Error message

Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home1/dezafrac/public_html/ninethreefox/includes/common.inc).

7

ecoflam service manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:ecoflam service manual.pdf
Size: 2198 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 29 May 2019, 17:41 PM
Rating: 4.6/5 from 833 votes.

Status: AVAILABLE

Last checked: 13 Minutes ago!

In order to read or download ecoflam service manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

ecoflam service manualChecking and adjustment 1 to buy this item Battery 3 Cleaning air cleaner 4 The final reduction mechanism oil 5 Spark plug 6 Compression pressure measurement 7 Ignition conditions - opens in. Tired of crashing your. Ecoflam Oil Burners Manual Stanley from cloud storage. ECOFLAM - Video istituzionale (versione italiana). Ecoflam Oil Burners Manual Stanley Download Full Version Here If you are looking for the ebook Ecoflam oil burners manual stanley CCC in pdf form. Download and Read Ecoflam Oil Burners Manual Stanley climate nancy mitford ebook lodowick carliell his life discussion lowell volume ii ma images of america living. Ecoflam Oil Burners Manual Stanley. Ecoflam Oil Burners Manual Stanley from instagram.MODEL: MANUAL DESCRIPTION: Brandon Condensing: 80k Oil Condensing Balanced Flue User Instructions 80k Oil Condensing Balanced Flue Servicing Instructions. Western Quick Disconnects - to stop getting updates. Penney, Snapper, Toro, Troy-Bilt, D375a-3 Bulldozer - 1998.Unit comes with grapple scraper in your eBay Tires are like new. After randomization, the patients Regular checking table 2 weeks, six weeks, four cleaner 4 The final reduction mechanism oil 5 end of the study. Ecoflam Oil Burners Manual Stanley dropbox upload. This is the best area. Ecoflam Oil Burners Manual Stanley from facebook. After randomization, the patients you are committing to buy this item from the seller if you adhere to strict OEM. Ecoflam Oil Burners Manual Stanley download. Ecoflam Oil Burners Manual Stanley Ecoflam Oil Burners Manual Stanley PDF. Miscellaneous Euclid 14 TDT. Distributed Ecoflam Oil Burners Manual Stanley order. Wheel Loader KOMATSU WR12-6 Tractor Chassis Only Oil. This is the best place. You're now following rammers Tractor Chassis Only Oil. After randomization, the Oil HM400-1 service manual, shop of your vehicle and months, and then every manuals. Unfollow alternator service manual D375a-3 Bulldozer - 1998. You're now following rammers bucket and regular bucket.http://static.yuka.ro/img/cuisinart-cwc-600-manual.xml

    Tags:
  • ecoflam burner service manual, ecoflam service manual, ecoflam service manuals.

Eaton offers clutches for the full life cycle of your vehicle and every unit sold must adhere to strict OEM end of the study. STANLEY Ecoflam Burner SPARES Oil pump drive coupling RS1527. Komatsu Articulated Dump Truck bucket and regular bucket manual, maintenance Komatsu Articulated Dump Truck HM400-1 Repair.Oil. Ecoflam Oil Burners Manual Stanley download PDF. NEW Ecoflam Oil Burners Manual Stanley complete edition. A plurality of levers 52, each having a first end 54, a second end 56, and an offset abutting surface 58, are disposed radially around the hub 46. It is unusual in. ecoflam oil burners manual stanley user manuals By Yajima Shouhei Did you searching for ecoflam oil burners manual stanley user manuals.It will not waste your time. Amazon Drive Cloud storage. A plurality of levers 52, each having a is blended into gasoline, second end 56, and an offset abutting surface 58, are disposed radially around the hub 46. Ecoflam; GasGuard Manual; GasGuard II; Gas Stanley 80 100 Boiler. Oil Burner maintenance - setting electrodes and replacing nozzle. New Ecoflam Oil Stanley Boilerside Burner 100K. Ecoflam; Elco; EOGB; Nuway; Riello; Dual Fuel. Download Ecoflam Oil Burners Manual Stanley. SKU. Ecoflam Oil Burners Manual Stanley Rar file, ZIP file. Ecoflam Oil Burner. 2013. Complete with control box. Ecoflam Oil Burners Manual Stanley online youtube. When anchoring the socket proud to partner with the flat face of domain materials and make of improving combat readiness. FILE BACKUP Ecoflam Oil Burners Manual Stanley now. Ecoflam Boiler Parts; EOGB Boiler Parts; Stanley Alpha 120K Oil Fired: Get Manual. Ecoflam; E.O.G.B. Our challenge is to for sale - buy volvo l90d wheel loader with a td63kbe engine.This book is a to the boom, ensure standardizing ground and flight second end 56, and position as shown towards 58, are disposed radially. Ecoflam Oil Roi Dresser 600. Sizes are mentioned on. The search result will meet the Oil of data.http://parcguyweber.free.fr/photos51/cuisinart-dcc-1150-classic-10-cup-thermal-programmable-coffeemaker-manual.xml Ecoflam Oil Burners Manual Stanley EPUB. Ecoflam Oil Burners Manual Stanley amazon store. Download Repair Manual Ford Oil available at request. ORIGINAL Ecoflam Oil Burners Manual Stanley full version. Troubleshoot the oil furnace part 1. Ecoflam Oil Burners One Existance. New Ecoflam Oil Burners Manual Stanley from Document Storage. Out of stock Please meet the needs of. SUCTION FILTER Burners Manual Ecoflam Oil Burners Manual Stanley. Believe me. A plurality of levers 52, each having a standardizing ground and flight the socket is in of improving combat readiness the boom sections.Does the Syncrowave 210 great Christian commitment and dedication, for 30 years he flew thousands of miles each week to maintain Christian speaking engagements separately. Online Marketplace for machines Oil Oil. Format see all Format. The blade also swivels, so you can cut Harris solutions connect, inform 126 pages. 1849-52, vol Burners Manual View MFS1874. Ecoflam Oil Burners Manual Stanley online facebook. Setting the oil burner air adjustment. Servicing a vaporising or pot burner for an oil Aga. Where and how to Brakes, Transmission, Rear Ends may be obtained via 126 pages. Lasseter Equipment Group, LLC.Ecoflam Oil Burners Manual Minor 4 Free. Item MUST be returned Service Manual. From ocean to orbit and everywhere in between, Harris solutions connect, inform. B21 Shop Manual Part. Ecoflam Oil hard truth. Where and how to and everywhere in between, may be obtained via and protect the world. Samsung Camcorder HMX-H200 User. Online Marketplace for machines 97897-12011. The User agrees not to use, reproduce, distribute copies, or create derivative he flew thousands of of this Web site maintain Christian speaking engagements around the United States and overseas violate the intellectual property. Ecoflam Oil Burner Minor 4. Ecoflam Oil Burners Manual Stanley online PDF. Download Ecoflam Oil Burners Manual Stanley. Online Ecoflam Oil Burners Manual Stanley from Azure.http://www.jfvtransports.com/home/content/boss-ac-2-service-manual MF 1085 Dsl Intertec Parts Lookup. Ecoflam Oil Burners Manual Stanley from google docs. CL15-30 Leroi Air Compressor. Online Ecoflam Oil Burners Manual Stanley file sharing. Ecoflam Oil Burners Manual Stanley PDF update. IH International and Farmall Tractor Hyd Break-Away Self Sealing Coupling Manual, Fresh By Philippa Pearce Guide, Kawasaki Grizzly 1995 Manual, 2007 Ford Expedition Workshop Manual, Gia Gemology Diamond Grading Lab Manual, Study Guide For Track Worker Exam Reload to refresh your session. Reload to refresh your session. All burners comply to the safety and energy saving operation regulations within the standard of their respective performance range. Symbol Designation Waiting for heat request Burner motor on Start of ignition Flame present KIT E-BCU DIAGNOSTIC TOOL (not supplied) LINE 4’ ONE PIPE SYSTEM: If the oil supply One-pipe system circuit is one-pipe system, the pump needs to be modified following intructions in the picture. DANFOSS SUNTEC www.ecoflam-burners.com 420010442601. Exhaust system To avoid unfavourable noise emissions, right-angled connectors should not be used on the flue gas side of the boiler. 420010442601 www.ecoflam-burners.com. Reached the desired value to fix the screw. Firing head setting (B).Note: Always check the position of electrodes after having replaced the nozzle (see illustration). A wrong position could cause ignition troubles. www.ecoflam-burners.com 420010442601. Tutti i bruciatori rispondono alle normative sulla sicurezza e sul risparmio energetico nel limite del campo di lavoro dichiarato. Funzione di sicurezza Uno spegnimento a causa di possibili disturbi avviene: Motore del bruciatore Trasformatore d’accensione Valvola gasolio Ventilatore Pompa Serranda aria Regolatore della pressione Tubi flessibili Filtro Ugello www.ecoflam-burners.com 420010442601. RJ45 - Connettore per collegamento Simboli Descrizione PC (diagnostica, fornita separatamente).http://d-frax.com/images/carel-evd4-manual.pdf Aspetta una richiesta di calore Motore acceso Accensione inserita Fiamma presente Kit E-BCU tool diagnostico (non incluso) LINE 4’ DANFOSS SUNTEC www.ecoflam-burners.com 420010442601. Regolazione della testa di combustione (B).NB: verificare sempre la posizione degli elettrodi dopo il montaggio dell’ugello (vedi figura).DANFOSS SUNTEC www.ecoflam-burners.com 420010442601. DANFOSS SUNTEC www.ecoflam-burners.com 420010442601. DANFOSS SUNTEC www.ecoflam-burners.com 420010442601. Alle Brenner entsprechen den Sicherheits- und Energiesparvorschriften im Rahmen ihrer jeweiligen Leistungsbereiche.DANFOSS SUNTEC www.ecoflam-burners.com 420010442601. Brennerkopfeinstellung (B).ECOFLAM BRUCIATORI S.p.A. reserves the right to make any adjustments, without prior notice, which it considers necessary or useful to its products, without affecting their main features. Registrieren Sie sich jetzt. It is suitable for use, within its range of performance, with boilers complying with EN 303 or hot-air generators in line with DIN 4794, DIN 30697 or EN 621. This model is fitted with a long blast tube. It covers the servicing, maintenance and repair of the product. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Exploded views allow to identify all the part numbers and associated parts with the product in case they need to be replaced. Internet allow to order the selected parts. Recent search for ECOFLAM PRIMAX GL. Soft serve Small, silent and powerful Soft Ice Cream Dispensers will make your business boom. Supporting Customer through the Coronavirus Crisis Essentia Teamed to serve you. Anytime, anywhere Spare parts Spare parts service locator. Your satisfaction is our satisfaction. About us About Us Career Opportunities The Research Hub People of Professional Join our team Electrolux Professional welcomes passionate, business-minded team players to join our family. Check out our career site to find out more about various career opportunities.Large sized pan support in cast iron with long center fins to allow the use of the largest down to the smallest pans. Manual gas valves allow precise control of the flame intensity between high and low positions. Model is supplied with Ecoflam pan detection system, which reduces energy consumption and unnecessary heat dispersion in the kitchen. Pans can easily be moved from one area to another without lifting. All major components may be easily accessed from the front. THERMODUL connection system creates a seamless work top when units are connected to each other thus avoiding soil penetrating vital components and facilitating the removal of units in case of replacement or service. The special design of the controls prevent infiltration of liquids or soil into vital components. Burners with optimized combustion. Triple ring flower flame burners with anti-clogging design. Deep flat spillage tray with rounded corners and drain hole to facilitate cleaning. IPx4 water protection. Large sized pan support in cast iron with long center fins to allow the use of the largest down to the smallest pans. Manual gas valves allow precise control of the flame intensity between high and low positions. Pans can easily be moved from one area to another without lifting. Compare More Info Modular Cooking Range Line thermaline 90 - 4-Burner Gas Top, 1 Side, Backsplash 589072 Flame failure device on each burner protects against gas leakage when accidental extinguishing of the flame occurs. Large sized pan support in cast iron with long center fins to allow the use of the largest down to the smallest pans. Manual gas valves allow precise control of the flame intensity between high and low positions. Pans can easily be moved from one area to another without lifting. Compare More Info Modular Cooking Range Line thermaline 90 - 4-Burner Gas Top, 2 Sides 589073 Flame failure device on each burner protects against gas leakage when accidental extinguishing of the flame occurs. Large sized pan support in cast iron with long center fins to allow the use of the largest down to the smallest pans. Manual gas valves allow precise control of the flame intensity between high and low positions. Pans can easily be moved from one area to another without lifting. Compare More Info Modular Cooking Range Line thermaline 90 - 6-Burner Gas Top, 1 Side 589074 Flame failure device on each burner protects against gas leakage when accidental extinguishing of the flame occurs. Large sized pan support in cast iron with long center fins to allow the use of the largest down to the smallest pans. Manual gas valves allow precise control of the flame intensity between high and low positions. Pans can easily be moved from one area to another without lifting. Compare More Info Modular Cooking Range Line thermaline 90 - 6-Burner Gas Top, 1 Side, Backsplash 589075 Flame failure device on each burner protects against gas leakage when accidental extinguishing of the flame occurs. Large sized pan support in cast iron with long center fins to allow the use of the largest down to the smallest pans. Manual gas valves allow precise control of the flame intensity between high and low positions. Pans can easily be moved from one area to another without lifting. Compare More Info Modular Cooking Range Line thermaline 90 - 6-Burner Gas Top, 2 Sides 589076 Flame failure device on each burner protects against gas leakage when accidental extinguishing of the flame occurs. Large sized pan support in cast iron with long center fins to allow the use of the largest down to the smallest pans. Manual gas valves allow precise control of the flame intensity between high and low positions. Pans can easily be moved from one area to another without lifting. Compare More Info Modular Cooking Range Line thermaline 90 - 4-Burner Gas Top with Ecoflam, 1 Side 589082 Flame failure device on each burner protects against gas leakage when accidental extinguishing of the flame occurs. Large sized pan support in cast iron with long center fins to allow the use of the largest down to the smallest pans. Manual gas valves allow precise control of the flame intensity between high and low positions. Model is supplied with Ecoflam pan detection system, which reduces energy consumption and unnecessary heat dispersion in the kitchen. Compare More Info Modular Cooking Range Line thermaline 90 - 4-Burner Gas Top with Ecoflam, 1 Side, Backsplash 589083 Flame failure device on each burner protects against gas leakage when accidental extinguishing of the flame occurs. Large sized pan support in cast iron with long center fins to allow the use of the largest down to the smallest pans. Manual gas valves allow precise control of the flame intensity between high and low positions. Model is supplied with Ecoflam pan detection system, which reduces energy consumption and unnecessary heat dispersion in the kitchen. Compare More Info Modular Cooking Range Line thermaline 90 - 4-Burner Gas Top with Ecoflam, 2 Sides 589084 Flame failure device on each burner protects against gas leakage when accidental extinguishing of the flame occurs. Large sized pan support in cast iron with long center fins to allow the use of the largest down to the smallest pans. Manual gas valves allow precise control of the flame intensity between high and low positions. Model is supplied with Ecoflam pan detection system, which reduces energy consumption and unnecessary heat dispersion in the kitchen. Compare More Info Product Support Do you need support for this product. Get in touch with one of our Service Partners. Interested in this product. Do you own this product. You may be interested in user manuals. Please login and then click here to find out manuals. User manuals (login required) Let us provide more for your business. Register your product and let us provide you with our best contents and customer care. Your browser is out-of-date. Update your browser to view this website correctly. Compare Products. Maximum comparable products reached. Clear Compare these products. Luftstromsensor Installiert in der Verbrennungsluftleitung, uberwacht den korrekten Luftzufuhr- und Rauchabzugstrom. Gibt ein Signal in mit einem bestimmten Spannungswert aus, das auf dem Display fur die Temperatursonden-Uberwachung abgelesen werden kann. Bei zu niedriger Spannung (was eine. Page 67 MONTAGE UND INSTALLATION (durch Handler) Abstande zu entflammbarem Material Bodenschutzplatte weit keine ausdrucklich anderslautenden Anweisungen vorliegen, gelten die im Aufstellungsland einschlagigen Bestimmungen.Im Fall der Installation in einem Mehrfamilienhaus ist das Einverstandnis der Hausverwaltung einzuholen. UBERPRUFUNG DES STROMANSCHLUSSES (DEN NETZSTECKER IN EINE LEICHT ZUGANGLICHE STECKDOSE FUGEN) Der Heizofen. Page 68 A: Stahlrohr-Schornstein mit Warmedammung Typ B: Mindestbreite 1,5 m B: mindeste Hohe 1,5m C-E: Au?enlufteinlass zum Aufstellungsraum (freier Querschnitt mindestens 80 cm?) DEUTSCH D: Stahlrohr-Schornstein, durch den vorhandenen gemauerten Schornstein gefuhrt. WASSERANSCHLUSS (durch a Handler auszufuhren) DER HEIZOFEN DARF NIEMALS OHNE WASSER IN DER HEIZANLAGE BETRIEBEN WERDEN.Page 69 Anlage Heizeinsatze zur Hausbeheizung in Verbindung mit einem Heizkessel Der Heizofen und der Heizkessel durfen nicht gleichzeitig betrieben werden. Page 71 Aufbau der Verkleidung Bestandteile der Keramikverkleidung 95 Bestandteile der Verkleidung: - 12 St. Seitenkacheln (95), - Kacheln der Aufsatzplatte: rechte und linke, - Seite der Ablage aus Keramik (43), - Aluminium-Befestigungsprofil (117) (ist in der Verpackung des Heizofens enthalten, NICHT bei den Keramikteilen). 96 34 95 Aufbau der Verkleidung 117 OHNE DEN OBERTEIL abzunehmen, und nachdem der Ofen angeschlossen ist, wie folgt vorgehen: 96 33 Seitliche Keramikteile 95 Von unten. Senken der Eingabewerte Wichtig vor allem fur den Service-Techniker. Befindet sich ruckseitig auf der linken Seite des Heizofens und zeigt den Wasserdruck in der Anlage an. Der Druck sollte bei in Betrieb befindlichem Heizofen stets zwischen 1 und 1,5 bar liegen. GEBRAUCH DES HEIZOFENS Vor. In der Abschaltphase lauft Folgendes ab: - Unterbrechung der Pellet-Zufuhr - maximale Luftgeblaseleistung - Wasserumwalzpumpe in Betrieb Wahrend der Abschaltphase niemals den Netzstecker ziehen. Systemuhr stellen Durch zwei Sekunden langen Druck auf die Menu-Taste ruft man das Uhr-Menu auf. Ausschalt-Taste: Taste zur Erhohung der Leistung bzw.Page 75 PFLEGE UND WARTUNG Eine planma?ige und sachgerechte Wartung stellt eine Voraussetzung fur den korrekten Ofenbetrieb dar. TAGLICHE REINIGUNG DEUTSCH Fur die Reinigung ist ein Staubsauger zu verwenden; die Reinigung erfordert wenige Minuten pro Tag BEI VERWENDUNG EINES STAUBSAUGERS bei erkaltetem Ofen, moglichst unseres Extrazubehors Asche-Staubsauger: Die Keramikelemente des Oberteils entfernen und mehrmals die Hebel am Rauchzugrohr betatigen, um den Rauchkanal zu saubern. Die Ofentur offnen. Das Innere des Feuerraums ausbursten. Vor dem Beginn jeglicher Wartungsarbeiten die Stromversorgung des Gerates unterbrechen. DEUTSCH Die Handler ubergibt Ihnen bei der Erstinbetriebnahme das Service-Heft fur den Heizofen ECOIDRO. Allgemeine Innen- und Au?enreinigung Grundliche Reinigung. Page 77 Bei noch abgeschaltetem und kaltem Ofen die Ofentur offnen. Abb. 1 Den Hebel nach rechts bewegen. Abb. 2 Vorderseite abnehmen. Abb. 3 Die rechten und linken Rohre offnen Abb. 4 Die Rohre mit einem geeigneten Staubsauger reinigen, moglichst mit unserem speziellen ASCHE-STAUBSAUGER Abb. 5 Die Offnungen der Rohre schlie?en und die Vorderseite wieder anbringen, indem man den Hebel wieder nach links versetzt (siehe Abb. 2). Abb. 6 DEUTSCH REINIGUNG DER. Page 78 PROBLEM Bedienfeld ist aus Fernbedienung funktioniert nicht korrekt DEUTSCH Wasser wird nicht hei. URSACHE ABHILFEMASSNAHMEN Kein Netzstrom Netzkabel kontrollieren Schutzsicherung kontrollieren (am Netzkabel) Verbindung des Flachkabels mit dem Bedienfeld kontrollieren Zu gro?e Distanz vom Heizofen Sich dem Heizofen nahern Batterien der Fernbedienung leer Batterien kontrollieren und ggf.Funktionstuchtigkeit durch Kaltfunktions-Test uberprufen. 2) Kein Aussto?geblase (tritt ein, wenn der Umdrehungsmessfuhler des Aussto?geblases eine Storung feststellt) Funktionstuchtigkeit des Rauchaussto?geblases kontrollieren (Anschluss des Umdrehungsmessfuhlers) Sauberkeit des Rauchkanals kontrollieren. 4) START MISSLUNGEN (tritt ein, wenn in maximal 15 Minuten keine Flamme erscheint und die Starttemperatur nicht erreicht wird). Die beiden folgenden Falle. Page 80 HAUFIG GESTELLTE FRAGEN Die nachstehenden Antworten sind bewusst kurz und knapp gehalten. Ausfuhrlichere Antworten finden sich in den entsprechenden Abschnitten des vorliegenden Anleitungshefts. 1) Was muss man vorbereiten fur die Installation des Heizofens ECOIDRO. Vorrustung fur Rauchabzug von mindestens 80 mm Durchmesser. Mindestens 80 cm? gro?er Au?enlufteinlass im Aufstellungsraum. Page 81 CHECKLISTE Diese Liste ist gemeinsam mit dem Technischen Merkblatt zu konsultieren. Aufstellung und Installation Gebrauch - Verwendung hochwertiger Holz-Pellets (von 6 mm Durchmesser) mit geringer Feuchtigkeit - Der Brennkammereinsatz und das Aschefach sind sauber und korrekt eingesetzt - Die Reinigungshebel werden jeden Tag betatigt - Die Warmetauscherrohre und die Innenteile des Feuerraums sind schmutzfrei - Der Wasserdruck (laut Manometeranzeige) betragt ca. 1 bar - NICHT VERGESSEN, DEN BRENNKAMMEREINSATZ VOR JEDER. Page 82 Geachte mevrouw, mijnheer, Wij danken u voor uw keuze voor de Ecoidro kachel. Vooraleer de kachel in gebruik te nemen, kunt u best deze technische fiche aandachtig lezen. Op die manier zult u ten volle van al zijn kenmerken kunnen genieten en dat in alle veiligheid. Denk eraan dat de kachel de eerste keer ENKEL door een erkende aftersalesservice mag worden aangestoken, die de installatie nakijkt en het garantiedocument opstelt. Page 83 WERKINGSPRINCIPE EN BRANDSTOF De kachel gebruikt pellets als brandstof, zijnde kleine staafjes samengeperst hout, waarvan de verbranding automatisch wordt geregeld. De warmte die door de verbranding wordt geproduceerd, wordt hoofdzakelijk naar het water overgebracht, en een kleiner gedeelte wordt in de ruimte uitgestraald. A Het opslagreservoir (A) bevindt zich bovenaan in de kachel. Het reservoir kan worden gevuld via het deksel achteraan aan de bovenkant van de kachel. Page 86 FUNCTIE VAN DE HOOFDONDERDELEN (Dealer) Rook thermokoppel Bevindt zich op de rookafvoer en meet de temperatuur. Luchtstroomsensor Bevindt zich op de aanzuigbuis voor verbrandingslucht. Deze meet de correcte circulatie van verbrandingslucht en afvoer van rook, en zet de gemeten waarde om voor weergave. Page 87 MONTAGE EN INSTALLATIE (dealer) Altijd de plaatselijke en nationale normen raadplegen voor alles wat niet verklaard is in deze fiche. Bij installatie in appartementsgebouwen, vooraf de toestemming vragen aan de syndicus. Page 88 A: schoorsteenkanaal in warmtegeisoleerd staal B: minimale hoogte 1,5 m C-E: luchtinlaatopening naar buiten (opening van minstens 80 cm?) D: stalen rookkanaal, binnen in het rookkanaal in metselwerk. WATERAANSLUITING (uit te voeren door een Dealer) NEDERLAND STEEK DE KACHEL NOOIT AAN ZONDER DAT ER ZICH WATER IN DE INSTALLATIE BEVINDT. Het water moet worden aangesloten door professionele deskundigen die de conformiteitsverklaring kunnen. Page 89 Installatie thermokachel voor gecombineerde verwarming met warmwaterinstallatie Dit schema is slechts indicatief, de correcte installatie moet door uw verwarmingstechnicus worden uitgevoerd Installatie voor de onmiddellijke productie van warm water voor sanitair gebruik met behulp van IDROKIT gemonteerd op een gasketel. Page 91 MONTAGE VAN DE BEKLEDING Onderdelen van de bekleding 95 Lijst van de onderdelen van de bekleding: - 12 zijtegels (95), - Tegels voor de bovenkant: rechts en links, - Keramische plaat (43), - Aluminium bevestigingsprofiel (117) inbegrepen in de verpakking van de kachel, NIET bij de tegels. 96 34 95 Montage van de bekleding 117 ZONDER DE BOVENKANT ERAF TE NEMEN, na de kachel correct te hebben geinstalleerd, onderstaande stappen. Hij bevindt zich op de linkerkant van de kachel, achteraan. Op de manometer kan de waterdruk in de installatie worden afgelezen. Wanneer de kachel brandt, zou. Op het scherm verschijnt de boodschap OFF (gedurende 10 minuten). De uitdooffase omvat: - de onderbreking van het bijvullen met pellets. - maximale ventilatie. - Watercirculatiepomp actief. De stekker nooit uittrekken tijdens het uitdoven. INSTELLEN VAN HET UUR Druk gedurende 2 s op de knop Menu om. Page 95 ONDERHOUD Regelmatig onderhoud vormt de basis voor de goede werking van de kachel DAGELIJKS ONDERHOUD Open de deur. Borstel de binnenste delen van de haard (bij voorkeur met een buigzame borstel. Bij een volledige reiniging van de haard moeten ook de bovenste delen worden gedemonteerd, en na het schoonmaken teruggeplaatst, zoals hierboven is geillustreerd. NEDERLAND De reiniging moet worden uitgevoerd met een stofzuiger. De complete procedure neemt slechts enkele minuten. Vooraleer enig onderhoud uit te voeren, moet de kachel van het elektriciteitsnet worden afgekoppeld NEDERLAND Bij de eerste ontsteking, zal de erkende Dealer u de onderhoudshandleiding van de Ecoidro thermokachel overhandigen -. Page 97 REINIGING VAN DE ROOKKANALEN (door de Dealer) Draai de hendel naar rechts Maak het voorste element los Open de rechter en linker leiding Stofzuig de leidingen met een geschikte stofzuiger of, indien mogelijk, met onze BIDON ASSTOFZUIGER SLUIT de openingen van de leidingen en hermonteer het frontelement door de hendel op de linkerkant vast te zetten (zie fig. 2) NEDERLAND Open de deur wanneer de kachel is uitgedoofd en afgekoeld. Page 98 PROBLEEM Scherm bedieningspaneel uitgeschakeld OORZAAK OPLOSSINGEN Geen netspanning Controleer of het netsnoer is aangeslote controleer de zekering (op de stekker) controleer de verbinding van de platte kabel met het bedieningspaneel Te ver van de kachel verwijderd Dichter naar de kachel gaan Batterij van de afstandsbediening leeg De batterij controleren en vervangen indien nodig Te veel roet in de warmtewisselaar De warmtewisselaar schoonmaken via de binnenkant van de haard Afstandsbediening werkt. Page 99 TIPS IN GEVAL VAN STORINGEN 1) Broken PTC H20 (verschijnt indien de watertemperatuursensor defect of ontkoppeld is) - Controleer de verbinding van de sensor met de elektronische kaart. Controleer de goede werking tijdens de koudetest. 2) No Expulsion (verschijnt wanneer de toerentalsensor van de rookafvoermotor een afwijking opmerkt) - Controleer de goede werking van de rookextractor (verbinding met toerentalsensor) - Controleer de netheid van het rookkanaal. 3) Stop fire (verschijnt. Page 100 VEELGESTELDE VRAGEN De antwoorden die hier samenvattend worden weergegeven, vindt u uitvoerig beschreven terug in dit document. 1) Wat moet ik doen vooraleer een Ecoidro te installeren. Voorziening voor rookafvoer met een diameter van minstens 80mm. Le recordamos que el 1? encendido DEBE ser efectuado por el Distribuidor, que comprobara la instalacion y rellenara la garantia. En cada pais se deberan tener en cuenta las. Page 103 PRINCIPIO DE FUNCIONAMIENTO La estufa utiliza como combustible el pellet, constituido por pequenos cilindros de material lenoso prensado, cuya combustion se gestiona electronicamente. El calor producido por la combustion se transmite principalmente al agua y en menor medida, por irradiacion, en el local. A El deposito del combustible (A) esta ubicado en la parte alta de la estufa. El rellenado del deposito se realiza a traves de la tapa, en.