bosch lbb 1956 installation manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:bosch lbb 1956 installation manual.pdf
Size: 1453 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 15 May 2019, 16:29 PM
Rating: 4.6/5 from 746 votes.
Status: AVAILABLE
Last checked: 9 Minutes ago!
In order to read or download bosch lbb 1956 installation manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
bosch lbb 1956 installation manualYou must have JavaScript enabled in your browser to utilize the functionality of this website. Please contact us for up to the minute pricing and advice on product suitability for your project. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below. User-Friendly Manuals. Product Instructions. The Bosch solution brings state of the art video surveillance to CMS while greatly reducing the costs and risks associated with new technology deployments. Already field-proven in Europe, Bosch now makes these services available through central monitoring stations in the Americas.There is significant opportunity for central monitoring stations to create new revenue opportunities by solving this business need for their customers.?Selecting the proper imaging technology up front will be one of your most important decisions you will face designing and implementing your network video project. When considering compression options for network video solutions, the following video related issues should be reviewed and carefully considered. Minimum Resolution. Image Quality. Minimum and Maximum Frame Rates (FPS). Number of Cameras (Scalability). Storage Requirements. Available Bandwidth. Overall Latency (time difference between live and displayed video). Budget. The compression logic used in both MJPEG, MPEG4 and H.264 are beyond the scope of this white paper. Suffice it to say that MJPEG, MPEG4 and H.264 compression algorithms are the most common forms of video compression currently used in the network video industry.With 3,280 feet (1 kilometer) of recognition-level imaging and 3,937 feet (1,200 meters) of classification-level imaging. Plena Security System pdf manual download. With release 3.0 of the Plena Voice Alarm, Bosch ensures full EN 54 compliance, extended zoning, windows compliant and on-line system design. System hardware installation.http://www.chaine.si/files/bravo-ii-autoprinter-manual.xml
- Tags:
- bosch lbb 1956 installation manual, bosch lbb 1956 manual, bosch lbb 1956 installation manual, bosch lbb 1956 installation manual pdf, bosch lbb 1956 installation manual download, bosch lbb 1956 installation manual free, bosch lbb 1956 installation manual online.
Checking your browser before accessing This process is automatic. Your browser will redirect to your requested content shortly. The product specifications are provided by manufacturers. Enter Details for faster checkout. It can make calls to selected zones (one to six and all-call) in a public. Free delivery and returns on eligible orders. For more information or to request a quotation please complete our Quotation Request Form or email us with your request. It is the basis of the Plena Voice Alarm System, and has all the essential functionality for compliance with the IEC standard, including full system supervision, loudspeaker line impedance. This high-performance unit fulfills a wide range of public. A click sounds lbb 1956 00 user manual through the loudspeakers at regular intervals Password not working Configuration download fails Can’t retrieve the original wave files with the configuration download Downloads. A member of our Bosch team lbb 1956 00 user manual will contact you immediately regarding your enquiry. It has the same stable metal base as the call station. The Plena Voice Alarm Router is an expansion unit that. Plena Security System pdf manual download. There is a pinout printed on the pcb but I am confused because there. The call station has a balanced line level output, making it. Bosch Voice Alarm. Installers and users of extensive systems should refer to the Installation and User Instructions (see section ). It provides 3 short protected DCN trunk outputs. Download brochure;. You must be logged in to post a review. Up to eight keypads can be added with each keypad adding seven zone or zone-group keys. Also find here related product comparison. LEDs on the front panel show the status of the amplifier: power, audio output level, and supervised functions. Does anybody have a manual or a schematic. Please lbb 1956 00 user manual complete the following form with as much information as you have available and click submit.https://liana-mebel.ru/files/fckeditor/bravo-ii-autoprinter-manual.xml Each message can have any length within the total available capacity. Page Count: 3. It is the basis of the Plena Voice Alarm System, and has all the essential functionality for compliance with the EN and 54?16 standards, including full system supervision, loudspeaker line impedance supervision, a supervised emergency microphone on the front panel and a supervised message manager. Plena voice alarm system: The Plena voice alarm system is designed for public address and emergency evacuation in small to medium sized applications, such as factories, offices, shopping malls, supermarkets, sports facilities, schools and universities. Subject to credit approval. The product functions and specifications are subject to change without prior notice. Bosch Praesideo call station equipment Click to view more information about each component. The product portfolio includes video surveillance, intrusion alarm, fire alarm and voice evacuation systems as well. This call station features selectable gain, a selectable speech filter, and a limiter for improved intelligibility.Alarm System Controller. Get best deals for coconut. Product prices are subject to change without prior notice. It can use the built-in amplifier on the. Bosch Security Systems is a leading global supplier of security, safety, and communications products, solutions and services. The Plena (VAS) Voice lbb 1956 00 user manual Alarm System range is an ideal evacuation, message and background music solution for small to medium sized applications in a variety of locations, such as schools, hotels, shopping centers, factories, offices and. eks. The Installation and Operation manual is intended for installers and users of an (extensive) Plena Voice Alarm System. Stylish six-zone lbb 1956 00 user manual call station for the Plena Voice Alarm System; Six zone selection keys, all-call key and momentary PTT-key for calls; Selectable gain, speech filter, limiter, and output level for improved intelligibility.http://eco-region31.ru/3m-dx70-manual The keypad comes equipped with seven additional zone select keys. All Plena Power Amplifiers in this manual are designed for use in EN54?16 and EN compliant systems. Also find here related product comparison. The following page brings together every PDF download available on our website.LBB 00 Plena Voice Alarm Call Station Data Sheet EnUS - Free download as PDF File. The Plena Voice Alarm Controller is the heart of the voice alarm system. Plena Voice Alarm System Call Station, 6-Zone, Standalone Mounting, lbb 1956 00 user manual 24 Volt lbb 1956 00 user manual DC, 30 Ampere, 85 dB, Charcoal with Silver. It can make calls to selected zones one to six and all-call in a public address system built with the Plena Voice Alarm System. It has a metal base that provides you increased stability while using. Alarm System. Intentional or. In the event of PC failure, the CCU reverts to a default. A fully equipped system contains a PLENA matrix processor, 2 PLENA matrix amplifiers, 8 call stations and 16 wall. Flexible microphone stem and a unidirectional condenser microphone, metal base design, can make calls to selected zones (one to six and all-call): Stylish six zone call station for the Plena Voice Alarm System. It can make calls to selected zones (one to six and all-call) in a public address system built with the Plena. The board monitors the integrity of a loudspeaker line. Related products. 1 10 interference in which case the user will be required to correct the interference at his own expense. In lbb 1956 00 user manual addition to tabletop use, the special design allows it to be lbb 1956 00 user manual neatly flush-mounted in desktops. Our team of Bosch experts will be happy to help you. It can make calls to selected zones (one to six and all-call) in a public address system built with. Additionally, single channel operation is possible with only one Plena amplifier.http://curabona.com/images/bosch-lifestyle-automatic-dishwasher-manual.pdf Multiple routers can also share one amplifier, including the internal amplifier on the controller unit. It is possible to use any number of amplifiers from one up to the number of routers used.The messages can be merged to allow even more flexible use of pre-recorded announcements and evacuation messages. The controller can be used as a stand-alone system with up to six zones or expanded to up to 120 zones using additional six-zone routers. Up to eight call stations can be connected. Interconnections are made using standard RJ45 connectors and shielded CAT-5 cable. A built-in 240 W amplifier provides the power for the emergency call channel and BGM. Additional Plena Amplifiers can be added to provide two-channel operation. All amplifiers are supervised. The audio output uses standard analogue audio 100 V line switching for full compatibility with the Plena family of public address equipment and Bosch EVAC-compliant loudspeakers. The system is configured using DIP switches for basic functionality and a PC for more advanced functions. A total of 16 priority levels can be specified for the microphone, call stations and trigger inputs for optimum system flexibility. The powerful 240 W output section has six transformer-isolated 100 V constant-voltage outputs for driving 100 V loudspeakers in six separate zones. The 100 V-technique reduces line losses on longer distances and provides easy parallel connection of multiple loudspeakers. All zones may be individually selected from the front panel, and the BGM output level in each zone can be individually set in six steps. Configuration software is provided on the CD included with the unit. The CD also includes many useful programs, such as MP3-ripping software, a sample- rate converter, various audio and visual tools, and free, MP3-coded music. The amplifier output is also available as a separate output on 100 V and 70 V. A separate 100 V call-only output provides addressing for an area where BGM is not required but where priority announcements are. Six configurable volume-override output contacts are available for overriding local volume controls during priority calls. Both four-wire and three-wire schemes are supported. An LED meter monitors the output. Controls and indicators: Front: In addition to tabletop use, the special design allows it to be neatly flush mounted in desktops.Up to eight keypads can be added with each keypad adding seven zone or zone-group keys. This call station features selectable gain, a selectable speech filter, and a limiter for improved intelligibility. The call station has a balanced line-level output, making it possible to position it up to 1000 meters from the controller, using CAT-5 extension cables. With shielded cable, the call station can also be used in an EMC level 5 (heavy industry) environment. DIP switches at the base of the call station select different microphone gain levels, the call station ID, and the speech filter. A service accessible rotary control provides microphone level attenuation. LEDs on the call station show which zones have been selected. Three additional LEDs give visible feedback on the active state of the microphone and the system. Green flashing means standby (chime is sounding). Green indicates microphone active. Amber indicates that the system has detected a fault, and red indicates that the system is in the emergency state. Controls and indicators: Four status LEDsPTT-key PTT status LED Six zone selection keys Six zone selection LEDs All-call key Eight DIP switches Rotary volume control Interconnections: Two RJ45 jacks 24 VDC input Keypad connector It can provide dual channel operation for simultaneous calls and BGM for up to six different zones, using two Plenaamplifiers. Features: All Rights Reserved ( Terms of Use ) Developed and Managed by IndiaMART InterMESH Limited. It is a system that assists in the effective evacuation of an area or building during a fire, bomb alert or other emergency. At all other times a voice alarm system is used to make public address announcements, broadcast advertisements or background music. All broadcasts, be they live announcements or continual music, can be sent to all areas of a site or to selected areas (referred to as zones). Research has proven that in an emergency people will react without confusion or panic if they receive a clear, intelligible message. These messages are stored within a voice alarm system. A voice alarm system provides clear easily understood instruction via pre-recorded messages. This method ensures that even untrained personnel and the general public are evacuated speedily and efficiently. Interested in this product? The controller can be used as a stand-alone system with up to six zones, or expanded to up to 120 zones using additional six-zone routers. Up to eight call stations can be connected.Interconnections are made using standard RJ45 connectors and shielded CAT-5 cable. The audio output uses standard analog audio 100 V line switching for full compatibility with the Plena family of public address equipment and Bosch EVAC-compliant loudspeakers. The system is configured using DIP switches for basic functionality and a PC for more advanced functions.It can provide dual channel operation for simultaneous calls and BGM for up to six different zones, using two Plena amplifiers.In addition to tabletop use, the special design allows it to be neatly flushmounted in desktops.In addition to tabletop use, the special design allows it to be neatly flush-mounted in desktops.A PC uploads messages and configurations via RS-232 to the unit, which can then operate without a PC. The standard WAV format is used for messages with sample rates of 8 kHz to 24 kHz with 16-bit word length (linear PCM). This gives up to 500 seconds of recording time with a CD???quality signal-to-noise ratio. The unit has 12 contact closure trigger inputs for announcements. Each can be configured for a sequence of up to four messages from those available. In this way messages can be used in combination with other messages, optimizing flexibility and storage space usage. Continuous activation of a trigger input causes the corresponding message sequence to repeat. Use shielded cable (CAT-5) between the routers and the controller. The factory default setting of the Plena Voice Alarm System Controller is as follows: One channel system. Supervision off. Please read the latest release notes for the version of the hardware and software you are using. With firmware (e.g ), the first digit is a major release, where backward compatibility is not guaranteed, second digits are changes in functionality that are backward compatible, the last digits are for bug fixes without impact on functionality. Lastly, the PC configuration software may have an Rx suffix, that indicates changes to the PC configuration software without changes to firmware V2.0 Installation and Operation manual Bosch Security Systems B.V. 9 Plena About this manual en About this manual Purpose of this manual The purpose of the Installation and Operation manual is to provide information that is required to install, configure and operate a Plena Voice Alarm System. 2.2 Intended audience The Installation and Operation manual is intended for installers and users of an (extensive) Plena Voice Alarm System. 2.3 Related documentation The following related document is available: Plena Voice Alarm System Configuration Software Manual. Refer to the product related information on Alerts and notice signs Four types of signs can be used in this manual. The type is closely related to the effect that may be caused if it is not observed. These signs - from least severe effect to most severe effect - are: Notice. Containing additional information. Usually, not observing a notice does not result in damage to the equipment or personal injuries.!! Caution! The equipment or the property can be damaged, or persons can be lightly injured if the alert is not observed. Warning! The equipment or the property can be seriously damaged, or persons can be severely injured if the alert is not observed. Danger! Not observing the alert can lead to severe injuries or death. Bosch Security Systems B.V. Installation and Operation manual V2.0 10 10 en About this manual Plena 2.5 Conversion tables In this manual, SI units are used to express lengths, masses, temperatures etc. Application areas The application areas of the Plena Voice Alarm System include: Supermarkets, shops Factories High-rise buildings Office buildings Schools Recreational facilities Hotels Small airports Plena The Plena Voice Alarm System is part of the Plena product range. Plena provides public address solutions for places where people gather to work, worship, trade or simply enjoy themselves. It is a family of system elements that are combined to create public address systems tailored for virtually any application. The range includes mixer, pre, system and power amplifiers, a source unit, digital message manager, feedback suppressor, conventional and PC call stations, an All-in-One system, an audio interface, a timer, a charger, a loop amplifier, a BGM source and a voice alarm system. Each element is designed to complement all others thanks to matched acoustical, electrical and mechanical specifications. Praesideo It is possible to combine the Plena Voice Alarm System with e.g. a Praesideo digital public address and emergency sound system, or a Promatrix or other system. When an audio output of Praesideo is connected to a VOX audio input of the Plena Voice Alarm System, calls that are made by the Praesideo system overrule the calls that are made with the Plena Voice Alarm System V2.0 Installation and Operation manual Bosch Security Systems B.V. 13 Plena System overview en Voice Alarm Controller The Voice Alarm Controller is the heart of the Plena Voice Alarm System. The voice alarm controller distributes emergency calls, business calls as well as background music (BGM) to up to 6 loudspeaker zones. Figure 3.1: Voice Alarm Controller Notice. When the voice alarm controller has been purchased in the Asian-Pacific Region, the emergency button has a different cover Hand-held microphone The voice alarm controller is equipped with a hand-held microphone, which can be used to make emergency calls. Internal power amplifier The voice alarm controller has a 240 W internal power amplifier, which can be used in 1 channel or 2 channel mode. In the 1 channel mode, all calls and BGM are amplified by the internal power amplifier. If desired, an external power amplifier can be connected for spare switching. In the 2 channel mode, the BGM is amplified by the internal power amplifier, whereas the calls are amplified by an external power amplifier. Internal message manager The voice alarm controller has an internal message manager, which maps wave files (.wav) to messages that can be played by the Plena Voice Alarm System. Supervision All necessary supervision features for compliance to evacuation standards are integrated into the voice alarm controller. If supervision is enabled and a fault is detected, the voice alarm controller lights a LED on its front panel that indicates the cause of the fault. Trigger inputs The voice alarm controller has a terminal block to which 6 emergency (EMG) and 6 business trigger inputs can be connected. Third party systems can use the trigger inputs to start emergency and business calls in the Plena Voice Alarm System. Bosch Security Systems B.V. Installation and Operation manual V2.0 14 10 k 10 k N en System overview Plena Remote control With the Voice Alarm Remote Control, it is possible to control the voice alarm controller from another site. The remote control is also available as kit (Voice Alarm Remote Control Kit) for creating customized solutions. The maximum number of remote controls that can be connected to the voice alarm controller is 2. A special type of remote control is the Fireman s Panel. The green power LED is lit if the voice alarm controller is connected to the mains or back-up power and switched on. The VU meter indicates the master VU level: 0 db (red), 6 db, -20 db (yellow). Notice: As the pilot-tone level of the VAS is -20 db or -23 db in some amplifiers, the -20 db LED will be on continuously. Fault indication is only possible if supervision is enabled (see section Fault indicators, page 98). If supervision is disabled, the yellow Disabled LED is lit. 3. Fault state buttons: Two buttons to acknowledge (Ack) and reset (Reset) the fault state (see section Fault State, page 96). 4. Emergency state buttons: Two buttons to acknowledge (Ack) and reset (Reset) the emergency state (see section Emergency state, page 91). 5. Emergency call zone selectors: Six buttons to select the zones to which the emergency call must be distributed (see section Emergency state, page 91). Each button has a green and a red LED. The six red LEDs indicate the zones that are selected for the emergency call. The six green LEDs indicate the zones in which a business call is running. 6. BGM zone selectors: Six buttons to select the zones to which the BGM is distributed (see section Background music, page 88). Each button has a green LED and a rotary knob. The six green LEDs indicate the zones to which BGM is distributed. The six rotary knobs are local volume controls that can be used to adjust the volume of the BGM in each zone. The selected source is indicated with a green LED (see section Background music, page 88). 9. BGM tone controls: Two rotary knobs to control the high and low frequencies of the BGM (see section Background music, page 88). 10. All call button: A button to select all zones. This button is only available in the emergency state (see section Emergency state, page 91). 11. Indicator test button: A button to test all LEDs on the front panel of the voice alarm controller, and connected voice alarm routers, remote control panels, remote control extensions and fireman s panels. All LEDs are lit as long as the button is pushed (see section Fault State, page 96). 12. Emergency button: A push button to put the system in the emergency state (see sectionemergency state, page 91). 13. Alert message button: A button to select the alert message. This button is only available in the emergency state (see section Emergency state, page 91). 14. Alarm message button: A button to select the default alarm message. This button is only available in the emergency state (see section Emergency state, page 91). Bosch Security Systems B.V. Installation and Operation manual V2.0 16 16 en System overview Plena 15. Microphone socket: A socket to connect the hand-held emergency microphone (see section Emergency microphone, page 49). 16. Bracket: A bracket for the hand-held emergency microphone that is supplied with the voice alarm controller. 17. Monitoring speaker: Built-in monitoring speaker. 18. Zone outputs: Six zone outputs to connect loudspeakers to the voice alarm controller. Do not change the positions of the switches. 24. Calibration switch: A switch to calibrate the impedances of the loudspeaker lines for loudspeaker supervision (see section Calibration, page 87). 25. Configuration settings: A set of DIP switches to configure the system (see section System settings, page 75). 26. PC socket: A USB socket to connect the voice alarm controller to a PC. The VOX settings are configured with the DIP switches and the source switch (see section VOX configuration, page 81). 39. PC Call station input: An input to connect a PC call station. For future use. 40. BGM inputs: Two inputs to connect background music sources. Each input consists of two cinch sockets (see section BGM inputs, page 60). 41. Line output: A line output to connect an external recording device to record the audio of the Plena Voice Alarm System (see section Line output, page 58). 42. External power amplifier (output): An XLR socket to connect an external power amplifier (see section External power amplifier, page 52). This socket is used in combination with the external power amplifier input (no. 47). 43. Trigger outputs: Two general purpose trigger outputs. For future use. TR1 is active during impedance check. 44. Internal power amplifier output: Three pins that provide the 100 V audio signal of the internal power amplifier of the voice alarm controller. Also includes a 70 V connection. 45. Call output: An output that provides the call audio of the Plena Voice Alarm System. 46. Back-up power inlet: An inlet to connect a back-up power supply to the voice alarm controller (see section Power, page 62). 47. External power amplifier (input): An input to connect an external power amplifier (see section External power amplifier, page 52). These pins are used in combination with the external power amplifier output (no. 42). Bosch Security Systems B.V. Installation and Operation manual V2.0 18 18 en System overview Plena 3.3 Voice Alarm Router With the Voice Alarm Router, the number of loudspeaker zones and trigger inputs in the system can be increased. Figure 3.3: Voice alarm router Loudspeaker zones A voice alarm controller can serve and manage 6 loudspeaker zones. To increase the number of zones in the system, one or more Voice Alarm Routers can be connected to the voice alarm controller. Each router adds a maximum of 6 zones to the system. As the maximum number of voice alarm routers that can be connected in a system is 19, the maximum number of zones in a Plena Voice Alarm System is 120 (from hardware and software version 3.x onwards). Notice! If older routers are used (version 2.x or higher), 60 zones can be addressed. The recommendation is to always use 3.x hardware in combination with each other Trigger inputs A voice alarm controller can manage 6 emergency (EMG) and 6 business trigger inputs. To increase the number of EMG and trigger inputs, one or more voice alarm routers can be connected to the voice alarm controller. Each router adds a maximum of 6 EMG trigger inputs and 6 business trigger inputs to the system. As the maximum number of voice alarm routers that can be connected in a system is 19, the maximum number of EMG trigger inputs in a Plena Voice Alarm Systemis 120 (from hardware and software version 3.x onwards). The maximum number of business trigger inputs in a Plena Voice Alarm System is also 120 (from hardware and software version 3.x onwards). Notice! If older routers are used (version 2.x or higher), 60 zones can be addressed. The recommendation is to always use 3.x hardware in combination with each other External power amplifiers The voice alarm router does not have an internal power amplifier. When the power that is supplied by the voice alarm controller is insufficient, to each voice alarm router two external power amplifiers can be connected. In a multi router system, multiple power amplifiers can be connected to amplify calls and background music (BGM) or just for backup purposes. Remote control With the Voice Alarm Remote Control Extension, it is possible to control the voice alarm router from another location. The green power LED is lit if the voice alarm router is connected to the mains or back-up power and switched on. Fault indication is only possible if supervision is enabled (see section Fault indicators, page 98). 3. Emergency call zone selectors: Six buttons to select the zones to which the emergency call must be distributed (see section Emergency state, page 91). The six green LEDs indicate the zones in which a business call is running. 4. BGM zone selectors: Six buttons to select the zones to which the BGM is distributed (see section Background music, page 88). Each button has a green LED. The six green LEDs indicate the zones to which BGM is distributed. 5. Zone outputs: Six zone outputs to connect loudspeakers to the voice alarm router. Each zone output consists of two loudspeaker line outputs (see section Loudspeakers, page 66). Bosch Security Systems B.V. Installation and Operation manual V2.0 20 20 en System overview Plena 6. External power amplifier 1 (input): An input to connect an external power amplifier (see section External power amplifiers, page 67). For future use. 23. Back-up power inlet: An inlet to connect a back-up power supply to the voice alarm router (see section Power, page 68). 24. External power amplifier 2 (input): An input to connect an external power amplifier (see section Voice Alarm Router, page 109). These pins are used in combination with the external power amplifier output (no. 18) V2.0 Installation and Operation manual Bosch Security Systems B.V. 21 Plena System overview en Call Station The Call Station can be connected to the Plena Voice Alarm System to make business calls. The maximum number of call stations in a Plena Voice Alarm System is 8. Figure 3.5: Call Station Buttons Each call station has zone select buttons and a push-to-talk (PTT) button. The zone select buttons can be configured for selecting zones and zone groups in the system. To the PTT button, a pre and post chime can be assigned that is played at the start or at the end of the business call. Supervision The call station is not supervised. For compliance to evacuation standards, the Plena Voice Alarm System disables the call station during emergency calls. Bosch Security Systems B.V. Installation and Operation manual V2.0 22 22 en System overview Plena Keypad Each voice alarm router can add 6 extra loudspeaker zones to the system.