eda m200 manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:eda m200 manual.pdf
Size: 3483 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 2 May 2019, 17:41 PM
Rating: 4.6/5 from 748 votes.
Status: AVAILABLE
Last checked: 12 Minutes ago!
In order to read or download eda m200 manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
eda m200 manualSerial port Com1, Com2 or Com3 As some software takes priority over the serial ports, it must be ensured that any such software has been terminated if using the same serial port as used by this software. 1.2 Fire Alarm Control Panel Requirements This programming software works for the Millennium range of control and booster panels including the: - EDA-M100 EDA-M150 EDA-M200 EDA-M300 EDA-M350. All versions of software fitted in panels are supported. 1.3 Additional Equipment Required In addition to the PC and control panel you will require a set of programming leads EDA-Q592. The leads can not be copied easily as a printed circuit board is fitted inside the 9 way D Type connector that plugs into the PC. 2.0 Introduction and Version Control This section details any changes to software and manuals for the Windmill programming software 3.0 Navigating the CD The supplied CD contains all the necessary set-up files for both Windmill and PanCom software. Also included on this disk are various other features, including product datasheets, manuals and photographs. Details on installing this software as well as accessing the other features included on the disk are detailed in the following section: 3.1 Disk Structure As can be seen the CD is made up of 7 main directories. The contents of each directory is detailed as fol- lows: datasheets: technical sheets for the EDA product range.Hardware Specification. In order to run Windmill or PanCom software the following system requirements must. Page 2 Page - 2 WindmillPage 3 Page - 3 Windmill. You will be prompted to change the disk at various stages but apart from this. Page 4 Page - 4 WindmillIn order to create a new. Page 5 Page - 5 Windmill. Device Type The device type of the unit installed. To ensure correct operation this value. Page 6 Page - 6 Windmill. Location text The location text cannot be changed on this screen and is displayed for. Page 7 Page - 7 Windmill. Radio Sounders Tone The tone for the radio sounder can be set.http://etonbio.com/newsLetters/images/cushcraft-atb-34-manual.xml
- Tags:
- eda m200 manual, eda m200 commissioning manual, eda m200 manual, eda m100 manual, eda m200 manual pdf, eda m200 manual transmission, eda m200 manual user, eda m200 manual download, eda m100 manual.
The default tone. Page 8 Page - 8 Windmill. Alert When Alert is pressed on the corresponding panel the sounder circuits, auxiliary relays and. Page 9 Page - 9 Windmill. Display Low Batteries NOT IMPLEMENTED. Timeout Values The system has many settings or operations, which. Page 10 Page - 10 Windmill. When downloading settings to the EDA-M200 panel, the options and messages must be performed sepa-. Page 11 Page - 11 Windmill. Since we want to download from a panel click 'Download from Panels'Simply select the location and click Save. Once you are happy with the save location. Page 13 Page - 13 Windmill. Providing the details shown are correct connect the PC to the module port of the. Page 14 Page - 14 Windmill. Data analysis is made up of three main stages:If the corrected line did not pass the validity checks or was altered by the. Page 16 Page - 16 Windmill. If this highest strength is below the standard 37 then two warning stars are displayed. Page 17 Page - 17 Windmill. Our example uses townhall files 1, 2 and 3. As stated these are selected by. Page 18 Page - 18 Windmill. Example M200 Download. At the heart of the MILLENNIUM system is a compact control panel designed around a 16-bit processor and featuring surface mount technology. 16 times more powerful than its predecessor and capable of supporting 3 times the number of devices, the panel benefits from well designed and clearly labelled operational features. Versatile software means that the millennium will interface readily with most other hardwired systems and is user friendly. Programming of devices can be carried out by either direct use of the internal keypad or via the PC interface. Excellent message quality is achieved as a result of a CCFL backlit 8 line liquid crystal display. As with all Electro- Detectors products, build quality is stringently controlled at every stage ensuring complete reliability of the system during operation. The fire alarm installed is a fully addressable radio system.http://www.atwoodgroup.ca/atwoodtechnology/userfiles/cushcraft-av-5-manual.xml Each device is individually identifiable by means of a unique unit number between 1 and 3000 inclusively. There is no wiring between units, control panels and sounders, the system communicating via short wave radio transmissions. No other radio equipment will interfere with the system and, likewise, the fire alarm will not interfere with any other radio equipment. For smaller installations a system has been designed to cater for 999 devices in twenty zones. The panel uses a smaller LED backlit 4 line liquid crystal display. This panel operates in a similar manner to other panels but has some sophisticated functions omitted. The operation of the system is dependant on the configuration, set by the commissioning engineer, but each installation is generally similar. When a smoke or heat detector detects an alarm condition or a break glass unit is operated, the relevant information will be displayed on the control panel. This includes the device location, unit number and zone of alarm. The sounders will operate. The situation should be investigated for the cause, and once under control the system can be silenced. Any subsequent alarm will operate the sounders once more and the relevant information for the new alarm being displayed on the screen. If the system detects any faults on any of the devices or the control panels e.g. mains fail or unit removal, a fault will be displayed. A buzzer will sound on the control panel to attract someone s attention. This can be silenced until the cause of the problem is corrected. For further operation of the system refer to the remaining sections of this manual. If you have any queries on the operation of the panel, please contact the company that maintains the system, printed on the reverse of this manual. If a particular option is not available, a suitable message will be displayed. 5 2 Basic Operation In order to operate the panel the front panel door will have to be unlocked.http://schlammatlas.de/en/node/21476 (Note: This section describes operation of a system with standard configuration. Operation is for the EDA-M100 and EDA-M150 unless otherwise stated) EDA-M100 and EDA-M150 EDA-M Normal When no faults or alarms are being displayed, the display will appear dark. The current time and date are displayed in area (3), not available on the EDA-200. The installing agents name and telephone number will be displayed in area (2). Whenever a radio message is received or transmitted the appropriate Rx or Tx box (1) will flash. Nothing will be displayed in area (4). The system Normal LED (6) will be illuminated. The mains supply light will be illuminated indicating the supply is healthy. 2.2 Fault When the panel detects a fault condition the internal buzzer will sound continuously and the common fault light will illuminate. The display back light will be switched on and the initial fault will be displayed on the first line, as shown in the example below. The display will detail the type of fault, which device and when it occurred. If programmed, a text location will be displayed below. The EDA-M200 is not capable of detailing dates and times for any of its events. Any subsequent faults will be displayed, and scroll through, on the bottom two lines of the display. The EDA-M200 will only display one fault at a time. Each fault is visible for a short period of time. Pressing the and keys will cause either the previous or the next fault to be displayed. This will then continue to scroll from the event being displayed. It is possible for 300 faults to be scrolled through. Area (3) will alternate between the total fault count and the date and time. The installing agents name and telephone number remains in area (2) of the display. In order to conserve power the LCD backlight will switch off 15 minutes after a fault occurs on any panel. If the mains supply is interrupted the fault will be indicated as above and the Mains Supply light will be extinguished.http://www.btrcontrols.com/images/carrier-air-conditioner-operation-manual.pdf For a complete list of faults see appendix. 6 The default fault relay is AUX 2 but may be reconfigured. All sounders will operate and the internal buzzer will sound. The display of the units in alarm is similar to that of the fault display. All alarms will override the fault display. The zone display (5) indicates the initial zone of alarm and the fire LEDs above the zone will flash. If another alarm condition occurs the zone display indicates the new zone momentarily and then reverts to initial zone of alarm. A new zone of fire is indicated by the internal buzzer pulsing for 2 seconds before returning to a continuous tone. The time and date location (3) displays a fault and alarm count, which indicates the number of alarms and faults presently on the system (not available on the EDA-M200). All zones that are in alarm are listed on the top middle portion of the display (2). For the EDA-M200 the top 2 lines contain the first zone of alarm, the last zone of alarm and the total number of zones in alarm. If a smoke detector only sends a single alarm message and does not follow up to complete the alarm verify then a pre alarm event is generated in the event log but not displayed. Rx Zones in Alarm 12:33:29 Tx Fire Zone 056 Callpoint: st Floor South Wing Fire Escape by Room 12 2 Evacuate Control: Ground Floor Main Entrance Behind Reception Example - Alarm Display for EDA-M100 and EDA-M150 7 1ST ZN LAST ZN TOTAL ZONE 04 HEAT 003 Second floor outside Example - Alarm Display for EDA-M200 Text Line scrolls across the LCD 2.4 Evacuate Pressing the evacuate button will operate the sounders, if they are not already sounding. This will override an intermittent sounding alarm. Evacuate will be displayed on the display along with the panel number where the button was pressed. The text location for this panel and the date and time is displayed. A buzzer on the control panel sounds continuously. By default the AUX relays 1 and 4 operate but may be redefined using the PC software. 2.5 Alert The alert function is designed as a warning. Pressing this button will cause the sounders to sound an intermittent tone. It will not override an evacuate or alarm tone, but will be displayed on the screen in a similar way to the Evacuate message. The buzzer sounds continuously whilst in this state. By default the AUX relay 2 operates but may be redefined using the PC software. 2.6 Silence If the system is in an alarm or alert state, from either a smoke detector, break glass or panel, pressing this button will silence the sounders. A message will appear on the screen indicating the operation is taking place. It can take several seconds for the complete system to silence. An internal buzzer will now sound intermittently. A subsequent alarm condition from a different unit or pressing either Evacuate or Alert will cause the sounders to re-sound. If a fault is being displayed operation of this button will silence the internal buzzer. Any subsequent faults will re sound the buzzer. In both of the above situations the silence LED above the button will be illuminated. The events remain on the screen. On the EDA-M200 the LED s are not fitted and the status is indicated on the top line of the LCD. In alarm the silence operation by default clears the sounder relays and AUX 4; the AUX mask may be reconfigured using the PC software. 2.7 Reset Once the system has been silenced, whether it be a fault or alarm condition, Reset will cause the system to return to normal. The reset button is disabled for six seconds after the silence has been pressed. The display will be cleared and a message will appear indicating the system is resetting. If the alarms or faults persist they will be redisplayed and actioned upon accordingly. If there were faults prior to an alarm condition reset will cause the faults to be re-displayed. In alarm the reset operation clears AUX 1 and 3 by default but may be reconfigured using the PC. In fault the reset operation clears AUX 2 by default, but will clear the relays programmed to operate on fault using the PC. Pressing Reset for 3 seconds in a system normal state will cause the lamps test function to operate. This will in turn flash all LED s and flash the LCD. 8 2.8 Print Momentarily pressing the print button will print earlier events in reverse order as previously displayed on the screen, starting with the most recent event first. When the required events have printed, a short press of the print button will cause the printing to cease. The print operation will terminate automatically once the entire log has been printed. A message appears on the LCD whilst the printer is finishing. This will take a few seconds as printing is terminated and the paper is fed out. To feed the paper through the printer press and hold the print button for the required amount of paper feed and then release the button. The printer is only available on the EDA-M150. If a printer is not fitted a suitable message will be displayed. 9 3.0 Advanced Operation This section details use of the menus and the functions available to a user. A password is required to perform these functions. The default user password for a newly supplied panel is If the password is forgotten an engineer will be required to gain access to the system to alter the user password. 3.1 Main Menu To enter the menu system press the button labelled menu. This function is disabled if the system is in an alarm condition. The display will prompt the user to enter a four digit password. There are five attempts to enter the correct password. If after five times the password is still not correct, the menu button will be disabled for thirty minutes. Once entered correctly the system will display momentarily that entry has been granted to a user and how many failed access attempts since the last entry. The main menu, detailed below, will now be displayed. If the menu system is entered and no keys are pressed for five minutes, which can be adjusted, the menu will cancel. All menus operate in the same basic manner. The highlighted bar can be moved up and down using the and keys. Pressing enter will then select this option. The scroll bar will wrap round the screen. For example, to select Change Options press the key until Change Options is highlighted and press Enter. Alternatively the number preceding the option can be pressed for fast access. On the M200 panel the menu bar is not featured and therefore the menu item must be selected using the numeric keys. To exit completely from the menus to the system display press cancel. To return to the previous menu press 0. Alarms will override the menu system. New faults will cause the buzzer to sound and the appropriate LED s illuminate but will not override the menu. The buzzer can be silenced by pressing silence. The faults will be displayed when the user exits the menu. For example, if some welding work was being performed that could possibly operate some detection units, then these units could be isolated. Both individual units and areas of detectors can be isolated through this menu. A pulsed panel buzzer is active while devices are isolated which can be silenced by pressing the Silence key while no faults or alarms are being displayed. Both Fault and alarm conditions are disabled through this function. When the system is set-up, a time limit is programmed to automatically re-enable any isolated devices or zones when the period has expired. A maximum of fifteen devices and fifteen zones can be isolated at any one time. Fifteen auxiliaries can also be isolated. The user is prompted to enter the unit number of the device to be disabled. Units 1 to 3000 can be disabled. A four digit number can be entered or a one, two or three digit number followed by enter. The unit number will be added to the isolated list of devices. All units except sounders and actuators can be isolated. To exit from this screen press cancel. Devices that do not exist on the system can not be isolated. On selecting this function a list of isolated devices is displayed, the first in the list being highlighted. To enable a device, use the and keys to select the unit to be enabled and press enter. This unit will now be enabled and will be omitted from the list. Isolate Zone This operates in the same way to the isolation of a detector. Zones 1 to 999 can be isolated. If a zone is isolated call points will still operate but transmitters, smoke and heat detectors will be isolated. Enable Zone Isolate Aux This operates in the same way to enable detector. The auxiliary relays on panels can be isolated. Either an individual panel can be isolated or all of the panels. The user is prompted to enter a two digit number relating to the panel number to be isolated. Entering 00 isolates all panels. A total of fifteen panels can be isolated at any one time. To enable the panels, press the or keys until the required panel to be enabled is highlighted and press enter. 11 Isolating and enabling devices, zones and auxiliaries on the EDA-M200 This is similar to the EDA-M100 and EDA-M150. Once the option is selected units and zones can be isolated and enabled on the same respective screen. Devices do not have to be logged to the system to be isolated. To isolate a device or zone select the appropriate option and enter the number followed by return. The isolated number will be displayed below. To isolate other numbers repeat the operation. To enable the zones or devices select the appropriate option and using the or keys position the cursor on the number to be enabled. Press enter to enable the number. The options are displayed below. All test modes will automatically re-enable themselves if more than 30 minutes elapses after the last activation. This value can be altered to a new setting by an engineer. The timeout setting is displayed on the menu screen. On the EDA-M200 the timeout is not labelled but is located in the bottom right of the screen. A pulsed panel buzzer is active while in test mode but can be silenced by pressing the Silence key while no faults or alarms are being displayed. To activate any of the test modes either highlight the option using the and keys and press enter or press the appropriate number. The new status will be displayed to the right hand side of the line. To enable the test modes Exit and save must be selected. Pressing cancel will not alter the test mode status. On the EDA-M200 options are selected by pressing the appropriate number. The test menu on the EDA-M200 is available as option 5 from the main menu. The default is off. This option allows the auxiliary relays on all panels to be isolated or enabled. The default is enabled. 12 Auto Silence With this option all sounders will silence automatically after 6 seconds. There will be a slight delay before all sounders silence. Zone of Alarm With this option enabled only sounders in the area of testing will operate. This can be used in conjunction with the auto silence option. 3.4 Change Options This function is not available on the EDA-M200 panel. Selection of this displays a sub-menu allowing the user to change the date, time and user password. The menu is shown below. Change Options 1. Change Date and Time 2. Change User Password 3. Change Language 0. Exit Use to highlight and press enter to select Date and Time User Password Language To change the date and time select option 1. Use the and keys to highlight the figure to be changed. Press enter to select the figure and it will start to flash. Use the or keys to change the value and press enter when finished. Once the date and time are correct select accept and press enter. Pressing cancel will exit without making any changes. To change the users password select option 2. The user will be prompted to enter the new password and then to re-enter the new password again. If the two passwords agree the password will be changed otherwise the old password will be reverted to. Passwords are at no point visible on the system. If the password is forgotten an engineer will have to be called to set a new password. Not implemented 3.5 View Event Log The event log is the history of all operations that have taken place on the system. The 300 most recent events are stored. The information displayed includes an event number, the event type, the device number, the location, the date and the time the event occurred. By selecting this menu the following sub-menu appears. This allows you to selectively view events. If an option is not available a message will be displayed. VIEW EVENT LOG 1. All Events 2. Test Events 3. Engineering Events 4. Real Events 5. Fault Events 0. Exit Use to highlight and press enter to select 13 Viewing the events, using any of the above options is essentially the same. Once selected the most recent event will be displayed as shown below. By using the or keys, the event log can be scrolled through to examine all events. If there is no event displayed with the event number then the end of the log has been reached. Pressing cancel will return to the menu. When viewing events other than all events some events may appear blank. These are events not relating to the search selected. View All Events 3 Low Battery Smoke Detector: st Floor South Wing Outside Room 12 2 Unit Removal Callpoint: Ground Floor Main Entrance Opposite Reception, Scroll, Cancel - Exit All events will be displayed including silence alarms, silence faults and resets. All Test Engineering Real All events will be displayed including silence alarms, silence faults and resets. Only events that were performed in a test mode will be displayed. Only events that were performed by an engineer will be displayed. Only real events will be displayed i.e. events that occurred whilst not in a test mode or an engineering mode. To view the event log on the EDA-M200 select the appropriate option. There are no options for viewing particular events. Fail Control XX Failure of main panel display Device Alarms Fire Zone XXX Smoke Det XXXX Fire Zone XXX Heat Det XXXX Fire Zone XXX Callpoint XXXX Fire Zone XXX Sounder XXXX Fire Zone XXX Wire Cct XXXX Fire Zone XXX External XXXX Fire Zone XXX Trans. XXXX Smoke detector fire event Heat detector fire event Callpoint fire event Sounder CP input fire event EDA400 wired interface fire event External wired interface fire event Transmitter fire event Device Faults Verify Fail Smoke Det XXXX Unit Removal Callpoint XXXX Batt 1 Low Sounder XXXX Batt 2 Low Sounder XXXX Batt Low Smoke Det XXXX Int. Fail Sounder XXXX OC Flt Callpoint XXXX SC Flt Trans.SYSTEM OPEN 17:30 01 Jan ENT 0 ESC Liquid Crystal Display. 6 Keypad. 7 Indicator Lights. 8 User Identification.PIN. ARMED Light is on when armed; off when disarmed; flashes to indicate a previous Unset system indications. Set System indication Programs 1, 2 and 3. Access codes. How to operate Personal Attack WARNING This manual contains information on limitations regarding product use and function The entire manual should be carefully User s Manual Getting Started. Page 2. Setting the Time of Day. Page 2 SETTING THE TIME Setting the Time of Day. Page 3 SETTING THE DATE Setting the Date. Page 4 EVENTS Programming Events. Pages Security System User's Guide Some terms widely used within The alarm panel is capable of extensive In the standby condition, the detectors will draw a low current, typically less than Some terms widely used within the industry are these: Arm and Disarm Your Quick Guider After getting this alarm system, you need to do the following Approved Document No. DFU2000510 Rev 1 DFU2000510 Rev 1 CONTENTS Important safety notes.3 Introduction.4 Fire alarm systems - an Fire Signal Receiving Board Description-4L. Fire Signal Receiving Board Description-8L. Reproductions The Active 5 is a microprocessor controlled intruder alarm panel. It features We understand the importance Should you have any questions or comments, please visit www.paradox.com and send The entire manual should be carefully The entire Paul, MN 55109 FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved DFU7001020 Rev 1 Operating Guide. Proudly Designed and Manufactured in New Zealand To use this website, you must agree to our Privacy Policy, including cookie policy. Please check your inbox, and if you can’t find it, check your spam folder to make sure it didn't end up there. Please also check your spam folder. Serial port Com1, Com2 or Com3 Also included on this disk are various other features, including product datasheets, manuals and photographs. Details on installing this software as well as accessing the other features included on the disk are detailed in the following section: The contents of each directory is detailed as follows: You will need to quit the set-up, un-install this older version: Simply insert disk 1, open the disk and contained in the folder disk 1 will be SETUP.EXE. Double click on SETUP to run the installation procedure. The screen will display blank panel and device information as shown in figure 5.2. To change the settings go to section 5.4 A screen allowing you to select a file from the disk as shown in figure 5.1 is displayed. To select the desired file double click on the file name. Data will load and a screen similar to Figure 5.2 will be displayed. To change settings proceed to section 5.4 A progress bar will be displayed as the data is loaded.The screen will display blank panel and device information as shown in figure 5.2. To change the settings go to section 5.4 A screen allowing you to select a file from the disk as shown in figure 5.1 is displayed. To select the desired file double click on the file name. Data will load and a screen similar to Figure 5.2 will be displayed. To change settings proceed to section 5.4 A progress bar will be displayed as the data is loaded. Care should be taken to establish that the cause and effects are the same for the system in all panels as individual panels may operate different relays in an alarm or fault condition.This option is not available for the module port at present. This screen may display information relating to the system being changed or be blank if it is a new system. This screen is used to only display the settings. Device information can be displayed by scrolling past the panel details. Panels 1 to 50 are displayed first. To scroll either click and hold on the scroll bar or drag the drag bar to the appropriate position. Use the scroll bar or drag bar to position to selector to the devices. Once positioned, double click on the parameter of the appropriate device to be changed. Figure 5.3 will be displayed. This will cause a screen as shown in figure 5.3 to be displayed. If the device number is not correct then the up and down arrows can be used to reposition the device number. It should be noted that any changes made prior to changing the device number will automatically be saved. To ensure correct operation this value must be correct. The codes follow the product code.In the global options the start and end time of this mode can be selected and the sensitivity changed during these hours can be selected. If devices are fitted in hostile areas or roof voids then the lower sensitivity should be set. This will be the device number displayed on the panel should the 2nd input detect an alarm condition. If not defined it will default to the next unit number provided the panel is put into the self learn mode. To ensure this operates correctly the unit should always be assigned if being used. It should be noted that any changes made prior to changing the device number will automatically be saved. Zone number The zone number cannot be changed on this screen and is displayed fore reference only. Initial Delay: Setting the initial delay will cause the system to display an alarm condition immediately and then delay for however many seconds set before operating any sounders or outputs. If any outputs or sounders are required to operate immediately in the event of an alarm condition, this value should be set to zero. The second delay can then be used to change the alarm operation after the delay period. In an alarm condition they can be programmed to switch 24V (On), pulse on for 1 second and off for 1 second (Int1), pulse on for 1 second and off for 2 seconds (Int2) or not to operate (Off). The appropriate option box should be selected for the appropriate sounder circuit. Relay Each main control panel is fitted with two auxiliary relays with the capability of being expanded to four with an EDA510 interface card. In an alarm condition for a device the relays can be individually programmed to operate (On) or not operate (Off). Care should be taken as by default the aux 2 relay is for common fault and is fail safe. If this is being used to signal an alarm condition the fault setting in the panel options must be amended. When wiring this relay always bare in mind the fail-safe operation. The relay is normally closed in normal operation and will open in either a fire condition or fault condition (depending on programming) or a power supply failure. Computer Hardware EDA-M200 Computer Hardware EDA-M200 Computer Hardware EDA-M200 Computer Hardware EDA-M200 Computer Hardware EDA-M200. Computer Hardware EDA-M200 Computer Hardware EDA-M200. Computer Hardware EDA-M200 Computer Hardware EDA-M200 user manual Computer Hardware EDA-M200 Computer Hardware EDA-M200 Computer Hardware EDA-M200 Computer Hardware EDA-M200. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with GD Commerce International Inc.