Error message

Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home1/dezafrac/public_html/ninethreefox/includes/common.inc).

7

elcometer 130 manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:elcometer 130 manual.pdf
Size: 3572 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 27 May 2019, 15:37 PM
Rating: 4.6/5 from 732 votes.

Status: AVAILABLE

Last checked: 14 Minutes ago!

In order to read or download elcometer 130 manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

elcometer 130 manualApple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance. App Store is a trademark of Apple Inc., registered in the U.S. and other countries.The Elcometer Calibration Verification Tiles are used to check each gauge’s measurement electrodes by accurately simulating known salt concentrations. Click here to download the video script in English. Thank you for your purchase of this Elcometer 355 Coating Thickness Gauge. The Elcometer 355 Coating Thickness Gauge is a hand-held gauge for fast and accurate measurement of coatings thickness on ferrous.Reload to refresh your session. Reload to refresh your session. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below. Copyright Elcometer Limited. 2009. All rights reserved. Welcome to Elcometer. Elcometer are world leaders in the design, manufacture and supply ofinspection equipment for coatings and concrete.Our products cover all aspects of coating inspection, from development throughapplication to post application inspection.The Elcometer 130 SCM400 Salt Contamination Meter is a world beatingproduct. With the purchase of this product you now have access to theworldwide service and support network of Elcometer. For more information visitour website at www.elcometer.com 1 ABOUT YOUR METERThe Elcometer 130 SCM400 Salt Contamination Meter measures saltcontamination levels on metallic and non-metallic surfaces and is particularlyuseful on areas such as bends and welds. 1.1 StandardsThe instrument can be used in accordance with the following InternationalStandard: SSPC Guide 15. 1.http://www.winnerjudo.pl/zdjecia/fck/datacard-sp55-plus-user-manual.xml

    Tags:
  • elcometer 130 manual, elcometer 130 manual pdf, elcometer 130 user manual, elcometer 130 scm 400 manual, elcometer 130 manual, elcometer 130 manual transmission, elcometer 130 manual pdf, elcometer 130 manual transfer switch, elcometer 130 manual instructions.

2 What the box contains Elcometer 130 SCM400 Salt Contamination Meter Carry Case and nylon Shoulder Strap High Purity Sample Papers (pack of 100) Plastic Tweezers (2 off) Self-Seal PVC Bags (pack of 20) Replacement Pressure Support Pads (pack of 8) Disposable Gloves (pack of 20) in nylon holdall Pack of Tissues 9 V Alkaline Battery 2 ml Syringes (3 off) Bottle of High Purity Water (250 ml) Plastic Sample Bottle Operating Instructions T 3En glis h2 PRINCIPLE OF OPERATIONSoluble salts on the surface are taken into solution by placing a wetted 110 mmdiameter Elcometer 130 SCM400 High Purity Sample Paper on the area to besampled.By leaving the paper in contact for a timed period, salt removal from the surfaceis maximised. Using a paper of known size allows contamination to beexpressed in terms of surface area.These papers retain a known amount of water because of their consistentabsorbency characteristics and therefore the concentration of the solutionformed is related to the quantity of soluble salts removed.The sample paper containing the salt solution is placed over the electrodes onthe Elcometer 130 SCM400 and its resistivity is determined. This is achieved bymeasuring the minimum resistance of the solution over a fixed solution pathlength and cross section, governed by the electrode spacing and paperthickness respectively.The solution concentration is inversely proportional to its resistivity. TheElcometer 130 SCM400 relates the latter to a calibration with known 4En glis h concentrations of sodium chloride solution and the known surface areasampled, to give surface salt levels in g.cm-2. Figure 1. Elcometer 130 SCM400 Salt Contamination Meter 3 SPECIFICATION OF SALT LEVELSIdeally, the salt level remaining on a steel surface after surface cleaning andprior to painting or any other construction operation, should be zero.In practice it is not possible to achieve this due to various environmental factorsand a working salt level needs to be specified.http://www.zulassungsdienst4you.de/bilder/datacard-sp55-parts-manual.xml In the case of painting, this levelis a matter for discussion between the Client, the Applicator and the PaintManufacturer and it will depend on the working conditions, the paint systemused, the required service life and what can be economically achieved.Consequently, it is not possible to specify in these Operating Instructions whichsalt standards are best suited to all industries. However, during thedevelopment of the Elcometer 130 SCM400, the effect of salt contamination onthe life of coatings under a range of realistic and accelerated environmentalconditions for a number of common generic coating systems was assessed. 5En glis hAlthough Elcometer would not wish to recommend this as a specification, thework has shown that a salt level of better than 4 g.cm-2 is a sensible workinglimit. 4 TAKING A READING 4.1 Before you start Is the electrode (Figure 1) clean. See Removing and cleaning or replacing the electrodes on page 14. Is the sampling water to the correct specification, i.e. BS 3978 (ISO 3696) - Water for Laboratory Use, Grade 3?See Spares and accessories on page 18 for replacement water If the sample area is larger than the Elcometer 130 SCM400 High Purity SamplePaper, follow procedure 4.2.If the sample area is smaller than the Elcometer 130 SCM400 High PuritySample Paper, follow procedure 4.3. 4.2 Taking samples using standard sample papers1. Put on a pair of clean disposable gloves.2. Fill a 2 ml syringe with precisely 1.6 ml of high purity water.3. Using tweezers, remove an Elcometer 130 SCM400 High Purity Sample Papera from the pack.If the standard 110 mm diameter sample paper is too large for the area tobe sampled, smaller papers may be used - see Taking samples usingsmaller sample papers on page 8. a. Use only Elcometer 130 SCM400 High Purity Sample Papers. Commercial filterpapers are not suitable as they can contain excessive salt levels. 6En glis h 4. Using the tweezers to hold the sample paper, eject 1.http://www.bosport.be/newsletter/boss-dd-20-instruction-manual6 ml of water onto itssurface (Figure 2), taking care to retain as much water as possible on thepaper. Figure 2. Applying Water to Elcometer 130 SCM400High Purity Sample Paper 5. Place wetted paper on the area to be sampled, pressing it firmly into itscontours and surface irregularities. 6. Press out as much entrapped air as possible from beneath the paper. Ifhand pressure is required to exclude air, the gloved hand should not beused. Instead, turn one of the plastic bags provided inside out, place it overthe gloved hand and press the surface, discarding the plastic bag whenfinished. 7. Switch the Elcometer 130 SCM400 on by pressing the red pushbuttononceb. The display will show: 8. When the sample paper is in position, press the red pushbutton again tostart the 2 minute timerc. When 2 minutes have elapsed the Elcometer 130 SCM400 emits anintermittent bleep and the display shows: 10.Remove the sample paper from the surface.11.Place the sample paper over the concentric copper electrodes (Figure 3) ensuring that the outer ring is completely covered. JSFiddle or its authors are not responsible or liable for any loss or damage of any kind during the usage of provided code. Eject the 1.6ml on to a clean unused sample paper, taking care to retain all the water on the paper. Place wetted paper on to the area under test, pressing firmly into contours and irregularities to remove any entrapped air. Start the timer on the gauge. Whilst waiting for the sample time to elapse, additional tests can be prepared. After 2 minutes, remove the paper from the surface and place it on to the gold-plated electrodes. Close the lid, ensuring that the magnetic catch is fully engaged. The reading will automatically be displayed and stored into memory together with paper size, temperature, date and time. Half size or quarter size papers can be used for testing on small surfaces. Paper size is automatically detected by the Elcometer 130 and the reading calculated automatically.http://oldsaltsclub.com/images/04-honda-civic-manual-transmission.pdfAll rights reserved. Please upgrade your browser to improve your experience. You need JavaScript enabled to view it. This email address is being protected from spambots. You need JavaScript enabled to view it. So this website was intended for free download articles fromYou are self-liable for your download.You can learn how to disable cookie here. Automatic temperature compensation ensures accurate results Fast reading rate allows multiple tests to be completed efficiently Pressure plate ensures a constant and uniform pressure to paper Non-oxidising gold plated contacts ensures lifetime accuracy Stores up to 100,000.Automatic temperature compensation ensures accurate results Fast reading rate allows multiple tests to be completed efficiently Pressure plate ensures a constant and uniform pressure to paper Non-oxidising gold plated contacts ensures lifetime accuracy Stores up to 100,000.Elcometer 130 Model T: Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPad Air 2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and iPod touch (5th generation). Made for iPod, Made for iPhone, and Made for iPad mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. 3 Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance. 2. Surface Preparation - Cleanliness Salt Contamination Meter Elcometer 130. Designed with you in mind User Friendly Tough Large buttons ideal for gloved hands Heavy duty, impact resistant, dust and Easy to use menus in multiple languages waterproof design equivalent to IP64. High reading limit indicator Wipe clean sealed unit ideal for harsh environments Factory calibrated for immediate use Scratch and solvent resistant display Accurate Conductivity measurement to 1. Repeatable and reproducible (3000ppm). Bright colour screen; with permanent back light. USB power supply; via PC. Calibration certificate. Calibration verification mode (with optional certified calibration tiles). Ambient light sensor; with adjustable auto brightness. Emergency light mode. Data output USB; to computer. On screen statistics. Number of readings (n); Mean (average) (x) -; Standard deviation ( ). Highest reading (Hi); Lowest reading (Lo); Coefficient of variation(CV). Number of readings above high limit ( n ). Gauge memory. Number of readings 100,000. Number of batches 1,000. Measurement mode Surface cleanliness. Conductivity. Calibration offset mode. Automatic temperature compensation. Alpha-numeric batch names; user definable on the gauge. Fixed batch size mode; with batch linking. Delete last reading. Trend graph; last 20 readings. Batch review graph. The warranty can be extended to two years via. Visit to find out how to integrate Elcometer 's MFi certified products to your App. 4. Surface Preparation - Cleanliness Salt Contamination Meter Elcometer 130. Technical Specification C. 8 Model S Model T Description Certificate E130-S E130-T Elcometer 130 Salt Contamination Meter E130-SC E130-TC Elcometer 130 Certified Salt Contamination Meter. Power Supply 4 x AA batteries (rechargeable batteries can also be used), or power via USB. T99922341 Pack of 10 Display Screen Protectors T13024093 Box of 20 Self Seal Polythene Bags T99911344 Pure Distilled Water - 250ml ( oz) Bottle with 3ml syringe T13027596 Pure Distilled Water - 1000ml ( oz) Bottle with 3ml syringe T13024094 Box of 100 High Purity Test Papers T13024092 Box of 20 Disposable Vinyl Gloves T13024098 Plastic Tweezers (x2). 10 T13024087 Box of 72 Sensor Wipes T13025964 Magnetic Discs (x3). T99921325 USB Cable Calibration certificate supplied as standard 5. ENGLAND. Elcometer Limited Manchester M43 6BU.Welcome to Elcometer. Elcometer are world leaders in the design, manufacture and supply of coatings inspection equipment. To insert or replace the batteries: Batch Calibration Certificate supplied as standard. Viscosity Flow Cups Viscosity Flow Cups are very easy to use instruments made of anodized aluminium with a stainless steel orifice, for measuring the consistency of paints, varnishes Range of operation (flow rate) is specified for each water meter. Please complete the form below and one of our sales representatives will contact you with further details about this product. You can also talk to us directly on 1300 503 610 during business hours. Notice: JavaScript is required for this content. All Rights Reserved. Developed By papdan.com. Robust temperature sensors A hand-held Dewpoint meter with both manual and automatic data logging in one gauge Easy to use, intuitive menu structure Integrated magnets allow the gauge to be attached to the substrate during remote logging Visual and audible indication of user defined limits for any or all parameters Dustproof and waterproof gauge with fully sealed sensors (equivalent to. Image Collection Use measurement location points on images to indicate the position for the next reading. Combine Combine different inspection parameters (such as climate, DFT, surface profile, surface cleanliness and. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. If you continue browsing the site, you agree to the use of cookies on this website. See our User Agreement and Privacy Policy.If you continue browsing the site, you agree to the use of cookies on this website. See our Privacy Policy and User Agreement for details.If you wish to opt out, please close your SlideShare account. Learn more. You can change your ad preferences anytime. A wide range of probes is available to suit requirements.I had some fun and got a great deal. OOO And in just 25 minutes, I reconditioned the battery and it works fantastic again.The New Elcometer 456. Coating Thickness GaugeSeparate: 161g (5.68oz) including batteries. Applicable patents: US6243 661; US5886522; US6762603; US7606671;Elcometer Limited.Pb HgThickness Gauge. Welcome to Elcometer. Elcometer are world leaders in the design, manufacture and supply ofOur products cover all aspects ofThe Elcometer 456 Coating Thickness Gauge is a world beatingFor more information visit www.elcometer.comThe gauge is available in four models; Model E, B, S andT. This manual describes the operation of all the Elcometer 456 modelsAll versions of the gauge feature an easy-to-use menu drivenThe gauge is available either with a built-in integral probe or as aA wide range of probes is available to suitAs an example, the Languages option is located within Setup which isThe gauge is packed in cardboard packaging. Please ensure that thisPlease Consult your Local Environmental Authority for furtherGauge OverviewBox ContentsYour gauge is supplied with batteries ready to fit. To insert orThe battery condition is indicated by a symbol in the top right of theTo maximise battery life, ensure that Auto Screen Brightness is. Bluetooth radio button. Connecting the probe (separate gauges only)Fitting the wrist harness. Awrist harness is supplied with each gauge. This can be fitted into theThe gauge will switch off automatically after 5 minutes of inactivity. Auto Off radio button. Selecting a language. When the gauge is switched on for the first time after dispatch from the. Elcometer factory the display will show the language selection screen:To access the language menu when in a foreign language:Selecting units. The Elcometer 456 can display readings in both metric and imperialThe appropriate measurement unit can be changed via. Adjusting the beep volume. Each time a measurement is taken, the gauge will beep. The beepThe calibration of the gauge can be adjusted using several differentFoils can also be stacked to increase the thickness value. The calibration method is indicated on the screen by a symbol - see. Multiple Calibration Methods on page 18. Not all calibration methods are available for all gauge types. For aWhen using an FNF probe it must be calibrated in both the ferrous modeCalibration Methods on page 18. For more information on calibrating the Elcometer 456, see page 60.If you see the Cal softkey flashing, the gauge should be calibrated.For a complete list of icons, see “Gauge Icons” on page 66 - 68The character size of the measurement value onTo maximise the reading size, either. Y reduce the number of statistical values that. Statistics, or. Y display the reading only by checking theFast reading rate (EBST). The Elcometer 456 is capable of taking greater than 70 accurate,Easy to use menu structure in more than 30 languages (EBST). Designed to be intuitive, the Elcometer 456 menus and calibrationBright colour screen (EBST)Battery or USB Powered (EBST). Each gauge can be powered either using 2 x AA lithium, alkaline orTwo year gauge warranty (EBST). The Elcometer 456 gauge is supplied with a 1 year warranty againstTo extend this warranty to 2 years, simplyEmergency light mode (BST). If all the lighting fails during an inspection in dark environments, the gaugeUsing the internal accelerometer, the gaugeThis function can be switched off by un-checking. Rotation. Gauge firmware updates (BST)When the Elcometer 456 is connected (via USB), to any computerCaution, before upgrading your gauge firmware, ensure that you haveElcometer 456 gauges have the ability to transfer data via USB (BST). For more information. Users can download data from any Elcometer gauge directly intoHi BST Highest reading taken. Lo BST Lowest reading takenOnce the data has been transferred to the computer, the user canData can also be transferredDownloading Data. Counted Average (BST). Users can define the number of individual gauge readings to be takenCounted Average is also available when in Batching (ST) - see. BatchTypes on page 32. On Screen Statistics (BST). User selectable statistical and general measurement information canThe information to be displayed can beY Up to 8 statistics can be selected to be displayed on the reading. The following statistical and general information can be displayed onNDFT ST Nominal dry film thickness; The target or specified dryIMO PSPC ST International Maritime Organisation’s Performance. Standard for Protective Coatings clearly defines theThe Elcometer 456Nominal Dry FilmThickness Value.Y At least 90 of all dry film thickness readings shallY none of the remaining measurements shall be belowX! ST If all the measurements taken at any point are greaterStatistically, however, were more measurements to beThis is depicted by thePSPC seeAbout IMO PSPC on page 74. ST Low Limit. ST High Limit. ST Number of readings below the low limit. ST Number of readings above the high limit. User definable warning limits can be set. Once theThe values on the top left and right of the barIf limits areWith Limits: The current measurement isIf below the lower limit, the left arrow headIf the next measurement taken is within set limits, the left or right arrowWithoutLimits:Thecurrentmeasurementisdisplayedasawhitebar. If outside the measurement range, the left or white arrow head is alsoIf the next measurement taken is within range, the left or right arrowThe graph is updatedY Highest reading in the batch “ ”. Y Lowest reading in the batch “ ”Y Mean of readings in the batch “ ”Y High limit for the batch “ ” (when enabled). Y Low limit for the batch “ ” (when enabled). The readings are displayed as white or red points; white if a reading isWhen in Scan Mode (T) - see Measurement Modes on page 25, the. Analogue Bar Graph is displayed on screen whilst scanning. This isThe highest and lowest reading for eachThe highest, average and lowest readingChart is only available when in Batching, it is not available in Standard (Immediate). Mode. Time and date (ST). Date), the user can display the time and date at the top of the ElcometerDate Format. Please note that the time and date is replaced by the batch nameWhen a batch is created, re-opened (or when the gauge is switchedThe time and. Multiple calibration methods (EBST). Calibration adjustment is the process of setting the gauge to knownThe calibration of the gauge can be adjusted using several differentStandards and the calibration adjustment method chosen depends onThe calibration method is indicated on the screen by a symbol. When using an FNF probe it must be calibrated in both the ferrousMode (see Measurement Modes on page 25), it must be calibrated. When switching between the Scale 1 and Scale 2 functions of theZero A simple method for calibrating on smoothAlso known as the singleThe gauge’s on-screen calibration instructionsWhen selecting the foil value, the user shouldIdeal for calibrating the gauge on both profiledThe calibration requires 2 foil values - one aboveThe gauge will guide the user through theFine 10 (0.4). Medium 25 (1.0). Coarse 40 (1.6)Auto This is a calibration method unique to the. Elcometer 456 and has been designed to simplifyWhen the Auto calibration method is selected,Once these foil values have been set up,Elcometer 456 returns the calibration to theThe factory calibration method should only beIn addition to the standard calibration methods described on pagesThese pre-defined calibration methods not only define the calibrationFor this reason, pre-defined calibration methods can only be selectedFor more information onISO Sets the calibration method to Zero Offset andElcometer 456 on page 60. User-programmable calibration memories (T). The Elcometer 456 Model T allows users to store into memory up toCalibration memories are ideal for users who are inspecting coatingsUsing the gauge’s alpha-numeric function, users can re-name theFor example. Y A user who is inspecting coatings on two blast profiles - shot andY A user measuring on flat and curved surfaces could store the. Y Thick and thin coating thickness calibrations can also be saved. For more information on re-naming calibration memories, see Alpha-In order to achieve the most accurate reading the gauge should beWhen using the gauge’s calibration memories, or batching (see. Batching on page 26) different calibration foil values may be used inCalibration lock (BST). To avoid accidental amendments to the calibration settings switchingWhen the Calibration Lock is enabled, users can still test theThe calibration can also be locked using a PIN Code, see page 63 forOnce the Outside calibration warningThe Elcometer 456 versions are supplied with a varying level ofModel E: No memoryThe last 5 readings,Model S: 1,500readingscanbestoredintothegauge’smemory. Model T: A total of 150,000 readings can be stored into theLimits (ST). During the inspection process coatings can often have specified. For example, coatings that have been applied too thinly over aTo switch the limits on, the user should ensure that the Enable LimitsY When an Upper Limit has been set up and enabled the “ ” icon isY When a Lower Limit has been set up and enabled the “ ” icon isY If both Upper and Lower limits have been set up and enabled thenY The Red LED flashes. Y The reading is displayed in red. Y The alarm beeps 3 times. Y The associated limit icon turns red. In addition, the number of readings above limit (or below limit asIn Batching, the reading isThe programmed limit values can be displayed on the reading screenIf a low limit has been set up, the upper limit value cannot be lowerIndividual limits can also be set up for each batch on Model T gauges. For more information see Batching on page 26. Gauge Welcome Screen (BST). Users can adjust the start up screen on their Elcometer 456 gaugesStandard (Immediate) Mode (ST): Where readings are taken, rollingScan Mode (T): Specifically designed for use with Elcometer 456When Batching,Scan Mode with Hold (T):As above but allows the probe to be lifted offAuto Repeat Mode (T): When the probe is placed onto the coatedWhenBatching,eachindividualreadingisstoredintothememory.Use in these modes without the cap willBatches allow theThe Elcometer 456 has the following batching functions. Y Copy a batch - including all calibration and limit setups (T). Y Clear all the readings within the batch - but leaving all calibration. Y Review the readings, statistics, calibration, batch information (ST). Y Delete a Batch (ST), or all batches (T), entirely from the gauge. Y Delete the last reading entirely or delete the reading, but mark the. Without Tag respectively. Creating a new batch (T). When using batching for the first time, or when you wish to open a new. Cal Memories on page 27)Y Choose the type of batch (normal, counted average or IMO PSPC). Types on page 32)When in batching - or setting up a calibration memory (see Calibration. Memories on page 21) - the user can rename the batch or cal memoryWhen a new batch is created, the gauge automatically names it. Batch 2, Batch 3, etc. To rename a batch either. Batch 1; orTo rename a calibration memory. This then opens up the renaming procedure to enable the user toUsing the left arrow, right arrowThe yellow, raised character orPressing the Esc softkey at any time cancels the whole operationCharacter ActionDeletes the last character of the name. A, B, C. Selects the character A, B or C, etc. Inserts a spaceChanges the selection characters to. Changes the selection characters to:To open a particular batch use the up and down arrow soft keys andThe Elcometer 456 will return the gauge to the main reading screenAs the Model S only has one batch, the batch will open automatically. Copying an existing batch (T)To copy a particular batch use the up and down arrow soft keys andThe Elcometer 456 will then copy all the batch settings - calibrationPressing the Yes softkey the user will then be asked to rename thePressing the No softkey (or pressing the Esc softkey whilst in theCopying a batch does not copy the individual readings within thatClearing an existing batch (ST)To clear a particular batch’s individual readings only, use the up andAfter a request for confirmation, the gauge will clear the readings fromBatch Menu (S). To clear another batch (T), repeat the procedure. To return the gaugeBatches (T). Reviewing an existing batch (ST)To review a particular batch use the up and down arrow soft keys andAs the Model S only has one batch, it isThe Elcometer 456 will then open up the Review Batch menu, allowing theY Review the statistics of the batch. Y Review the batch information, including. Y the date and time the batch was created. Y the batch type - normal, counted average or IMO PSPC. Y the probe type and serial number used to take the readings. Y the batch limits (if set). Y Review the batch’s calibration information, including. Y the date and time the batch was last calibrated or verified. Y the substrate type (or types if using an FNF probe). Y the probe type and serial number. Y the foil values used in the calibration. Y Review the individual readings.The Elcometer 456 displays. Y the readings in numerical order, the first reading is at the top. Y the substrate, time and date of measurement. Y icons indicating a reading above “ ” or below “ ” the limit. Y deleted readings icon “ ” is displayed if “Delete With Tag”Y Review a graph of the individual readings (T), see page 31.Up to five horizontal axes can be displayed representing different. Y Highest reading in the batch “ ”. Y Lowest reading in the batch “ ”Y Mean of readings in the batch “ ”Y High limit for the batch “ ”(when enabled). Y Low limit for the batch “ ”(when enabled). The readings are displayed as white or redIftherearemorereadingsinthebatchthancanbeWhen zoomed in, the graph will always displayPressing the c softkeySubsequent presses of the c softkey will scrollPressing the Zoom- softkey returns to the original overview graph ofToreturnthegaugetotheBatchReviewmenu,presstheBacksoftkey.To delete a particular batch’s individual readings only use the up andAfter a request for confirmation, the gauge will delete the selectedTo delete another batch, repeat the procedure, to return the gaugeThe user can delete all batches from the gauge by selecting. Exit Batching (ST). To stop using the Batching Mode and return to the Immediate mode. Batch Types (ST). When saving readings into a batch you have a choice of how theNormal: Each reading is saved into memory. The batch type can only be changed when creating a new batch. Counted Average: The average of a predefined number ofFor example a counted average ofLikewise the average of readings 4 - 6 are stored as the secondThe individual readings within the counted average (1.2.3,Average. The batch type can only be changed when creating a new batch.