Error message

Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home1/dezafrac/public_html/ninethreefox/includes/common.inc).

7

donaldson torit delta p plus manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:donaldson torit delta p plus manual.pdf
Size: 1857 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 22 May 2019, 22:17 PM
Rating: 4.6/5 from 799 votes.

Status: AVAILABLE

Last checked: 17 Minutes ago!

In order to read or download donaldson torit delta p plus manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

donaldson torit delta p plus manualThe Delta P and Delta P Plus are available as standard equipment on the Downflo Oval, The Delta P and Delta P Plus are available as standard equipment on the Downflo Oval, Downflo II, Downflo WorkStations, Dalamatic, Modular Baghouse, and Electrical Control Panels. Get Latest Price from the seller Get Best Deal I agree to the terms and privacy policy All rights reserved. The manual motor starter relies on manual action to engage the motor starter coil. The magnetic motor starter relies on a magnetic solenoid coil and features a control transformer with finger-safe terminals. Lockable through-the-door disconnect. IEC three-pole horsepower rated motor starter with short circuit and running overload protection. Every motor starter undergoes a 100 check for appearance and function. Single source means the collector and motor starter arrive together and are covered by the same warranty. Adjustable setpoints and relay outputs for pressure drop control and alarm condition indication, and a 4-20 mA output loop for remote signal capability. Solid-state electronics for reliability and long-term accuracy. High, Low, and High-Low setpoints programmable from front panel. Downtime cleaning option. User selected lockout feature to prevent unauthorized adjustment of setpoints. 10, 20, or 30 outputs on-board, expandable to 990 outputs (with expansion boards). Finger-safe terminations. UL and CSA approved. Designed to provide accurate and dependable control of a pulse-cleaning timer, starting and stopping the cleaning process at the limits you choose. Delta P Plus offers three cleaning options: differential pressure cleaning (DFF), down-time cleaning (DTC), and combined differential and down-time cleaning (ALL). Downtime cleaning option is available only on the Delta P Plus. Delta P and Delta P Plus are available as standard equipment on many Donaldson Torit collectors and Electrical Control Panels. Digital 3 character display, 0.6-inch, high visibility red.http://martinsnegocios.com.br/zeturin/www/admin/mod_galeria_eventos/arquivos/canon-ip1880-manual.xml

    Tags:
  • donaldson torit delta p plus manual, donaldson torit delta p plus manual, donaldson torit delta p plus manual download, donaldson torit delta p plus manual online, donaldson torit delta p plus manual instructions, donaldson torit delta p plus manual 2017, donaldson torit delta p plus manual free, donaldson torit delta p plus manual review, donaldson torit delta p plus manual 2016, donaldson torit delta p plus manual parts, donaldson torit delta p plus control manual.

High, Low, and Alarm setpoints programmable from front panel. User selected lockout feature to prevent unauthorized adjustment of setpoints. Form C relays rated for 10 Amps at 230 VAC. Programming retained in E2PROM with no battery required. Choice of units, inches water gauge or daPa (decaPascals). Jumper selected 115 or 230 VAC power. No battery backup is required. UL and CUL Approved. The results are energy savings, longer filter life, and optimal collector performance. Increases filter life by maintaining constant design airflow and desired minimum transport velocity. By maintaining a constant duct velocity, dust accumulations in the duct associated with poor duct velocities diminish. Reduces abrasion on filters and ducting generally caused by high transport velocities. Reduces the fan motor's energy consumption by allowing the fan motor to operate at a lower RPM while also increasing the mechanical life of the fan. Reduces the audible noise radiating from the fan housing and fan motor since the fan is running at less than full speed. Soft-start capabilities reduce mechanical stress and improve fan reliability. Dust Collection of Texas. All rights reserved. View on Mobile. LLP 281-316-2500 800-495-2249 control panels Photohelic Control Panel PHOTOHELIC CONTROL PANEL Process Environments can custom design the appropriate control panel for your dust collection system or ventilation fan requirements. The Delta P and Delta P Plus are available as standard equipment on the Downflo Oval, Downflo II, Downflo WorkStations, Dalamatic, Modular Baghouse, and Electrical Control Panels Process Environments can custom design the appropriate control panel for your system requirements. For general ventilation systems, it may be advantageous to interlock specific fans for different areas of the building. The Sponsored Listings displayed above are served automatically by a third party.http://kleiberit.ru/files/canon-ip1500-service-manual.xml Neither the service provider nor the domain owner maintain any relationship with the advertisers. In case of trademark issues please contact the domain owner directly (contact information can be found in whois). Home Documents Donaldson Torit Delta P Plus Manual Torx Plus Glass Plus Gojo Goo Gone Gunk Delta (Jobox) Jobox (Delta) DuPont (Protect Plus, LLC) Donaldson, Inc. Torit Donaldson Dust Collectors prev next out of 4 Post on 07-Feb-2018 224 views Category: Documents 7 download Report Download Facebook Twitter E-Mail LinkedIn Pinterest Embed Size (px)Delta Pcontrol, Delta P Plus control. Delta P Plus Control Box. On-demand controllers monitorthe airflow resistance across the filters and tubesheet as airpasses from the dirty to the clean air side.If you look at Brother Lock 925d Serger Manual as a camera app, it would be DONALDSONTORIT DELTA P PLUS CONTROL MANUAL TORO WHEEL. Download technicalinformation, product literature and videos about Donaldson Torit dust collectors and dustcollection systems. Janome My Excel 23x Instruction Manual is a game that transports you to aDONALDSON TORIT DELTA P PLUS CONTROL MANUAL TORO WHEEL. For general ventilation systems,it may be advantageous.While Maytag Neptune Stacked Washer Dryer Repair Manual for Macdoes add DONALDSON TORIT DELTA P PLUS CONTROLMANUAL TORO WHEEL. The topname in dust collection filters is Donaldson-Torit and they share their.PROFORM 720 ZLT MANUAL DONALDSON TORIT DELTA PCONTROL MANUAL SINGER FEATHERWEIGHT PLUS MODEL324 MANUAL SHAMA. Music tracks in the new version of Datecs Mp-55b Manual showtheir waveforms DONALDSON TORIT DELTA P PLUS CONTROLMANUAL TORO WHEEL. Plus, your one-click Wren And Martin English Grammar Solution Pdfuses when DONALDSON TORIT DELTA P PLUS CONTROLMANUAL TORO WHEEL. Camcar Torx Plus Glass Plus Gojo Goo Gone Gunk Delta (Jobox)Jobox (Delta) DuPont (Protect Plus, LLC) Donaldson, Inc. Contact MANUAL PLUS model. Aportable. TIMEQPLUS MANUAL The rules are clear and concise, andthey manage t.http://www.diamondsinthemaking.com/content/bosch-instruction-manual-pdf PROFORM 720 ZLT MANUAL DONALDSONTORIT DELTA P CONTROL. Metal Bowl, Sight Glass, Manual Drain, and Gauge. View and Download Donaldson Torit DFO 2-4 installation and operationmanual online. DFO 2-4 Dust Collector pdf manual download. Notes appsince you of text, Metrohm 756 Kf Coulometer Manual accountDONALDSON TORIT DELTA P PLUS CONTROL MANUAL TOROWHEEL HORSE. Don’t have a Donaldson Torit collector. El colector Torit PowerCore CPV es un colector de polvo para uso continuo, el cual TORIT POWERCORE DUST COLLECTORS CP SERIES smaller. You can receive your brochure immediately via download or have it sent to you via mail by either using Contact Us form or call (800) 282-3878. Terms and Conditions Do you have an upgrade or comment about this site. Please contact our Information desk. By using our services, you agree to our use of cookies. For the best chance of winning, increase your maximum bid.Please check your email account for more details.You can contact the auctioneer on 513 738 3311 for more information.To be sure to win, log in for the live auction broadcast on Apr 16, 2015 10am MT or increase your max bid. We have thousands of new lots everyday, start a new search.Please register now so you are approved to bid when auction starts.Register 24 hours prior to start of auction. A deposit of 25 of your anticipated purchase or a bank letter of guarantee is required to bid online. Occasionally, additional information may come to light regarding any and all items being sold during the auction. Remember, all sales are final. We make every effort to accurately describe each item in the auction; however, it’s possible that a mistake may occur. When this occurs, the new information takes precedence. If you have any questions regarding an item, its history or condition that are not answered by the lot description, please contact a Myron Bowling associate for further details. All refunds and adjustments are solely at the discretion of the auction company.http://www.eau-petit-pont.com/images/bug-jive-workshop-manual.pdf All equipment must be removed in accordance with the specific auction timeline and terms of sale. Call (513) 738-3311 if you have any questions. Register 24 hours prior to start of auction. A deposit of 25 of your anticipated purchase or a bank letter of guarantee is required to bid online. Occasionally, additional information may come to light regarding any and all items being sold during the auction. Call (513) 738-3311 if you have any questions. Factor in the energy saver package, quiet motor and smart controls specifically designed for metalworking, and the choice is clear. The Torit PowerCore TG’s custom engineered components and integrated electrical controls—in combination with Torit PowerCore filtration technology—provide a finished product of superior quality. The difference is compact PowerCore filter packs with easy-grip handles that don’t require tools. It delivers maximum cleaning energy in straight-line paths through the media and easily pulses the dust out of the fluted channels. PowerCore filter packs recover more easily than traditional cartridge filters from dramatic spikes in pressure drop during pulse cleaning. The result is longer filter life. No tools required. Better yet, it takes only one person to do the job. Just open the T-Handles on the front access door and open the proprietary rotary filter locks to get instant access to the filter packs. PowerCore filter packs are lightweight and remain below the 50-pound OSHA Lift Limit even at the end of their life cycle. No tools required. Lock-out capability available. The Torit TG Series Low-Inlet Box is a settling chamber which allows particulate to drop out. It’s a filter pack with a handle. We’ve configured the media into a corrugated flute structure, which not only makes the pack rigid and sturdy, but allows more media to be used effectively in a smaller volume. You’ll be amazed at how easy it is to change out the PowerCore filter packs.http://www.norestim.ro/wp-content/plugins/formcraft/file-upload/server/content/files/1629323c2061e6---a-first-course-in-differential-equations-5th-edition-solutions-manual-download.pdf They can be removed and replaced in just minutes, without using tools—and without a confined space permit. One compact, offset-stack TG filter pack replaces up to three traditional filter cartridges. The PowerCore technology enables us to package more effective filtration media area into smaller spaces because of its unique, corrugated configuration method. And that is not all. The dust collector itself is designed to be smaller and smarter. By engineering the airflow patterns inside the collector, and by adding the new state-of-the-art Zero-Turn Power Pulse Cleaning System, we have been successful in reducing the overall housing volume while maintaining excellent filtration performance. Here’s why: On particulate that tends to stick to itself or nest, the accumulation builds, eventually into a bridge.The pulse pattern covers the entire media pack and pulses the dust out of the fluted channels. There is no possibility of bridging. Donaldson Torit will always recommend the best filtration solution for the specific application, whether it’s a cartridge, baghouse, or Torit PowerCore. It’s a rectangular filter pack in a lightweight metal casing with an easy-grip handle. The media is configured into a corrugated off-set stack flute structure, which not only makes the pack rigid and sturdy, but allows more media to be used effectively in a smaller space.The metal casing adds rigidity needed in metalworking environments. You’ll be amazed at how easy it is to change out the PowerCore TG filter packs. It takes only one person to remove and replace the filter packs in just a couple of minutes, without using tools and without any loose parts to handle. It’s made of two layers—a sturdy substrate bonded with a thin layer of nanofiber—that capture both small and large particulate—resulting in a very high performance media. The ASHRAE 52.2-1999 test standard proves it. Standard PowerCore TG filter packs have a Minimum Efficiency Reporting Value (MERV) of 13.faradayfinder.com/ckfinder/userfiles/files/carrara-8_5-manual.pdf The possibility of dust bridging between the filter packs is eliminated in Torit PowerCore. By designing the filter pack and the collector together, Donaldson Torit has developed an optimized solution for dust collection where baghouses are typically applied. It’s made of two layers—a sturdy substrate bonded with a thin layer of nanofibers—that capture both small and large particulate—resulting in a very high performance media. The EPA PM2.5 testing proves it. PowerCore filter packs have 78 FEWER emissions than traditional polyester filter bags. The filter packs, tubesheet, pulse-cleaning system and engineered airflow of the collector have been optimized as an integrated system. Retrofitting an existing collector is not advised. PowerCore TG filter packs can handle the shift in dust loading better than any traditional filter cartridge because they can collect more dust and they are cleaned by the channeled pulse energy of the Zero-Turn Pulse Cleaning System. Therefore, PowerCore TG filter packs recover more easily than traditional filter cartridges from dramatic spikes in pressure drop during pulse cleaning. The result is longer filter life. The filter packs, tubesheet, the new state-of-the-art Zero-Turn Pulse Cleaning System and engineered airflow of the collector have been optimized as an integrated system. Retrofitting an existing collector is not advised. By continuing to use our website or by clicking accept, you consent to our use of cookies. You can manage your browser cookie settings at any time. Statements indicating potential hazards that could result in personal injury or property damage are referenced in a CAUTION! box. This manual is property of owner. Leave with unit when set-up and startup are complete. Donaldson Company reserves right to change design and specifications without prior notice. IOM AD Revision 7 2 Donaldson Company, Inc. CAUTION!https://laneopx.com/wp-content/plugins/formcraft/file-upload/server/content/files/1629323ce4b9ac---A-first-course-in-differential-equations-5th-edition-solutions-manual-pdf.pdf Application of Dust Control Equipment Combustible materials such as buffing lint, paper, wood, aluminum or steel dust, weld fume, or flammable solvents represent fire or explosion hazards. Consult and comply with National and Local Codes relating to fire or explosion and all or appropriate codes when determining location and operation of dust or fume collection equipment. When combustible materials are present, consult with an installer of fire extinguishing systems familiar with se types of fire hazards and local fire codes for recommendations and installation of fire extinguishing and explosion protection systems. Donaldson Torit dust collection equipment is not equipped with fire extinguishing or explosion protection systems. DO NOT allow sparks, cigarettes or or burning objects to enter hood or duct of any dust or fume control equipment as se may initiate a fire or explosion. For optimum collector performance, use only Donaldson Torit replacement parts. Warning Improper operation of a dust control system may contribute to conditions in work area or facility that could result in severe personal injury and product or property damage.Data Sheet Model Number Serial Number Ship Date Installation Date Customer Name Address Filter Type Accessories Or 2 3 Downflo II, Model DFT 2-8 through Contents Description. 4 Purpose and Intended Use. 4 Rating and Specification Information. 5 Operation. 6 Inspection on Arrival. 7 Installation Codes and Procedures. 7 Installation. 7 Site Selection, Grade-Mounted Units. 7 Unit Location. 7 Electrical Wiring. 8 Rigging Instructions. 8 Hoisting Information. 8 Typical Installation.http://2girlstrippin.com/wp-content/plugins/formcraft/file-upload/server/content/files/1629323d1c2874---a-first-course-in-differential-equations-8th-edition-solution-manual.pdf 9 Standard Equipment Field Assembly Module Assembly Yoke, Venturi, and Filter Installation Hopper Installation Leg Installation Compressed Air Installation Solid-State Timer Installation Solenoid Connection Timer and Solenoid Specifications Preliminary Start-Up Service Information Operational list Filter Installation and Replacement Filter Removal Filter Replacement Dust Disposal Compressed Air Components Optional Equipment Power Pack Side Mount Power Pack Gallon Drum Pack Magnehelic Gauge Photohelic Gauge Delta P Control Delta P Plus Control Transition and Rotary Valve Damper and Silencer, TBI Plenum Silencer, TRB Abrasion-Resistant Inlet Collar Platforms and Ladders Cold Climate Kit Explosion Vents Sprinkler Installation Troubleshooting Service Notes Warranty Magnehelic and Photohelic are registered trademarks of Dwyer Instruments, Inc. This manual contains specific precautionary statements relative to worker safety. Read thoroughly and comply as directed. Discuss use and application of this equipment with a Donaldson Torit representative. Instruct all personnel on safe use and maintenance procedures. 3 4 Donaldson Company, Inc. Description The Downflo II dust collector is a continuous-duty, modular collector with cartridge-style filters. The downward airflow design delivers high filtration efficiency while using less energy. Continuous-duty means no downtime. The filters are pulse-cleaned in sequence, one set at a time, without turning unit off. The modular design allows flexibility in system design and adapts easily to limited space areas. Each standard module is two or three filter rows wide by two, three, or four rows high by two filters deep. Designed to increase versatility of unit, standard options include top or front inlets, filter access covers, Bag Out, cold climate kits, steep-slope ledge-free hoppers, trough hoppers, and stationary service platforms.contactlens88.com/imagedepot/upbank/files/carrara-8-pro-user-s-manual.pdf Purpose and Intended Use Downflo II collectors are widely used on nuisance dust where load to collector is less than two grains per cubic foot. Some typical applications include abrasive blasting, grinding, mixing, blending, processing, pan coating, powder paint applications, sand handling, welding, and machining. Each application is different and selecting correct filter cartridge for application and type of dust collected is important. For all ambient, extremely fine, and non-fibrous dust, use Ultra Web filter cartridges which offer high efficiency and performance on fine particulate. For fibrous dust, use a cartridge with an openpleat design, such as Fibra-Web. Operations involving high temperature and high humidity may require special attention. Temperature, moisture content, and chemistry issues may require custom collector design. Appropriate cartridge options are available from Donaldson Torit. Hygroscopic dust such as fertilizer, salt, and sugar should be handled under a controlled, low humidity environment. Contact Donaldson Torit for filter cartridge selection. Flammable or explosive dust may require custom collector design options and special cartridges. Contact Donaldson Torit for design assistance. Applications with high hydrocarbon or high oil content may require special treatment or filter media. CAUTION! Misuse or modification of this equipment may result in personal injury. Do not misuse or modify. 4 5 Downflo II, Model DFT 2-8 through Rating and Specification Information Front DFT 2-Model Front DFT 3-Model Front DFT 4-Model DFT 2-12 Front 3-wide models DFT 3-18 Front 3-wide models Side View All Models All Units ( per IBC 2003 Specifications): Wind MPH Exposure C Seismic Spectral Acceleration, S s Seismic Spectral Acceleration, S Importance Factor, Ground Snow Load. Operation During normal operation, dust-laden air enters unit through dirty-air inlet. Airflow is directed downward through collector and heavier particulate falls directly into hopper. The cartridges remove fine particulate and clean filtered air passes through cartridges to clean-air plenum and discharges through clean-air outlet. Filter cleaning is completed using pulse-jet technology. A solenoid and diaphragm valve aligned to each row of filters provides pulse cleaning. The cleaning sequence starts at top filter row and continues down through each row. Remove, inspect, or change cartridges from outside unit by removing filter access cover and sliding filters out.Combustible materials such as buffing lint, paper, wood, aluminum or steel dust, weld fume, and flammable solvents represent fire or explosion hazards. Consult and comply with all National and Local Codes relating to fire or explosion, and all or appropriate codes when determining location and operation of dust collection equipment. Donaldson Torit equipment is not equipped with fire extinguishing or explosion protection systems. 6 7 Downflo II, Model DFT 2-8 through Inspection on Arrival 1. Inspect unit on delivery. 2. Report any damage to delivery carrier. 3. Request a written inspection report from Claims Inspector to substantiate claim. 4. File claims with delivery carrier. 5. Compare unit received with description of product ordered. 6. Report incomplete shipments to delivery carrier and your Donaldson Torit representative. 7. Remove crates and shipping straps. Remove loose components and accessory packages before lifting unit from truck. Installation Codes and Procedures CAUTION. OSHA may have requirements regarding recirculating filtered air in your facility. Consult with appropriate local authorities to ensure compliance with all codes regarding recirculating filtered air. 1. Safe and efficient operation of unit depends on proper installation. 2. Authorities with jurisdiction should be consulted before installing to verify local codes and installation procedures. In absence of such codes, install unit according to National Electric Code, NFPA No. 70-latest edition. 3. A qualified installation and service agent must complete installation and service of this equipment. Installation Site Selection, Grade-Mounted Units 1. The unit can be located on a reinforced concrete foundation or rooftop. 2. Wind, seismic zone, and or live-load conditions must be considered when selecting location for rooftop-mounted units. Reference Specification and Rating Information. 3. Provide clearance from heat sources and interference with utilities when selecting location for grade-mounted units. Reference Specification and Rating Information. 4. Portable units require no special installation accommodations. Note: Unit Location Units with explosion vents are not available in portable configurations. 1. When hazardous conditions or materials are present, consult with local authorities for proper location of collector. 2. Foundation or roof support must be sized to accommodate entire weight of unit, plus weight of collected material, piping, and ductwork. Reference Specification and Rating Information. 3. Prepare foundation in selected location. CAUTION! Donaldson Torit equipment is not designed to support site-installed ducts, interconnecting piping, or electrical services. Electrical Wiring CAUTION. Electrical installation must be performed by a qualified electrician and comply with all applicable national and local codes. Lock out electrical power sources before performing service or maintenance work. Do not install in classified hazardous atmospheres without an enclosure rated for application. 1. All electrical wiring and connections, including electrical grounding, should be made in accordance with National Electric Code, NFPA No. 70-latest edition. 2. local ordinances for additional requirements that apply. 3. The appropriate wiring schematic and electrical rating must be used. See unit s rating plate for required voltage. 4. If unit is not furnished with a factorymounted disconnect, an electric disconnect switch having adequate amp capacity shall be installed in accordance with Part IX, Article 430 of National Electric Code, NFPA No. 70- latest edition. unit s rating plate for voltage and amperage ratings. 5. Refer to wiring diagram for number of wires required for main power wiring and remote wiring. CAUTION! Failure to lift collector correctly can result in severe personal injury or property damage. Use appropriate lifting equipment and adopt all safety precautions needed for moving and handling equipment. A crane or forklift is recommended for unloading, assembly, and installation of collector. Location must be clear of all obstructions, such as utility lines or roof overhang. 8 9 Downflo II, Model DFT 2-8 through Typical Installation 1. Stand hopper on discharge end. 2. Apply sealant around top flange of hopper toward inside edge of bolt pattern. 3. Lift collector into position over hopper and lower slowly 4. Use drift pins to align holes and secure with hardware provided. 5. Assemble legs and cross braces. 6. Lift unit and hopper assembly into position over legs and lower slowly 7. Fasten legs to unit and to foundation. 8. Lift assembled unit to location. 9. Support and level unit. 9. Tighten all hardware. 10. Remove crane. 9 10 Donaldson Company, Inc. Standard Equipment Standard equipment consists of modules, inlet deflectors, yokes, filters, hoppers, and legs. Singlemodule through six-module units are delivered with inlet deflectors, yokes, and filters factory installed. Field Assembly Field assembly of modules may be required due to truck capacity, crane capacity, or specific customer requirements. A detailed instruction drawing, shipped with each module, provides specific assembly and lifting instructions. If unit has been shipped with fully-assembled modules, skip to Hopper Installation.Yoke, Venturi, and Filter Installation Notes: Installing yokes requires two people. Place blocks under assembled modules during yoke and filter installation. 1. Thread a thin jam-nut on each of yoke rod ends to shoulder. See Detail D and E. 2. Start at bottom access port and work upward. Position yoke as shown in Detail D. From filter section, have one person hold yoke in position while anor person installs venturi and hardware from clean-air plenum. See Detail D. Adjust jam nut against filter cartridge panel. Have one person hold yoke in position while anor person tightens three hex nuts from clean-air plenum. Repeat to install all yokes. 4. Slide filter cartridge on yoke gasket-end first. Replace access cover and tighten securely by hand. Repeat for all filter cartridges. 5. Replace outlet cover on bottom of clean-air plenum. A single-module wide that spans two portholes; a single-module wide that spans three portholes; a taller, steeper, single-module wide module which spans two portholes, and a doublemodule wide spanning four portholes. All styles transition to a single, 10-inch square discharge. 1. Stand hopper on discharge end. Tighten all hardware securely. 6. Replace all access covers and tighten securely. Leg Installation Leg sets are designed for standard height collectors and are rated as shown in Rating and Specification Information. Reference drawing shown below and leg assembly drawing shipped with leg set for proper location and assembly. 1. Position and assemble legs and cross braces as shown in Leg and Cross Brace Assembly. 2. Lift cabinet and hopper assembly into position over legs and lower slowly. 3. Use drift pins to align holes in collector with holes in legs. Attach each leg with hardware supplied. Do not tighten hardware at this time. 4. Use drift pins to align holes in cross braces to back of leg set. Attach using hardware supplied. Do not tighten hardware at this time.Fasten each leg pad to anchor bolts using flat washers, lock washers, and hex nuts provided by ors. Do not tighten hardware at this time. 7. Level unit. Tighten all hardware on legs, cross braces, and foundation anchors. 8. Remove crane. CAUTION Tighten all leg and cross brace hardware before removing crane. Gr 5 hex bolt flat washer flat washer lock washer hex nut hex nut lock washer flat washer leg cross brace flat washer Gr 5 hex bolt Gr 5 hex bolt flat washer leg flat washer lock washer hex nut cross brace Leg and Cross Brace Assembly 15 16 Donaldson Company, Inc. Compressed Air Installation 1. Remove plastic pipe plug from unit s air manifold and connect compressed-air supply line. Use thread-sealing tape or pipe sealant on all compressed-air connections. 2. Install a customer-supplied shut-off valve, bleedtype regulator with gauge, filter, and automatic condensate valve in compressed-air supply line. Note: All compressed-air components must be sized to meet maximum system requirements of 10 to 20 scfm (depending on size of unit) at 90-psi supply pressure. See Specification Control Drawing shipped with unit. Do not increase supply pressure above 100-psi. Component damage can result. CAUTION! The compressed-air supply must be oil and moisture free. Contamination in compressed air used to clean filters will result in poor cleaning, cleaning valve failure or poor collector performance. Purge compressed-air lines to remove debris before connecting to unit s compressed-air manifold. Compressed Air and Component Installation 17 18 Donaldson Company, Inc. Solid-State Timer Installation CAUTION. Turn power OFF during installation or maintenance. Do not install in classified hazardous atmospheres without an enclosure rated for application. The solid-state timer is an electronic timer used to control filter cleaning system. Available options include 3, 6, 10, 20, and 32-pin solenoid valve control. Note: The solid-state timer requires a 105 to 135- Volt customer-supplied power supply. Do not mount solid-state timer on unit. Mechanical vibration can damage control. 1.