deh-p3700mp manual de instalacion
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:deh-p3700mp manual de instalacion.pdf
Size: 1506 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 8 May 2019, 13:43 PM
Rating: 4.6/5 from 685 votes.
Status: AVAILABLE
Last checked: 1 Minutes ago!
In order to read or download deh-p3700mp manual de instalacion ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
deh-p3700mp manual de instalacionEl uso de piezas no autorizadas podria causar fallos de funcionamiento. Para fijar, doble las lenguetas 90 grados.) Tire de la unidad mientras mantiene las her- ramientas presionadas contra los lados de la unidad. The use of unautho- rized parts can cause malfunctions. To secure, bend the tabs 90 degrees.) Keeping the keys pressed against the sides of the unit, pull the unit out. Los colores de los cables de este producto se confor- man con un nuevo codigo de colores. Dieses Produkt entspricht den neuen Kabelfarben. Le code de couleur des cables utilise pour ce produit est nouveau. Questo prodotto e conforme ai nuovi codici colori. De kleuren van de snoeren van dit toestel zijn gewijzigd. Please read through these operating instructions so you will know how to operate your model properly. After you have finished reading the instructions, keep this man- ual in a safe place for future reference. With some applications used to encode WMA head unit.Seek tuning starts as soon as you release the button.Receiving PTY alarm broadcasts RDS (radio data system) is a system for provid- ing information along with FM broadcasts. The preset number may disappear on the dis- other program during an AF frequency play if the tuner tunes in a regional station search.The regional function can be turned on or off the AF indicator flashes. PTY list Specific Type of program NEWS. BMX controls sound reverberations to give playback a fuller You can switch the search method between sound.Pressing again will skip to the pre- vious track. Refer to Repeating play on this page.The first 10 sec- (one-track repeat) and disc repeat. Adjusting loudness Loudness compensates for deficiencies in the low- and high-sound ranges at low volume. Press AUDIO to select LOUD. Press c to select 50 (50 kHz). Press d to se- lect 100 (100 kHz).http://equinox-e.com/upload/UserFiles/file/field-manual-of-diseases-on-trees-and-shrubs.xml
- Tags:
- 1.0.
Switching Auto PI Seek The unit can automatically search for a differ- Initial settings lets you perform initial setup of ent station with the same programming, even different settings for this unit. When you contact your dealer or your nearest. Keep discs out of direct sunlight and do Pioneer Service Center, be sure to record the not expose the discs to high temperatures.The maximum number of characters which rage conditions in the vehicle. Files are compatible with the ID3 Tag Ver. ! This unit plays back WAV files encoded in 1.0, 1.1, 2.2, 2.3 and 2.4 formats for display Linear PCM (LPCM) format or MS ADPCM of album (disc title), track (track title), artist format. The higher the rate, the more information is available to reproduce the sound. Using the same encoding method (such as MP3), the higher the rate, the better the sound. Generally This stands for linear pulse code modulation, speaking CBR (constant bit rate) is more which is the signal recording system used for widely used. But by flexibly adjusting the bit music CDs and DVDs. Lea con detenimiento estas instrucciones sobre el funcionamiento del aparato, para que pueda darle el mejor uso posible.Se pueden reproducir ficheros WMA grabados.Se saltan las carpetas que no.El nivel del volumen del sintonizador de graves.Presione c para seleccionar 50 (50 kHz). Pre- sione d para seleccionar 100 (100 kHz). Bewahren Sie ihn daher an einem sicheren Ort Wiedergabe von MP3-Dateien auf, also keinesfalls im Kraftfahrzeug. Bei eingeschalteter Lokal-Suchlaufabstim- mung erscheint die Angabe LOC im Display. Wenn Sie eine programmierte Station abru- die regionale Programme ausstrahlen. FOLK MUS Volksmusik TA erscheint im Display. Der Tuner ist nun auf L.CLASS Leichte klassische Musik Bereitschaft zum Empfang von Verkehrsdurch- CLASSIC Ernste klassische Musik sagen geschaltet. Im eingebauten CD-Player kann jeweils eine 12-cm- oder 8-cm-Standard-CD (Single) abge- spielt werden.SCAN erscheint im Display.http://gleb777.com/fck_upload/field-manual-of-psychological-operations-fm-33-5.xmlSolche Discs nennt man CD TEXT-Discs.Die Wiedergabe erfolgt in der Reihenfolge der Hinweise Dateinummern. Ordner, die keine Dateien ent-.Bei der manuellen Abstimmung bleibt das Kanalraster auf 50 kHz eingestellt.Registrieren Sie sich jetzt. Please use the box above to search for any other information.When my mp3 player is plugged in the sound quality is not good. Some songs I can hardly hear the vo. (Posted by Jenscontour 6 years ago) Pioneer DEH-P300 Answers The Audio Plug In Back Is For What And The Little Square Plug Near It What Is Th what is the audio plug used for and a little square plug next to it its been sticking out what is it. (Posted by robertnsac 6 years ago) Pioneer DEH-P6700MP Answers How do I take it apart to remove the obstruction. And by having access to our ebooks online or by storing it on your computer, you have convenient answers with Wiring Manual Pioneer Deh P2650. To get started finding Wiring Manual Pioneer Deh P2650, you are right to find our website which has a comprehensive collection of manuals listed. Our library is the biggest of these that have literally hundreds of thousands of different products represented. I get my most wanted eBook Many thanks If there is a survey it only takes 5 minutes, try any survey which works for you. Please upgrade your browser to improve your experience. Qu'ils soient destines pour un rendu des plus pure et de haute resolution ou encore pour une convivialite sans restriction des capacites sans fil du Bluetooth. If the page fails to redirect click here. The thing is the closest thing I found was the DEH-P3700MP but mine doesn't have the Satellite Radio option. Does anyone know if there is a manual for mine. Thank you in advan Find out the most recent pictures of Wiring Diagram Pioneer Eeq Mosfet 50wx4 here, so you can find the picture here simpCD Receiver DEH-P3950MP English Portugues (B) Espanol. Thank you for buying this Pioneer product. After you have finished reading the instructions, keep this man-ual in a safe place for future reference. If you want NextDay, we can save the other items for later. Order by, and we can deliver your NextDay items by. You won’t get NextDay delivery on this order because your cart contains item(s) that aren’t “NextDay eligible”. In your cart, save the other item(s) for later in order to get NextDay delivery. Oops! There was a problem with saving your item(s) for later. You can go to cart and save for later there.A different kind of membership. Learn more Ask a question Ask a question If you would like to share feedback with us about pricing, delivery or other customer service issues, please contact customer service directly. So if you find a current lower price from an online retailer on an identical, in-stock product, tell us and we'll match it. See more details at Online Price Match. Related Pages: Pyle Car Stereos Single Din Car Stereos Bluetooth Car Stereos InstallerNet Satellite Radio Double Din Car Stereos Pioneer Car Stereos Blaupunkt Car Stereos All Rights Reserved. To ensure we are able to help you as best we can, please include your reference number: Feedback Thank you for signing up. You will receive an email shortly at: Here at Walmart.com, we are committed to protecting your privacy. Your email address will never be sold or distributed to a third party for any reason. If you need immediate assistance, please contact Customer Care. Thank you Your feedback helps us make Walmart shopping better for millions of customers. OK Thank you! Your feedback helps us make Walmart shopping better for millions of customers. Sorry. We’re having technical issues, but we’ll be back in a flash. Done. Button(DETACH)Connector(CN651). Antenna Jack(CN401). Holder. HolderSpring. CoverHolder. Terminal(CN402). Button(DETACH)Sheet. Lighting Conductor. Rubber. ConnectorSpring. Spring. Bracket. HolderSee Contrast table(2). CD Mechanism Module(S10.1AACA) CXK5663. ScrewNo. DescriptionDetach Grille Assy. Grille UnitDescription. Part No.Connector(CN101). Connector(CN901). ScrewScrew(M2x3). Screw(M2x3). WasherSpring. SpringSpring. SpringShaft. Frame. FrameBracket. LeverSheet. Collar. Guide. ArmPart No.Gear. Gear. GearArm. RollerArm. DamperArm. GuideArm. Damper. Motor Unit(M1)Screw Unit. Gear Unit. Arm Unit. ArmMotor Unit(M2). Screw(M2x5)Screw. Washer. Pickup Unit(P10)(Service)Spring. ClamperTherefore, when replacing, be sure to use parts ofA-bDecimal points for resistorTherefore, when replacing, be sure to use parts ofNo differentiation is made between chip resistors andSymbol indicates a capacitor. No differentiation is made between chip capacitors andA-a C-bA-a C-bRef.:Normal. Mode. Normal. NormalRef.:Normal. NormalSource On setup operation. Ref.:Normal. NormalSpindle waveform during play operation. Spindle waveform during play operationRef.:Normal. NormalTrack Open waveformRef.:Ref.:Normal. NormalNormal. NormalFor further information forCapacitor. ConnectorP.C.BoardChip Capacitor (except for CQS.)Circuit Symbol and No.Part No.Unit Name:Tuner Amp Unit. Part No.Diode. Diode. DiodeCircuit Symbol and No.Transistor. Inductor. InductorUnit Name:Keyboard UnitUnit Name:CD Core Unit(S10.1)Motor Unit(SPINDLE)If you should mistakenly short the REFO1 with the GNDEspecially on an oscilloscope, avoid connecting the (-)Be sure to set theThis mode is used to adjust the CD mechanism module. While pressing the 4 and 6 keys at the same time, reset. Turn off the ACC and back up. Notes:EJECT key until the loaded disc is ejected. Tracking Servo. ClosePower Off. T.Close and AGC. T.Close. Applicable servomechanism. Applicable servomechanismOperationThe PU unit in the CD mechanismChanging the PU unit is thus best considered as a last resort. However, if the. PU unit must be changed, the grating should be checked using the procedure below. To check that the grating is within an acceptable range when the PU unit is changed. If the grating is off by a large amount symptoms such as being unable to close tracking, being unable to performGrating waveformError is displayed with number for Error cause when CD is inoperative or stops with Error during operation. The purpose is to reduce nonsense calls from users as well as to assist all related analysis and repair for defectsThe same data shall be written in DMIN and DSEC. DTNO is blank asThe following is about LCD display ability.No. Classification ContentsCarriage Home NG. CRG can’t move to the inner. CRG can’t move from the inner. Focus can’t be caught.Focus Search NGSpindle Lock NG. Subcode NG. Not spindle, lock. Wrong subcode (can’t read). Intense vibration. RF-amp NG. The appropriate gain of the RF amp cannot be obtained. Severe vibration. Abnormal CD signals.AGC protection doesn’t work, out of Focus soon. Setup NGImpossible to play. There is no playable MP3 or WMA file present in a disc.File Format NG. Contents are stored in an incompatible file format.Search Time Out. Can’t reach the target address.Impossible to play. There is no playable TRK No.Disc caught in betweenPower NGAbnormal power (failed connector). Note: Error doesn’t display in mechanism only. (CD off causes mechanism off). If TOC can’t be read, error wouldn’t occur, but mechanism still continues its operation. The upper digits of error code is mainly classified by 3 kinds as follows:CD Mechanism ModuleCD Mechanism Module.Grille AssyFig.2Caution: Before installing the carriage mechanism inLower FrameDisconnect the cable.Caution: In assembling, move the planet gear to theSolderChange Arm. Styling Holder. Feed ScrewPlanet GearPin NameModel select input. Not usedDisplay microcomputer communication data output. PLL data input. PLL data output. PLL clock output. Clock adjustment output. Test program input. P-BUS serial data input. P-BUS serial data output. Not used. Display microcomputer chip select output. Illumination power output. CD LSI reset control output. CD LSI command data control output. CD LSI strobe output. CD LSI ceramic oscillator oscillation output. Driver output. Driver control output. Output for dark current reduction circuitNot used. ROM collection data output. ROM collection clock output. ROM collection chip select output. RDS decoder receiving output. VD output. System power output. Wired remote control input. System mute output. Auto antenna control output. E.VOL strobe output. E.VOL data output. E.VOL clock output. PLL chip enable output 2. PLL chip enable output. RDS LK input. RDS clock input. RDS 57K input. Reset. PLL lock detection inputRDS clock input. ACC sense input. Back up sense input. Grille detach sense input. Source sense inputTemperature detection input. VD power supply short circuit input. P-BUS serial pole request input. Wired remote control input(Not used)VrefPin No.LCD segment output. LCD common output. LCD drive power supply. Key strobe output. Key data input (analogue input). Remote control reception input. Display data input. Key data outputCrystal oscillator connection pinNot used. LCD segment output. Power supply. LCD segment outputPin No.Power supply for digital circuits. GND for 1.6V digital circuits. Input of reset. Address bus 12-8 from the microcomputer. Chip selection. Address strobe. Control signals(read). Control signals(write). Control signals(wait). Interruption signals to the external microcomputer. Power supply for 1.6V digital circuits. Power supply for DAC. Output of audio for the right channel. GND for DAC. Connected to the capacitor for band gap. Output of audio for the left channel. Power supply for the crystal oscillator. Connected to the crystal oscillator(16.9344MHz). Ground for the crystal oscillator. Control of 1.6V regulator. Setup 0 for PWM output(SD, MD). Connected to GND. Setup 1 for PWM output(FD, TD). Input of audio data. Output of audio data. Clock input for audio data. Clock output for audio data. Input of LRCK for audio data. Output LRCK for audio data. Permission to oscillate 16.9344MHz. Output of 33.8688MHz(CLK for SDRAM). DRAM cs. Output of DRAM address 11. Output of DRAM CKE. Output of DRAM ras. Output of DRAM lower cas(LDQM). Output of DRAM upper cas(UDQM). Output of DRAM we. Output of DRAM oe(cas). Ground for digital circuits. Output of DRAM address0-10Power supply for digital circuits. Output of spindle drive PWM REFOUT for servo. Power supply for ADC. Output of EFM signals. Input of asymmetry. Analog tests. Input of RF. Ground for the analog system. Output of RF. Connection to the capacitor for detecting 3T. Input of AGC. Output of RF(AGC). Equalizer 2, 1. Reversal input of RF2. Reversal input of RF. Input of A. Input of C. Input of B. Input of D. Input of F. Input of E. Input of reference voltage. Power supply for the analog system. Output of reference voltage. Connected to the capacitor for output of REFOUT. I get my most wanted eBook Many thanks If there is a survey it only takes 5 minutes, try any survey which works for you. But this one is kind of more of my thing. Very convenient unlike the other sites, no pop-up windows or redundant pics. Services: Sync music, Manage music, Recover missing metadata, Record CDs Download MediaMonkey Now Buy MediaMonkey Gold Get Addons Never use any other conversion tool again. Glom inte: las alltid instruktionsboken innan du koper nagot! Lastmanuals erbjuder dig snabb och enkel tillgang till PIONEER DEH-P3600MP instruktionsboken Vi hoppas att den har PIONEER DEH-P3600MP manualen blir till nytta for dig Lastmanuals kan inte pa nagot satt hallas ansvarigt for att det dokument du soker saknas, ar inkomplett, pa ett annat sprak an ditt eget eller om modellbeteckning eller sprak inte stammer med beskrivningen. Lastmanuals tillhandahaller ingen oversattningsservice. Klicka pa ”Ladda ner manualen” i slutet av texten for att godkanna anvandarvillkoren. Nedladdningen startar genast. DEH-P3600MP WMA-MP3-WAV CD RDS Tuner. Overview; Add in D4Q for perfect radio reception and Pioneer's MOSFET 50 W x 4 power amp with EEQ for customised power sound. Pioneer deh- p3600mp. This feature not only saves the cost of an external power supply, but also greatly simplifies wiring. In addition, there is a second 40 mA power supply provided with the 4-20 mA output option, evident also in the above diagram. The picture above illustrates several other reasons why the ProVu is the only process meter you will ever need. First off, is the NEMA 4X rated front panel which means you can install the ProVu in panels exposed to moisture, dust and other adverse conditions. The picture also points out that the ProVu is available with an optional Sunbright display which means you can install and read the ProVu in direct sunlight. The next thing to notice is the 6-digit dual-line display that can display numbers up to 999,999 on the upper line and show either a tag or the input in a different scale on the lower line. Other key features include four relays and 4-20 mA output option, advanced signal input conditioning like automatic round horizontal tank linearization, function keys, pump alternation capability, and Modbus RTU serial communications. Finally all these features and capabilities can easily be programmed with free MeterView Pro PC-based software. This feature saves money by eliminating an external power supply and also simplifies wiring by reducing the number of devices in the loop. It can be configured for 5, 10, or 24 V (default) by means of a simple internal jumper. To use an external power supply instead of the internal power supply, simply make connections to different terminals on the ProVu. Resettable Fuse Prevents Current Overload Another very useful aspect of the ProVu is that the current input is protected against current overload by a resettable fuse. The fuse limits the current to a safe level when it detects a fault condition, and automatically resets itself when the fault condition is removed. Other Uses for the Transmitter Power Supplies The most common use for these two power supplies is for the 200 mA transmitter power supply to power the field transmitter and 40 mA power supply to power the 4-20 mA output from the meter. However, since these two power supplies are isolated they can be used in other ways. For instance, some level transmitters require the use of a heated lens. The ProVu’s 200 mA power supply could be used to power the heated lens and ProVu’s 40 mA power supply could be used to power the 4-20 mA input. ProVu Powers Both Heater and 4-20 Output External Power Supply for the Loop For applications that require an external transmitter power supply, the same ProVu is used and merely wired in a different fashion as the following diagrams illustrate: PDA1024-01 24 VDC Transmitter Power Supply Precision Digital offers the PDA1024-01 for applications that require more than the 200 mA power that the ProVu can provide. The lower display can be configured to display engineering units, set points, user defined messages, or simply turned off. The ProVu’s dual-line display makes all the difference both when programming the instrument and when using it in the field. When programming the instrument, the dual line display prompts for the needed information and also helps you keep track of where you are in the setup process. When using the instrument, the dual line display provides more information such as displaying the input in two different scales like height and volume for a level application. We call this the Dual-Scale feature. Programming Assistance The ProVu’s dual-line display makes programming the instrument much easier because the lower line prompts for the needed information and also helps you keep track of where you are in the setup process. The ProVu is prompting for the value for Input 2 and displaying the default value of 20.00 mA. The “2” in 20.00 is brighter than the rest of the digits indicating that it is the number that will be changed by the Up and Right arrows. The ProVu is now prompting for what the user wants Display 2 to be; that is the value that corresponds to 20 mA. However, for direct sunlight exposure the ProVu is available with super-bright LEDs that make it possible to read the ProVu even in direct sunlight. Both versions of the ProVu have eight levels of adjustable intensity. Rounding Feature for Even Steadier Display The rounding feature is used to give the user a steadier display with fluctuating signals. It causes the display to round to the nearest value according to the rounding value selected (1, 2, 5, 10, 20, 50, or 100). For example, with a rounding value of 10, and an input of 12346, the display would indicate 12350. Dual-Scale Display Feature The PROVU PD6000 has a rather unique, and very flexible dual-scale capability. MeterView Pro is resident on the ProVu and is accessed by a provided USB cable, so it is by far the easiest way to program the ProVu. The ProVu can be calibrated either by applying a known signal or scaled by entering a desired value with the front panel buttons or MeterView Pro software. Most customers will use the scaling method because it is simpler and does not require a calibrated signal source. Selecting the input to be current or voltage is done with the front panel buttons or MeterView Pro software. Once programming is completed it can be locked with a password. This eliminates the need to insert CDs, install drivers, or download software from the internet. When you connect your ProVu to your PC, MeterView Pro is downloaded to your PC, the software automatically selects the model you are programming, and you’re ready to start programming immediately. Further simplifying the programming process, the ProVu can be powered from the USB port, so no need to apply external power while programming your meter. In addition to programming, the software will also allow you to monitor, and datalog a ProVu using your PC. You can also generate and save programming files for later use. Send Meter Data: Clicking this button, sends current MeterView programming to the meter. The configuration file can be sent or retrieved from the directory of your choice. This makes it very easy to program multiple meters with the same programming. It is also a great backup utility as well. While the output is nominally 4-20 mA, the signal will accurately accommodate under- and over-ranges from 1 to 23 mA. The 4-20 mA output can be reversed scaled such that 4 mA represents the high value and 20 mA represents the low value. For instance, a 4-20 mA output signal could be generated as the meter went from 100.0 to 0.0. For applications where the input was linearized by the ProVu, the 4-20 mA output will represent that linearized value. Connections The ProVu can provide 40 mA at 24 VDC to power the 4-20 mA output signal or an external power supply can be used: The internal 24 VDC power supply powering the analog output may be used to power other devices, if the analog output is not used. The 4-20 mA output can either be programmed using the front panel push buttons or free MeterView Pro software. Front Panel Push Button Programming The 4-20 mA analog output can be scaled to provide a 4-20 mA signal for any display range selected. No equipment is needed to scale the analog output; simply program the display values to the corresponding mA output signal. The Analog Output menu is used to program the 4-20 mA output based on display values. MeterView Pro Software Programming When a meter is programmed as shown below, the output will be 4.00 mA when the display reads 0 and the output will be 20.00 mA when the display reads 150000. One such application would be pump control using the ProVu’s relays in pump alternation mode. The ProVu can be equipped with up to four 3 A Form C (SPDT) internal relays and an additional four more 3 A Form A (SPST) external relays. Setting a set point above a reset point results in a high alarm and setting a set point below a reset point results in a low alarm. Resetting the Relays (Action in MV Pro) All relays are independent of each other and may be programmed to reset (Action in MV Pro) in the following ways: Automatic: Alarm will reset automatically once the alarm condition has cleared. Latching: Alarm must be reset manually and can be done so at any time. Latching with Reset after Cleared: Alarm must be reset manually and can only be done so after the alarm condition has cleared. Each relay on the ProVu can be programmed with independent on and off time delays of 0 to 999.9 seconds to achieve this. Relays Auto Initialization When power is applied to the meter, the front panel LEDs and alarm relays will reflect the state of the input to the meter. Signal Loss or Loop Break Relay Operation When the meter detects a break in the 4-20 mA loop, the relay will go to one of the following selected actions: Turn On (Go to alarm condition) Turn Off (Go to non-alarm condition) Ignore (Processed as a low signal condition) User Selectable Fail-Safe Operation All relays are independent of each other and may be programmed for user selectable fail-safe operation. With the fail-safe feature activated, the relays will transfer to the alarm state on power loss to the meter. Front Panel LEDs The meter is supplied with four alarm points that include front panel LEDs to indicate alarm conditions. This standard feature is particularly useful for alarm applications that require visual-only indication. Manual Output Control Take control of any output with this feature. All relays can be forced ON or OFF, and the 4-20 mA output signal can be set to any value within its range. When the relays and 4-20 mA output are controlled manually, an LED labeled “M” is turned on and the associated Alarm LEDs (1-8) flash every 10 seconds indicating that the meter is in manual control mode. Sampling Function (PV Triggered Timed Relay) The sampling function allows the operator to set a relay as a “sampling” relay. When the batch reaches a certain pH, the relay contacts would close and by some means (light, horn, etc.) alert someone to take a sample, or provide the trigger to automatically take a sample of the batch. The utility of this function can, of course, be expanded beyond sampling and be used whenever a timed relay output closure is required when the PV reaches a certain set point. Interlock Relay(s) This function allows a process to use one or more very low voltage input signals or simple switch contacts to control the state of one or more internal “interlock” relays. One input can be used in series with a number of interlock switches, or up to eight inputs can be required to force-on one (or more) internal interlock relays. Please see ProVu Series Safety Interlock Feature whitepaper on our website for more information. Switching Inductive Loads The use of suppressors (snubbers) is strongly recommended when switching inductive loads to prevent disrupting the microprocessor’s operation. The suppressors also prolong the life of the relay contacts. Precision Digital offers the PDX6901. Multi-Pump Alternation The ProVu can be used as a pump controller when combined with a continuous level transmitter. Click here for more information Back to top Signal Input Conditioning There are many applications in the industrial world that can’t be satisfied with simple, two-point linear scaling so the ProVu has advanced linearization capabilities to handle applications like round horizontal tank volume measurement, open channel flow, DP flow, and others. And all of these capabilities are easily programmed using MeterView Pro programming software. 32-Point Linearization The most common way to linearize a non-linear signal is to break it up into smaller ranges that are more linear than the overall range. The ProVu is available with up to 32 points of linearization and if dual scale feature is used, the second PV can have up to eight points of linearization. The linearization data can be imported from an Excel spreadsheet or can be exported from MeterView Pro to an Excel spreadsheet.