programming the system. A number of programmable options, relating to when and how RP communication is established, are available at address 496. The tollsaver feature, RP Callback, makes remote programming more costeffective and increases the level of security. Using this feature, the Remote Programmer establishes a connection with the panel. The panel recognizes the passcode, hangs up and calls the number programmed at addresses within 60 seconds. Answering Machine Override Answering machine override enables the control panel to distinguish between regular incoming calls and a communication attempt by the RP (remote programmer) software. An RP call is identified by the control panel as a sequence of two calls within a 30-second time window. 1. The control panel does not answer the first incoming call. 2. The control panel opens a 30-second time window from the moment the telephone stops ringing. 3. The control panel answers after the number of rings defined at address 496 and RP communication is established. 1.6: Other Features Opening and Closing Windows This feature helps cut down the amount of opening and closing reports sent to the central station. The opening and closing windows are programmable windows of time, during which the user usually arms or disarms the system.http://iluvlocalplaces.com/images/85-honda-spree-manual.pdf Disarming during an opening window or arming during a closing window does not send a report to the central station. If the system is not disarmed or armed during the appropriate window, a Failed to Open or Failed to Close message is sent to the central station. You can choose from a list comprising three opening and four closing window times. The times in this list can be programmed according to the user s entry and exit scheduling requirements. If required, the user can issue the Late to Close command to extend the closing window period. The Auto-Arm feature causes the system to arm itself automatically at the end of the closing window. This prevents situations where the system is left unarmed at the end of the day. Latch-Key The latch key feature has been designed to inform parents whether their children have arrived home safely and on schedule. Event Log The event log records the last 100 events the system has undergone. The event log uses the FIFO (first in, first out) method. Once the log is full, the oldest event will automatically be erased. You can view the event log with the LCD keypad or the RP software. This code is designed to enable you to perform initial programming tasks. Activating Dealer Lockout disables this feature and the code can only be restored using the RP software. -7- Using microphones installed on-site, the central station operator can distinguish between an actual break-in and a false alarm. In order that the siren will not interfere with the operator s ability to listen-in, the siren is not sounded until the end of the Listen-In period. The Bell Muting feature (programmed at address 495) delays bell activation until after all pending messages have been sent to the central station. The system chooses this delay at random in order to prevent the central station being simultaneously inundated by AC Loss reports in the event of a regional power cut. If AC power is restored before the event message is sent, the event message is cancelled and will not be sent. The AC Restore message (address 248 or 282) is also sent at random using the same method described above. AC Restore is reported only if the AC Loss report was sent. -8-. The metal cabinet includes mounting and wiring holes on the rear, optional wiring knockouts on the sides and dedicated positions for the various peripheral modules available for use with the control panel.This is in order to ensure proper system operation, provide effective lightning and transient protection and also protect against electrical safety hazards. Note: The connection to earth ground must be direct. It is not sufficient to ground the panel only using the 3-pin plug that is connected to the electrical socket. Power connection to the unit should be according to the national electrical code for permanent installation. 2.4: Installing Keypads The Summit 3208GLD security system supports the keypads pictured in Figure 2.2. The layout for each keypad differs but the installation and operation instructions for all the keypads are identical LED 3108 LCD 3118 LCD 3128 LCD Figure 2.2: 3208GLD Keypads All keypads are supplied configured to keypad address 1 in unsupervised mode.If more than one keypad is installed with same unit address, all keypads must be configured as unsupervised. To configure the keypad unit address: 1. Using a small flat-head screwdriver, open the back cover of the keypad. 2. Locate the jumpers marked CBA. 3. Install the jumpers according to Figure Disconnect and re-connect the power supply. Keypad 1 Keypad 2 Keypad 3 Keypad 4 CBA Keypad 5 Keypad 6 Keypad 7 Keypad 8 CBA Jumper installed Jumper removed Figure 2.4: Keypad Unit Address Jumper Configuration Keypad supervision If a supervised keypad is disconnected, the control unit sends an LSCP Unit Tamper message (address 239 or 273) to the central station. Note: The LSCP Unit Tamper message is also sent when the keypad s tamper switch is opened. This event message is sent regardless of the keypad s supervision setting. To configure the keypad supervision setting: 1. Using a small flat-head screwdriver, open the back cover of the keypad. 2. Locate the jumper marked S. 3. To configure the keypad in supervised mode, remove the jumper. Supervised S Unsupervised S Figure 2.5: Keypad Supervision Jumper Configuration LCD Contrast Adjustment If the LCD display is unclear, the contrast may be adjusted using the LCD contrast trimmer. Bright Dim Figure 2.6: LCD Contrast Trimmer -11- Refer to the testing procedure found in the installation manual Receiver communication must be tested monthly. For maximum current calculation, add keypad consumption (approx. 60mA per keypad) to the total current drawn from the AUX power output. Install vertically to supply 9-18V unregulated to bell and terminal 28. Fire: Supplies 220mA for 24 hours.Outgoing line to telephone: Terminal 1 - Home Tip, Terminal 2 - Home Ring Incoming Line from telephone company: Terminal 3 - Telco Tip, Terminal 4 - Telco Ring.Microphone Terminal 23: Microphone input for listen-in applications. The smoke detector output is active low and is restored either automatically or manually. The power requirements are as follows: AUX power (12Vdc nominal regulated, 9-18VDC unregulated), rated at 600mA with 40VA transformer. 12V Unregulated Power Output Terminal 28: This terminal provides 12V unregulated power when fuse F3 is installed in the vertical position. AC Power Input Terminals 29, 30: Connect a 15VAC Class II transformer rated at 30VA, using 18AWG wire. -13-. Install vertically to supply 9-18V unregulated to bell. Fire: In accordance with CSFM (Fire) supplies 220mA for 24 hours.Microphone Terminal 23: Microphone input for listen-in applications. The smoke detector output is active low and is restored either automatically or manually. The power requirements are as follows: AUX power (12VDC nominal regulated; 9-18VDC unregulated), rated at 600mA with 30VA transformer. AC Power Input Terminals 28, 29: Connect a 15VAC Class II transformer rated at 30VA, using 18AWG wire. -15- You must define the zone s loop type accordingly at the 3 rd address of each zone s programming parameters. Note: D.E.O.L.R. zones are available only for DK firmware versions. For D.E.O.L.R. zones, do not install more than ten sensors in a circuit. Tamper Zone Com. Zone X Tamper Zone Com. Zone X Tamper Zone Com. Zone X Zone X Tamper Alarm Tamper Alarm Tamper Alarm Tamper Alarm 2.2K Tamper Alarm Tamper Alarm Tamper Alarm Tamper Alarm 2.2K 2.2K 2.2K N.O. N.C. E.O.L.R. D.E.O.L.R. 2.10: Fuse Replacement Figure 2.8: Hardwire Zone Loop Types The following diagram shows the 3 protection fuses on the Summit 3208GLD s main circuit board. F2 (AUX Power Output Protection Fuse): Protects terminals 6 (keypad power), 21 (AUX output) and 24 (smoke detector power output). When the fuse is installed in the horizontal position 12VDC nominal regulated power is supplied to the bell. When the fuse is installed in the vertical position, unregulated (approx. 9 to 18VDC) power is supplied to the bell and terminal 28. MAKE SURE YOU REPLACE A FUSE WITH THE CORRECT RATING! 2.11: Turning on the System Once all of the systems components are properly connected and you have checked the connections, the Summit 3208GLD is ready to be turned on. To avoid the risk of electric shock or damage to the control panel, make sure that both the AC supplier and the battery are connected properly before applying power to the system. -16-. On the LCD keypad, you can scroll backwards using the key during menu navigation and programming. Pressing the key cancels the entry and exit delays for the current arming period. SELECT: Pressing SELECT, followed by a command code, issues a command to the system. On the LCD keypad, this key is also used to select menu items. STAY: The STAY key is used to arm the system's perimeter zones. AWAY: The AWAY key is used to arm the whole system (both perimeter and interior zones). AWAY is also used to exit the current operation (e.g. programming or view log) Note: If one-key arming is enabled, the user can arm the system using the STAY and AWAY keys without having to enter a user code. Status Indicators ARMED: On when the system is armed, off when the system is disarmed. POWER: On when both the AC and the backup battery are connected, provided that the voltage supplied by the battery is over 10.8V and AC power supply is between 50-60Hz. The indicator blinks slowly when the battery is low and turns off to indicate AC power loss. Note: If the keypad is programmed to display all systems, the Armed LED lights up only when all systems are armed. For DK firmware versions, during the arming period, the Armed LED flashes quickly after an alarm occurrence. When disarming after an alarm, the Armed LED flashes periodically. This indication is reset by arming the system, viewing the entire event log or clearing the log. -17- Pressing any key on the keypad terminates these chimes. LED Keypad Operation (3106) Figure 3.2: 3106 LED Display The 3106 LED keypad is designed for use as an additional arming station. Electronics Line strongly recommends that you do not use the LED keypad to perform any complex procedures that require detailed feedback from the system, such as programming. The following is a summary of the LED display: 1-8: Used to display zone status. The relevant LED is lit if the zone is open, flashes slowly if the zone is bypassed and flashes quickly if the zone was violated in the last arming period. The keypad s system defines which zone expander is associated with the keypad, i.e. which zones are displayed by LEDs 1-8. See Addresses for keypad system allocation. System 1 (Zones 1-8): Zone Expander A System 3 (Zones 17-24): Zone Expander C System 2 (Zones 9-16): Zone Expander B System 4 (Zones 25-32): Zone Expander D If zone expander A is not in use, the control panel s 8 onboard zones are displayed from a System 1 keypad. Note: For all zones to be displayed on LED keypads, the zones must be assigned to the correct system in programming. For example, if zones 1-8 are not assigned to System 1, their zone status will not be displayed by any LED keypad. BYPASS: Indicates if zones have been bypassed. The Bypass LED and the relevant zone LEDs blink to indicate that zones have been bypassed. READY: Indicates if the system is ready to arm. If lit, the system is ready and if the LED is flashing quickly, the system is not ready to arm. This LED is off when the system is armed. PROGRAM: The Program LED lights up if SELECT is pressed and flashes to indicate that the system is waiting for a user code to be entered. TROUBLE: Flashes if a trouble situation exists within the system (telephone communication and siren supervision failure). -18- This display provides a convenient user interface for operating and programming the Summit 3208GLD control panel. The following section shows typical LCD displays and offers a short description of each message. Zone 1, Bedroom, is open ZONE 1 OPEN BEDROOM Zone 3, Front Door, has been bypassed ZONE 3 BYPASSED FRONT DOOR Zone 4 has been tampered with ZONE 4 TAMPER Zone 4, bedroom, is in alarm ZONE 4 IN ALARM BEDROOM System Status Display AC power has been disconnected: SYSTEM AC LOSS Backup battery is low (under 10.8V) or has been disconnected: Communication failure or the telephone has been disconnected: SYSTEM LOW BATT TELEPHONE COMM. FAILURE Time and Date display (scrolls every few seconds): THU 28 JUL 94 12:37-19- To abort at any time, press AWAY. 3. Press SELECT to choose the displayed menu item. Certain functions may require you to enter an authorized passcode.This method should be used when the user is leaving the premises. To Away arm the system: 1. Check that no zones are open (i.e. all entrances are secured and the premises are empty) so that the system is ready for arming. 2. Press AWAY. 3. Enter an authorized user code; the LCD displays SYSTEM X ARMED, XX SEC TO EXIT! 4. Exit the area within the exit delay count down. Note: Failure to exit during the exit delay will result in an alarm. Entering an authorized passcode also Away arms the system. Stay Arming Stay arming activates the system s perimeter zones. Stay arming is used when the occupant is remaining on the premises. If one-key arming is enabled it is not necessary to enter a user code when arming the system with the STAY and AWAY keys see addresses Disarming Disarming deactivates the system. When the user opens a zone with an entry delay, the entry delay counts down. The system must be disarmed during the entry delay to prevent an alarm being generated. If the entry delay expires and the system is still armed, the siren sounds and the user has twenty seconds to disarm before a report is sent to the central station. To disarm the system: Enter an authorized passcode. If the system is in alarm, entering an authorized passcode disarms the system and terminates the alarm. 3.6: Additional Arming Methods Forced Arming Forced arming enables the user to arm the system even if all zones are not secured. If zones are still not secured after the exit delay has ended, an alarm will be generated. The ability to force arm the system is a programmable option see address 494. Note: Electronics Line recommends waiting until all of the zones are secured and the system can be armed normally. Immediate Arming The system can be immediately armed, canceling the entry and exit delay for the arming period. Different user code authorization levels restrict certain functions to specific users. That is to say, of the 15 users that are able to operate the system, not all of them have access to all system operations. For example, an installer with a level 12 user code can only test and program the system. The installer does not have the ability to arm and disarm the system, which maintains a high level of security for the user. Each of the 15 user codes can be programmed with 3 to 6 digits.The user code is assigned to System 1. The user code authorization level is 10. Note: A user cannot program a code to a higher access level or to a sub-system other than the one to which their code belongs. Additionally, a user cannot view user codes assigned to a higher access level. The system accepts the first user code it recognizes. To prevent being locked out of the system, do not program user codes beginning with the same numeric combination. For example, the 3 digit user code 123 and the 4 digit code 1234 are programmed in the same system. Any attempt to enter 1234 is impossible as the system recognizes 123 the moment the third digit is entered. User Codes and System Partitioning When the Summit 3208GLD is partitioned into several sub-systems, user codes can be associated either with a specific sub-system or with the entire system. Assigning a user code to only one system will default all operations to that system. For example, if a user code is assigned to System 3, entering the code arms System 3 without the need to indicate the system number. A user code authorized to all of the subsystems can perform functions affecting the entire system, such as arming. To assign a user code to all of the systems, program the code as belonging to System 5. Duress Code The duress code is a user code designed for situations where the user is being forced to operate the system. This user code performs the selected operation, while sending the duress event message (address 259 or 293) to the central station. A duress code has an authorization level of 15. Note: In the message to the central station, the control panel always indicates the system of the keypad from which the duress code was entered. 3.8: Distress Keys In the case of an emergency, 3 types of alarm can be generated from the keypad. A zone can only be bypassed if it is programmed as bypassable - see parameter addresses Bypassing and unbypassing can only be performed if the system is disarmed. To bypass a zone: 1. Press SELECT 3, Enter an authorized user code and a zone number. 3. Press AWAY to exit. Note: On a control panel with zone expanders, the control panel waits for an extra digit when zones 1, 2 or 3 are bypassed. This allows bypassing of the additional zones (for example, 11, 24, or 32). To unbypass a zone: 1. Press SELECT 3, Enter an authorized user code and the bypassed zone number. 3. Press AWAY to exit. -23- 24 To unbypass all zones: 1. Press SELECT 3, Enter an authorized user code. 3.10: Event Log The event log records the last 100 events the system has undergone. The event log uses the FIFO (first in, first out) method. Once the log is full, the oldest event will automatically be erased. The event log can only be viewed with the LCD keypad. The events are displayed starting with the most recent event registered in the log. 4. Press AWAY to exit the log. The following table shows examples of typical event log displays. Event Display Day 23 in month, time 12:45, alarm from Zone 2, Bathroom 23 12:45 ALARM BATHROOM, 02 Day 23 in month, time 12:50, system 1 was armed (perimeter) by user 11. Print Event Log The 3800 is an LSCP add-on module that provides the Summit 3208GLD with a parallel printer port, enabling the user to print the event log. To print the log: 1. Press SELECT 6, Enter an authorized user code; the log is sent to print. 3.11: Tests Walk Test The walk test allows detection devices to be tested without generating an alarm. To perform a walk test: 1. Press SELECT 4, 2, Enter an authorized user code. 3. Test the control panel s detection devices; an opened zone causes the keypad to beep. 4. To end the walk test, press AWAY. Walk test mode is automatically terminated after 4 minutes. -24- 25 Note: During a walk test, an open zone will not create an alarm. Bell Test To perform a bell test: 1. Press SELECT 4, 2, Enter an authorized user code; a 1-second ring is heard and the test is terminated automatically. Telephone Communicator Test To perform a telephone communicator test: 1. Press SELECT 4, 2, Enter an authorized user code; a test message is sent to all central stations that are programmed to receive communications from the control panel. The control panel returns to normal operation after the telephone communication test is initiated. The report code for this message is at address 251 or 285. Note: The control panel seizes the telephone line to run this test. System Test To perform a system test: 1. Press SELECT 4, 2, Enter an authorized user code; the system tests the control panel s electronic circuitry. Should the LCD display the message System Failure, contact our technical support department. Battery Test To perform a battery test: 1. Press SELECT 4, 2, Enter an authorized user code; the battery is tested under loading conditions, the control panel returns to normal operation and the battery status display is updated. For the test to be successful the voltage must not be lower than 10.8V under loading conditions. Bell Cancel To cancel bell operation: Enter an authorized user code. If the system is armed, this cancels the bell and disarms the system. If the system is disarmed, only the bell is cancelled. Note: When the system is armed, entering the Master Code (Level 10) only cancels the bell and does not disarm the system. When the keypad is mounted outside the protected area or when the system is armed using the Stay method, you may want to cancel the bell without disarming. To cancel bell operation without disarming the system: 1. Press SELECT, 4, Enter an authorized user code. -25- View more ARMED Light is on when armed; off when disarmed; flashes to indicate a previous Should you have any questions or comments, please visit www.paradox.com and send Control Panels PIMA Electronic Systems Ltd. www.pima-alarms.com The DESTINY has been designed to provide you with a maximum level of security Hereby, Electronics Line 3000 Ltd.We understand the importance Quick Guider After getting this alarm system, you need to do the following Installation and User Manual WARNING This manual contains information on limitations regarding product use and function The entire manual should be carefully Operating Guide. Proudly Designed and Manufactured in New Zealand Should you have any questions or comments, please visit www.paradox.com and send us User s Manual All rights are reserved.you may download User s Guide On every system s arming the counter is cleared in self. 6.3.11. 2 - Triger Timer - enter a Paul, MN 55109 FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved The system can be programmed to communicate with a central monitoring station These instructions do not purport to cover all details or variations in equipment nor to provide every Should you have any questions or comments, please visit www.paradox.com and send us your comments. Table of Contents Use only numeric keys Enter Dealer Code to exit or press the C key to return to Dealer User s Guide. Version 9.08.2 To use this website, you must agree to our Privacy Policy, including cookie policy. Discover everything Scribd has to offer, including books and audiobooks from major publishers. Start Free Trial Cancel anytime.