doorking 1810 manual pdf
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:doorking 1810 manual pdf.pdf
Size: 2494 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 5 May 2019, 22:33 PM
Rating: 4.6/5 from 663 votes.
Status: AVAILABLE
Last checked: 10 Minutes ago!
In order to read or download doorking 1810 manual pdf ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
doorking 1810 manual pdfYou must have JavaScript enabled in your browser to utilize the functionality of this website. Managers can easily create and change the directory as needed with a word processing program (templates are available from DoorKing). The 1810 is available in both surface and flush mount styles. Visitors are identified by voice communication via the telephone.No phone lines or internet cables to run - no trenching or conduits to install. And, of course, DKS telephone entry systems are all compatible with the traditional POTS copper wire. Replaced a forty year old system that was starting the show it's age. Previous system allowed for only one area code for programming. This system allows up to 15 area codes. Which helps now that everyone has a cell phone with all different area codes. I also like the built-in paper directory. It allows for faster tenant lookup without having to scroll through a long list on the LCD screen. It also allows for remote programming by a touch tone phone. Something my other system was lacking. Well laid out instructions made for a very fast install. About an hour including new mounting plate on existing kiosk.Please, log in or register You can simply remove the item from your cart. You have no obligation to purchase the product once you know the price. You can simply remove the item from your cart. You must have JavaScript enabled in your browser to utilize the functionality of this website. Each Access Plus Series unit allows Voice and Data connection over either Cellular, VoIP, Wireless, or POTS. DKS offers easy ways to connect fast using the DKS IM Server and DKS Cellular services. With the easy to use Access Plus Account Manager programming software, you can customize the system immediately. Set up time zones, add or delete access codes, set up email notifications, and even lock or un-lock a door with the click of the mouse button.http://schoolinglog.com/sawaree/sources/userfiles/test1/Uimages/canon-ir-3750-service-manual.xml
- Tags:
- doorking 1810 manual pdf, doorking 1810 manual pdf, doorking 1810 manual pdf free, doorking 1810 manual pdf file, doorking 1810 manual pdf online, doorking 1810 manual pdf converter, doorking 1810 manual pdf maker, doorking 1810 manual pdf software, doorking 1810 manual pdf downloads, doorking 1810 manual pdf manual.
It features a built-in lighted directory that can be printed directly from the Access Plus Account Manager software. If Microsoft discontinues their support iof the downgrade DLL, we will discontinue support of Windows XP. Please, log in or register You can simply remove the item from your cart. SuMoD te UC GPre toIf Liss C. N umSBu ne is e NTr n Bu umEn ga an esToMoBern s J CODE. Broward EMoBrow SBrow JBrya KByro WByan RDan BDaw RDeL JDillDixo MDom DDonDon PDon KDom DDonDon PDon KHird KHitcHodHoo AJens HJohn DJohn MJone TJone ALuci BMan BMas GMas DMoz FMuc JMul JNab BNab KNeu JRay ASch ASeel r SSelle JSha HSha RSim DSmi LSom JStee HStol FSynWya FCircuit Board. Serial NumberPhone Number. Leave Manual with Owner. Download ACCESS PLUS ACCOUNT MANAGER Software FREE at:All rights reserved. UL Listed. Copyright 2009 DoorKing, Inc. All rights reserved. Phone InWireless. Adapter. Phone OutEmergency. Entry Switch. Back-Up. Battery Power. Relay 1Relay 2Input PowerPhone In (Positive - Tip). Ground (Required). Phone Out (Positive - Tip). Phone Out (Negative - Ring). Not Used.WARNING MaximumBATT CHARGE LED: WhenONLY used withTelephone. InterfaceSee section 1.9.ConnectorGain AdjustVolume. AdjustBAD DNS - Yellow LED indicates an email server problem, rejecting the mail server. LAN DOWN - Red LED indicates a problem with the LAN. IP or Gateway (router) down or wrong gateway IP address. PHONE LINE IN USE - Yellow LED indicates that the phone line is being used (dial-out, call forwarding, etc.). LAN CONNECTION - Green LED indicates that the wire connection from the unit to the computer or router is good. SW2 - Termination Switch - Only used when RS-485 access control devices are being used (See section 1.11.1).Program from System Keypad ONLY. Quick Reference Table. Section 2.1 Programming Master Code. Program a Master CodeCode Button. NO Master Code. Programmed. Set the Unit’s IP Address (reboot required)Single or Double Ring (1816 Interface ONLY)Talk TimeRelay Strike Time.http://phillipsseafoodllc.com/userfiles/canon-ir-4750-manual.xml Tone Open NumbersSection 2.3 Programming Network Setup for a ComputerRelay 1: 9 8 7 6. Relay 2: 5 4 3 2. Relays 3-8 Not SetDelete an Access Code (Simple or Time Zone Restricted)Time and Date Calendar Chip ProgrammingAutomatic Relay Activation Time Zone Programming (Up to 4 zones). Access Code Time Zone Programming (Up to 4 zones)Section 2.5 Directory Codes. Empty. Section 2.6 Access Codes for Access Control Devices. Section 2.7 Time Functions. Section 2.8 Miscellaneous. Restore Factory SettingsThis allows ALL of the. Access Plus manuals to remain in sync with each other when referencing programming numbers.Both Boards Together - 1970-010No additional monthly expense for a second telephone line (whenPlus telephone interface). Order part number 1812-082. Included with the system is an extra random keyed cabinet lock. If desired, for added security againstNote: DoorKing cannot replace this specific lock or keys if lost.D te UC GPre o d eIf Liss C. N u mSBu ne is e NTr n Bu umEn ga an esToPreesse CoHa deEnnte ng-Up Nu er OnDirAdaAkin J. Dis. BuAnnPreTon. And e J. AnBroBro TBro SBro JBrya KByro WBya RCor RCou DCraiDalt GDan BDaw RDeL JDill e MDixo MDon KCa nBrokBros TBrow SBrow JBrya KByro WByan RFarr FFern MGar ez SGen JGon MHab z HHam ld AHenJon ACraiDalt GDan BDaw RDeL JDillDixo MDom DDonDon KFern MGarfGarr SGen JGon MHab z HHam ld AHenHird KJone AKlein nLamLand BLang SLeviLew DLuci BMan BWin MWya FDoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc.Additionally, DoorKing, Inc.This manual is copyrighted, all rights reserved. No portion of thisQuick Guide - 1. Quick Reference TablePrevious Page. Important Notices FCC - United States, DOC - CanadaTelephone Line WireGrounding and Surge Suppression. Wire ONE Unit to a Telco Line - Auto-Dialer. Wire ONE Unit to the Internet - Auto-DialerMain Terminal Description. Access Plus System Interface BoardRS-485 Daisy Chain Wiring.http://schlammatlas.de/en/node/16829 RS-485 Configurations, Sample of Multiple Unit Configuration Connection (Auto-Dialer ONLY). Network Connections. Phone Modem ConnectionSub-Net Mask (reboot required). Set the Gateway (Router) IP Address (reboot required). Set the Port Number (reboot required)Programming from the System Keypad. Programming from a Touch-Tone Telephone. Quick Reference TableDelete an Access Code (Simple and Time Zone Restricted). Delete All Access Codes for the Same Type of Device (Simple and Time Zone Restricted)Automatic Relay Activation Time Zone Programming (Up to 4). Access Code Time Zone Programming (Up to 4)Erase Transaction LogMicrophone Gain. Interface Board LED Status. System KeypadCall Waiting (1816 Access Plus Telephone Interface ONLY). Dial-Out Phone Numbers. Access CodesRemote Relay Activation (Touch-Tone Phone). Remote Relay Activation Check (Touch-Tone Phone)This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC. Rules and Regulations. These limits are designed to provide reasonable protection against harmful interference when theThis equipment generates, uses, and can radiate radio frequency energyOperation of this equipment in a residential area is likely to cause harmful interference in which case the user will beFCC Registration Number: DUF6VT-12874-OT-T. DOC - Canada. The Canadian Department of Communications label identifies certified equipment. This certification means that the equipmentThe Department does not guarantee the equipment will operate to the users satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable means of connection. The customer should beRepairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier.http://americanpatriotbeer.com/images/buick-enclave-user-manual.pdf AnyUsers should ensure, for their own protection, that the electrical ground connections of the power utility, telephone lines, andThis precaution may be particularly important in ruralCAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. DOC Registration Number: 1736 4507 A. Notice. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephoneThe termination on a loop may consist of any combination of devicesNotice. DoorKing does not provide a power transformer on units sold into Canada. Use only transformers that are CSA listed to powerThe Access Plus system requires a 16.5-volt, 20 VA transformer.This will help insure that you installation is performed in an efficient and professional manner. Check all localBe sure your installation is in compliance with local codes. The unit should beContinuous vibration and shock from slamming doorsUnder no circumstances should the unit be mounted directly to a moving door or gate.If this system is used to control entry through a vehicular gate or private entrance, theWhere a clear floor orMinimumMaximum 48”. HeightIf the high forwardHeight. MaximumWhere a clear floor or groundMinimumHeight 15”. MaximumClear Floor SpaceIf the side reach is overIf the side reach. MaximumHeightClear Floor Space. MaximumGreater than 10”Goose neck mounting post and kiosks work well for these type systems. When planning where to locate the system, take into consideration traffic lane layouts, turn around lanes for rejected access, conduit runs, powerSurface mount units are designed for direct outdoor installations, however it is preferable toFlush mount units must be protected from direct exposure to theInstruct the end user to never let children play with or operate any access controlBe sure that all dirt, metal or wood debris is removed from inside after mounting it.http://www.hediyevideo.com/wp-content/plugins/formcraft/file-upload/server/content/files/162934480690b4---a-modern-introduction-to-probability-and-statistics-solutions-manual.pdf Any debris inside could damage theWhen the Access Plus system is used to control a vehicular gate with an automatic gate operator, it must beIf desired, for added security against unauthorized entry into the system,Note: DoorKing cannot replace this specific lock or keys if lost.GroWi ndPluypadAc or. PlucessoSu unt. Mo. Remove the Control. Board and FaceplateThe control board removal is the sameCAUTION The control board containsFac. Hineplat. Lo ge eMfgFacAc O RThCoNoDaU. un. S. der. Pa onPaNoPaModewoo GSe 1. F.C plieRin VT istr. PaJa ger Eq 2874ion 68USO uiv. -OTC 0.0A TCarefully remove control board. Keep the control board in a protectedSee next page. Be sure the unit isAdPla terBack ViewD a t UC NGPr t o d eBu ine is de NT on Bu umEn ga an reToFront ViewDirectory.If Line is Busy, Press Any. Button to Hang Up. Try Again.Bottom ViewThe illustrations below show typical installations but specific installations can vary from this.Make any necessary conduit connections through the back or bottom of the enclosureDO NOT make any new conduit holes in the enclosure.DO NOT apply any power at this time. Mount to a Mounting Post. There are different stylesAdPla terSuM ace. En ountKnMoNote: A gooseneckDat. Sol 8No.AccDatWaSuM ace. En ountUse appropriateComplies F.C.C. Part 68Run all wiresUse hardware supplied withMount ON a Surface. KnConduitExamples of conduit runs that may be used, depending on howSome installations will allow theCreating Printed Directories for 1808 unit. The Access Plus Account Manager softwarePlus. The directory can then be easilyBe ms J CODFront ViewUse existing 4 holes in cabinetBottom ViewEnMount Directly toUse the 4 existing holes in the cabinet box. Run conduit inside or outside of wall orPlastic screwConduit shown inside wallInstallationMake sure that allDO NOT apply any power at this time.Surface mount units can be mounted directly to a wall, pilaster, post mounted using a DoorKing architectural style mounting.dakotaterritorycustomhomes.com/ckfinder/userfiles/files/breckwell-p26-cadet-manual.pdf Be sure the unit isCreating Printed Directories for 1810 unit. The Access Plus Account Manager softwarePlus. The directory can then be easilyCoBro SBro JBry KBy WBy RGaJon ADoPeRaReSeTylWyBottom ViewAdams JDubreuil M. Dukes DBack ViewBillings LBroker TBrose SFront ViewThe illustrations below show typical surface mount installations but specific installations can vary from this.Be sure that mounting screws (Not supplied) do notMake any necessary conduitDO NOT make any new conduitDO NOT apply any power at this time. Mount to an. Architectural. Mounting. Post. MoSuEn e MoKnMount ON a SurfaceWaMoUse hardware supplied withSu. Use appropriateEn e MoKnNote: An architecturalConduit runRun all wiresExamples of conduit runs that may be used, depending on how you choose to runMount In a SurfaceNOT have. The recess box gets installed inWARNING! If this entryLoWaPlaMoSpSuEncce MReBo ssKnRecess Box. Side View. Front ViewHolesAkins JAnde JApple HAustiBalsb DBassBern JBillin EBrok LBros TBrow SBrow JBrya KByro WByan RCard MCarn PCollin PColye GDoniDonn PDont KDown TDubrDuke MEngh DEllisFarro FFerna MGarfiGarre SGent JGonz MHabe HHamHend VHird KHoov AJens HJohn DJohn MJone TJone AMast DMozi FMuce JMulin J. Nabo B. MastNabu KNeum JNixon J. Patte RPerezRay AReige DRem BRessRollinSchu ASeele SSelle JShae HShan RSimo DSmit LSom JSynfo HTomlTompTomp ATylerWyat FFlush mount kits are NOT. INCLUDED with the flush mount entry system (See next page for flush mount kit installation).Flush mount surface mounting kits are NOT INCLUDED with the flush mount entry system (See page 14It is preferred that theyWe suggest that when they are mounted outdoors, it is in a covered protected area. Be sure the unit is mounted securely and isThe flush mount unit DOES NOT have aOpPreste Co eraHa deIn. Ennt ng-U Nu ber On stOn Try ber.AdN” n. ne Is yAk. Disp. BuAn. PresToAn e JAuThe Access Plus Account Manager softwarePlus.https://ohligschlaeger-berger.de/wp-content/plugins/formcraft/file-upload/server/content/files/1629344995b0ab---a-mother-s-manual-for-summer-survival.pdf The directory can then be easilyBa DBaBe JBilllin EBroBro TBro SBro JBry KBy WBy RDoDuDuEn DElliJon APeRaReRoSeTylWyBack View. Front ViewDownward LDubreuil MEnghard LAnnese JApplegate BGarfield SHitch FDill PDillon MBrown JThe flush mount kit has twoSlide the trim ring into theLoPlaMount In a SurfaceSpFluEnch MoWaMoTri. RinmKnBo -InWARNING! If this entryTo Ha ng If Di re CTUP Lin ctoAg Bu sySide ViewFront View. Front View. Threaded StudSide View. Hole for Threaded StudHolesBottom ViewHole. Bottom ViewFlush mount unit can be mounted ON aThe flush mountMoWa. FluEnch MoTrim Ring. KnThe flush mount unit DOES NOT have aExamples of someTo Ha ng If Di re CTUP Lin ctoAg Bu syTrim Ring. Side ViewBottom ViewThe flush mount kit (Sold separately, see previous page) is installed intoSecure the rough-in box in the kiosk. Run all necessary wires toLo. PlaSp. Tri. RinmFluEnch MoKnRoBo -InAt some locations, such as gated communities, it will be necessary to provide access to the mail carrier so that they canThis is the same lock that the. Post Office uses for gang mailboxes. These locks are not available to the public.If you are using the 1808 and need postal service. Prior to installation of the postal lock, be sure power to the access plus system is turned OFF.Mount postal lock on the studs and secure with the hex nuts. When the lock is installed, the pawl of the lock, in the extended position is depressing the switch. When the mail carrier insertsBernas J CODE. Bro rd EDi tePrIf Lins Coy. Nu m. Bu e is de Nu be rTry n Bu mEn ain ng esUp s AnToDonic PDonn PDonte KHird KHoov AJense HJohns DJohns MJones T. Jones ALucid BManc BMasti GMasto D. Mozinn FMuce JMulin J. Nabo BNabu KNeum JNixon J. PatterRPerezRay ASchus A. Seele terSellec JShaer H. ShankRSmith L. Soma JSteele H. Stolla FSynfo HTomliTompTomp AWyatt FDomi DDonic PDonn PDonte KHend er VHird KHoov AJense HJohns DJohns MJones T. Jones ALewis D. Lucid BManc BMasti GMasto D. Patte RPerezRay ARollinSchu ASeele SSellec JShaer H.https://www.americanapi.com/wp-content/plugins/formcraft/file-upload/server/content/files/16293449c959d6---A-modern-introduction-to-probability-and-statistics-solutions-manual-pdf.pdf Shan RSimo DSmith L. Stolla FSynfo HTomliTompWyat FHo faceHo sh MHo al BoRelay Activates. CommonWithdrawn PawlExi -mouPo sep. Exi locWiW m. CoFac itch osta tely.S ide P eparaBe sure to observe electrical safety when working with phone lines. Phone lines carry electricity and the ring voltage can deliverIn most residences, the phone cable contains four wires; green, red, black, yellow. The green and red are twisted to make oneMost phone lines installed in the U.S. in the second half of the 20th Century have this type ofAll new telephone projects are using Cat5 wire. If you have Cat5 wiring in yourGreen. Four Conductor. Wire. Red. ConversionYellow. Ring (-). Black. Older ResidencesBlue Pair. Cat5 WireOrange Pair. The convention for Cat5 wire is as follows. Green PairBrown PairGREEN grass third; BROWN earth last. Modern ResidencesCommon terms in the telephone service industry referring to the two wires or sides ofTip is the ground side (positive) and Ring is the battery (negative) side of a phone circuit. ThePhone Line Polarity. Tip and ring reversal is mostly immaterial, except for special circuits including DID (Direct Inward. Dialing) trunks, T-1 lines, and ground start lines where the field side (“terminal”) equipment (a company's PBX switch, forWire Type. It is extremely important to use the correct type of wire in telephone applications. Since the Access Plus systemFor example, use Cat5e Gel Filled (flooded) UV Resistant Direct Burial Cable run inDo not use thinly insulated brown-jacketed telephone wire (theUsing improper wire can cause noise andBe sure that phone wire pairs are twisted. Wire Size and Distance. Phone lines can be run up to 3600 feet, provided that the proper wire size is used. Telephone Wire Run TableMax DistanceUnderground Cutaway. Telephone. Wire Conduit. Electrical field from power wires.High Voltage. Power Wire. Conduit. Note: Do not run telephone wires and high voltage powerSeparate the high voltageThe Access Plus system operates ONLY on 16.www.fuelignitethrive.com/files/breckwell-p24i-manual.pdf5 VAC. DO NOT power the unit with 24 volt AC power. Use the supplied powerDO NOT power any other devicesSee table below for wire run distances. Power Transformer Wire Run Table. Wire Size. Max DistancePower Interruption Note: The Time. Supplied Transformer and Date calendar chip (Section 2,Ou CPolarity does DoorKing offers a 12 volt.8 ampPower Transformer WiresDamage will occur to the unit that is. NOT covered under DoorKing’s warranty.Proper Grounding and the use of surge suppressors can significantly reduce the chance of component failure because of staticThe ground point can be at an electrical panel, a metallic cold water pipe that runs in theA gooseneck mounting post anchored in concrete does NOT makeSome Acceptable Ground Sources. IMPORTANT: Ground wire shown withoutElectrical. Panel. Ground. Ground to existing electrical system. Ground to metallic cold water pipe. Grounding rod 10 feet in soil. Telephone Line Surge Suppressor. It is highly recommended that telephone line surgePhone CompanySurge suppressorIt is highly recommended that a low voltage surgeSurge suppressor withinConnect to Incoming Telephone Company’s. Phone LineSystem. Phone at. Central Office (C.O.). Demarcation Device. Telco. Tip. RingCat5e. Ring. Cat5e Without. Surge Board. Access Control Devices. Check Polarity of Telephone Line. Be sure to properlySee section 1.5 forCheck for polarity on the phone “IN” wires, terminals 1 andPlace the positive lead onIf the meter shows a negativeGroundVehicular. Gate OperatorDoReadInc. InglewoMain. TerminalUse minimum 18. AWG wire for runsFor best protection, surge suppressor groundTelephone LineRecommended. Locate unit’s Phone Line. Inside Device. Company. Demarcation. PointMin. Within 3 ftLocate the telephone company demarcation device. IMPORTANT Identify the telephone line that will connect to the Access PlusUse only twisted pair telephone wire that is rated for direct undergroundRecommend Cat5e Gel Filled (flooded) UV Resistant Direct Burial Cable inOptional Phone Line Surge SuppressorSeparate UL. Listed Power. Transformer. Electric. StrikePolarity does not matter.Ou VACMagnetic locks or electric strikes must beThe Access Plus system operates ONLYDO NOT powerSee section 1.4 for wire size and runRecommended. RecommendedOptional Low Voltage Surge SuppressorWithin 3 ftFor best protection, surge suppressor ground wire. MUST be 3-ft. or less in length. Use minimum 12 AWGTypical “Existing”. Internet Source. Internet. Modem. Router. VolP. DevConnector. Telephone Line (Cat5e). Cat5e. For complete information,Check Polarity of Telephone Line. Jack. Access Control DevicesVehicular. Gate Operator. Use minimum 18. AWG wire for runsDoReadInc. InglewoSeparate UL. StrikeCheck for polarity on the phone “IN” wires, terminals 1 andPlace the positive lead onIf the meter shows a negativeBe sure to properly ground. ALL boards. See sectionGroundMain. TerminalPolarity does not matter.Ou VACMagnetic locks or electric strikes must beDO NOT powerGroundSee section 1.4 for wire size and run Within 3 ftRecommended. RecommendedFor best protection, surge suppressor ground wire. MUST be 3-ft. or less in length. Use minimum 12 AWGWiring. Configuration. Ground 12 AWG. Min. Within 3 ftVolP. Dev. Phone Line Phone InPhone InSee previous 2Internet wiring.Be sure to properly ground ALLPhone InPhone InPhone InCheck for polarity on the phone “IN” wires, terminals 1 and 2. Terminal 2 must be positive with respect to terminal 1. Set a VOMPlace the positive lead on terminal 2TerminalFor best protection, surge suppressor ground wire MUST beCheck Polarity of Telephone Line. Telco Phone. Line. Optional Phone Line Surge Suppressor. Relay 2 to Access Control Device. To 16.5 VAC Supplied TransformerRelay 2. PowerWhen connectingAccess Plus units, theThe master codeNOT function togetherGround 12 AWG Min. To next Access Plus System. Connect up to 5 units on ONE phone line. Maintain polarity when connectingRelay 1 to Access Control Device. See previousRelay 2 to Access Control Device. To 16.5 VAC Supplied TransformerTerminalRelay 2. PowerTelco Phone Line - OPTIONAL. The RJ71 wiring configuration is not recognized byFor Bell Canada (Ontario. Quebec), refer to CA-79X block for interconnectionRelay 00 is reserved for Central Office (C.O.)Auto-dialer and modem programming. RelayRelayOptional Incoming Central Office (C.O.)Optional Incoming Central Office (C.O.)One (1) connecting cable is required forBoard and one (1) 1982-010 Relay. Board. Second Relay Board is orderedSet to left (Phone Line) if resident hasSet to rightOutside phone lines can be added if desiredDirectory codes 01 to 23 are for use with theProgram these directory codes if using thisOutgoing phones lines to individual apartments. Optional Central Office phone line isSecond. Relay. Board. RinmFluEnch MoKnRoBo -InAt some locations, such as gated communities, it will be necessary to provide access to the mail carrier so that they canThis is the same lock that the. Post Office uses for gang mailboxes. These locks are not available to the public.If you are using the 1808 and need postal service. Prior to installation of the postal lock, be sure power to the access plus system is turned OFF.Mount postal lock on the studs and secure with the hex nuts. When the lock is installed, the pawl of the lock, in the extended position is depressing the switch. When the mail carrier insertsBernas J CODE. Bro rd EDi tePrIf Lins Coy. Nu m. Bu e is de Nu be rTry n Bu mEn ain ng esUp s AnToDonic PDonn PDonte KHird KHoov AJense HJohns DJohns MJones T. Jones ALucid BManc BMasti GMasto D. Mozinn FMuce JMulin J. Nabo BNabu KNeum JNixon J. PatterRPerezRay ASchus A. Seele terSellec JShaer H. ShankRSmith L. Soma JSteele H. Stolla FSynfo HTomliTompTomp AWyatt FDomi DDonic PDonn PDonte KHend er VHird KHoov AJense HJohns DJohns MJones T. Jones ALewis D. Lucid BManc BMasti GMasto D. Patte RPerezRay ARollinSchu ASeele SSellec JShaer H. Shan RSimo DSmith L. Stolla FSynfo HTomliTompWyat FHo faceHo sh MHo al BoRelay Activates. CommonWithdrawn PawlExi -mouPo sep. Exi locWiW m. CoFac itch osta tely.S ide P eparaBe sure to observe electrical safety when working with phone lines. Phone lines carry electricity and the ring voltage can deliverIn most residences, the phone cable contains four wires; green, red, black, yellow. The green and red are twisted to make oneMost phone lines installed in the U.S. in the second half of the 20th Century have this type ofAll new telephone projects are using Cat5 wire. If you have Cat5 wiring in yourGreen. Four Conductor. Wire. Red. ConversionYellow. Ring (-). Black. Older ResidencesBlue Pair. Cat5 WireOrange Pair. The convention for Cat5 wire is as follows. Green PairBrown PairGREEN grass third; BROWN earth last. Modern ResidencesCommon terms in the telephone service industry referring to the two wires or sides ofTip is the ground side (positive) and Ring is the battery (negative) side of a phone circuit. ThePhone Line Polarity. Tip and ring reversal is mostly immaterial, except for special circuits including DID (Direct Inward. Dialing) trunks, T-1 lines, and ground start lines where the field side (“terminal”) equipment (a company's PBX switch, forWire Type. It is extremely important to use the correct type of wire in telephone applications. Since the Access Plus systemFor example, use Cat5e Gel Filled (flooded) UV Resistant Direct Burial Cable run inDo not use thinly insulated brown-jacketed telephone wire (theUsing improper wire can cause noise andBe sure that phone wire pairs are twisted. Wire Size and Distance. Phone lines can be run up to 3600 feet, provided that the proper wire size is used. Telephone Wire Run TableMax DistanceUnderground Cutaway. Telephone. Wire Conduit. Electrical field from power wires.High Voltage. Power Wire. Conduit. Note: Do not run telephone wires and high voltage powerSeparate the high voltageThe Access Plus system operates ONLY on 16.5 VAC. DO NOT power the unit with 24 volt AC power. Use the supplied powerDO NOT power any other devicesSee table below for wire run distances. Power Transformer Wire Run Table. Wire Size. Max DistancePower Interruption Note: The Time. Supplied Transformer and Date calendar chip (Section 2,Ou CPolarity does DoorKing offers a 12 volt.8 ampPower Transformer WiresDamage will occur to the unit that is. NOT covered under DoorKing’s warranty.Proper Grounding and the use of surge suppressors can significantly reduce the chance of component failure because of staticThe ground point can be at an electrical panel, a metallic cold water pipe that runs in theA gooseneck mounting post anchored in concrete does NOT makeSome Acceptable Ground Sources. IMPORTANT: Ground wire shown withoutElectrical. Panel. Ground. Ground to existing electrical system. Ground to metallic cold water pipe. Grounding rod 10 feet in soil. Telephone Line Surge Suppressor. It is highly recommended that telephone line surgePhone CompanySurge suppressorIt is highly recommended that a low voltage surgeSurge suppressor withinConnect to Incoming Telephone Company’s. Phone LineSystem. Phone at. Central Office (C.O.). Demarcation Device. Telco. Tip. RingCat5e. Ring. Cat5e Without.