3ware 9690sa manual
LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF
File Name:3ware 9690sa manual.pdf
Size: 2736 KB
Type: PDF, ePub, eBook
Category: Book
Uploaded: 29 May 2019, 15:56 PM
Rating: 4.6/5 from 597 votes.
Status: AVAILABLE
Last checked: 1 Minutes ago!
In order to read or download 3ware 9690sa manual ebook, you need to create a FREE account.
eBook includes PDF, ePub and Kindle version
✔ Register a free 1 month Trial Account.
✔ Download as many books as you like (Personal use)
✔ Cancel the membership at any time if not satisfied.
✔ Join Over 80000 Happy Readers
3ware 9690sa manualUsing an incorrect cable can result in drives that are not detected. These cables have multi-lane cable plug connectors on each end (Figure 6). Figure 6. If you are uncomfortable opening a computer system and conforming to standard ESD (electrostatic discharge) practices, you should have a computer technician perform the installation. Replacing the heat sink will alter thermal characteristics and cooling requirements and may cause the controller to fail. Replacing the factory-installed heat sink will void the warranty. The on-board heat sink collects heat, and must have adequate airflow in order to disburse it. It is important that the cables do not obstruct the air flow or prevent proper ventilation of the system. If your enclosure is low-profile, unscrew the full height bracket from the 3ware 9690SA RAID controller and replace it with the included low-profile bracket, using the same screws. If appropriate, set the PM2 (power management) jumper on the disk drives, to enable staggered spinup. Save this screw; it will be used to secure the 3ware 9690SA RAID controller after you have seated it in the slot. Position the card in the PCI Express slot so that the contacts will mate with the grooves in the slot, and all pins make proper contact with the PCI Express slot pins when pushed into place. Check that the 3ware RAID controller’s metal bracket covers the hole in the case and secure the bracket with the screw that was used to secure the filler bracket in step 5. Insert the SFF-8088 cable plug connector into the multi-lane external connector of the controller. When the plug is inserted correctly, you will feel it click into place. The user guide is included on the 3ware CD that came with your controller.When used with the 3ware 9690SA RAID controller, the BBU control module is mounted on the RAID controller and the battery pack is installed on a remote battery board. If you have a 9690SA-8E the location of the control module post hole will be different.http://kleiberit.ru/files/bosch-instruction-manuals-to-download.xml
- Tags:
- 3ware 9690sa-8i manual, 3ware 9690sa manual, 3ware 9690sa manual download, 3ware 9690sa manual pdf, 3ware 9690sa manuals, 3ware 9690sa manual free.
Remove the screw head from the plastic post on the BBU control module and set it aside (you will reattach it soon.) Figure 11. The battery can be mounted in 3 different positions, as marked on the board (see Figure 14). Use the position that will make it easiest to connect the battery power cable to the BBU control module on the 3ware RAID controller. Press down on the top of the battery module to free the clip on the bottom of the module. While pressing down on the top of the battery module, lift out the bottom of the battery module slightly. AMCC also offers toll-free 1 (800) 840-6055 or 1 (858) 535- 6517 direct phone support during normal business hours. This publication may be copied or reproduced for reference purposes only. All other purposes require the express written consent of AMCC, 215 Moffett Park Drive, Sunnyvale, CA 94089.Chapter Description 1 Getting Started Overview of the 3ware RAID controller and important safety factors to keep in mind during installation 2 Installing Your 3ware How to install your 3ware RAID controller RAID Controller 3 Installing a Battery How to install and maintain a BBU Backup Unit The following additional documentation is available for your 3ware RAID These cables have multi-lane cable plug connectors on each end (Figure 6). Figure 6. Multi-lane Cable Serial ATA (SFF-8087) SFF-8088 to SFF-8088 Multi-lane cables For use with the 9690SA-8E and 9690SA-4I4E 3ware RAID conIn order to use enclosure support services, such as locating a drive by blinking an LED or notificatiThe 3ware 9690SA RAID controller card should be installed by technically qualified persons. If you are uncomfortable opening a computer system and conforming to standard ESD (electrostatic discharge) practices, you should have a computer tHigh voltages may be found inside computer equipment. Before installing any of the hardware in this package or removing the protective covers of any computer equipment, turn off power switches and disconnect power cords.http://www.szp45.pl/wsg/userfiles/bosch-integra-300-dishwasher-manual.xml Do not reconnect the power cords until the hardware is installed and the system cover is closed. Protecting Equipment and Data Heat Sink Warning. Do not replace the faThe on-board heat sink collects heat, and must have adequate airflow in order to disburse it. It is important that the cables do not obstruct the air flow or prevent proper ventilation of the system. Selecting the Slot in Which to Install the Controller Consider these factors when deciding on the slot iFor details, see “Chapter 3. Installing a Battery Backup UnTurn off power to the computer and disconnect the power cord from the outlet. 2 Make sure you are properly grounded. (For details about safety precautions, see page 8.) 3 Open the computer case according to the manufacturer’s instructions. 4 Locate the PCI Express slot you want to use for the 3ware 9690SA RAID controller. For a discussion of which slot to use, If in doubt about what slots you have, check the documentation for your motherboard. Do NOT use a PCI or PCI-X slot. 8 Check that the 3ware RAID controller’s metal bracket covers the hole in the case and secure the Internal Connectors The 9690SA-8I, 9690SA-8IF, 9690SA-4I, and 9690SA-4I4E controller cards have internal connectors and use the SFF-8087 cable. Insert the SFF-8087 cable plug into the multi-lane connector on the controller. When the cable is inserted correctly, you will feel it click into place. FiguInsert the SFF-8088 cable plug connector into the multi-lane external connector of the controller. When the plug is inserted correctly, you will feel it click into place. Figure 10. Connecting a Multi-lane Cable with an SFF-8088 Connector to the 9690SA-8E Controller Connect the Cables to Backplanes After installing your 3ware RAID controlFinishing Up the RAID Controller Installation After you have installed the controller in the computer and attached appropriate cables to the controller and drives, complete the following steps to complete the hardware installation. Connect Battery.http://www.drupalitalia.org/node/67919 All rights reserved. This publication may be copied or reproduced for reference purposes only. All other purposes require the express written consent of AMCC, 215 Moffett Park Drive, Sunnyvale, CA 94089. This guide tells you how to install it. Using an incorrect cable can result in drives that are not detected. Page 9 Cables SFF-8087-to-SFF-8087 Multi-lane cables Use with an internal connector of the 9690SA-8I, 9690SA-8IF, 9690SA-4I, or 9690SA-4I4E 3ware RAID controller. A list of systems that have been tested is available at Enclosure Requirements In order to attach more than four drives per connector, enclosures with expanders are required. The 3ware 9690SA RAID controller card should be installed by technically qualified persons. Page 13 Safety Information Personal Safety When Installing the 9690SA RAID Controller in Your Computer Warning. High voltages may be found inside computer equipment. Before installing any of the hardware in this package or removing the protective covers of any computer equipment, turn off power switches and disconnect power cords. Do not reconnect the power cords until the hardware is installed and the system cover is closed. Protecting Equipment and Data Heat Sink Warning. Page 14 Chapter 1. Getting Started Installation Considerations Air Flow, Cable Length, and Routing Space Adequate airflow and ventilation are particularly important for 3ware 9690SA RAID controllers. The on-board heat sink collects heat, and must have adequate airflow in order to disburse it. It is important that the cables do not obstruct the air flow or prevent proper ventilation of the system. Page 15 Chapter 2. Installing Your 3ware RAID Controller Tools You Need You will need the following tools during installation: ? ? An ESD grounding strap or mat A Phillips screwdriver Before You Start 3ware 9690SA RAID controllers can be installed in a standard enclosure or in an enclosure with a backplane. 1 Be sure to read “Safety Information” on page 8 in Chapter 1.http://connect-log.com/images/3ware-9650se-2lp-manual.pdf 2 If you have a Battery Backup Unit (BBU), install it before proceeding. For details, see “Chapter 3. Page 16 Chapter 2. Installing Your 3ware RAID Controller Install the Controller in the Computer 1 If the computer is running, shut it down. Turn off power to the computer and disconnect the power cord from the outlet. 2 Make sure you are properly grounded. (For details about safety precautions, see page 8.) 3 Open the computer case according to the manufacturer’s instructions. 4 Locate the PCI Express slot you want to use for the 3ware 9690SA RAID controller. Page 17 Install the Controller in the Computer 7 Press down gently on the edge of the 3ware RAID controller directly above the PCI Express slot until it is fully seated. Figure 8. Inserting Controller Into PCI Express Slot Use a PCI Express slot for the 3ware 9690SA controller. If in doubt about what slots you have, check the documentation for your motherboard. Do NOT use a PCI or PCI-X slot. Page 18 Chapter 2. Installing Your 3ware RAID Controller Attach the Cables to Your Controller The internal and external connectors of the 9690SA RAID controller accept different cable connector plugs. Internal Connectors The 9690SA-8I, 9690SA-8IF, 9690SA-4I, and 9690SA-4I4E controller cards have internal connectors and use the SFF-8087 cable. ? Insert the SFF-8087 cable plug into the multi-lane connector on the controller. When the cable is inserted correctly, you will feel it click into place. Figure 9. Page 19 Connect the Cables to Backplanes External Connectors The 9690SA-8E and 9690SA-4I4E controller cards have external connectors and use the SFF-8088 cable. ? Insert the SFF-8088 cable plug connector into the multi-lane external connector of the controller. When the plug is inserted correctly, you will feel it click into place. Figure 10. Page 20 Chapter 2. Installing Your 3ware RAID Controller Note: If your backplane has individual connections for each drive, or if you do not have a backplane, you can directly connect up to 4 drives per internal connector through use of a breakout cable. Finishing Up the RAID Controller Installation After you have installed the controller in the computer and attached appropriate cables to the controller and drives, complete the following steps to complete the hardware installation. Page 21 Chapter 3. Installing a Battery Backup Unit The Battery Backup Unit (BBU) is an optional add-on consisting of a control module and a battery pack. When used with the 3ware 9690SA RAID controller, the BBU control module is mounted on the RAID controller and the battery pack is installed on a remote battery board. The BBU’s purpose is to supply power to the controller’s memory module in the event of a system power loss. Page 22 Chapter 3. Installing a Battery Backup Unit Before You Start Before installing the BBU, do the following: 1 Decide which expansion slot locations to use for the 3ware RAID controller and the remote battery board. 2 For the remote battery board, consider ventilation and convenience of access for battery replacement. If possible, leave a space for airflow around the remote battery board, as battery life is shortened by excessive heat. Page 23 Installing the Control Module To install the control module Note: The following illustrations show the 9690SA-4I4E. If you have a 9690SA-8E the location of the control module post hole will be different. 1 Remove the screw head from the plastic post on the BBU control module and set it aside (you will reattach it soon.) Figure 11. Page 24 Chapter 3. Installing a Battery Backup Unit 3 Press down gently until the BBU is seated. Figure 13. BBU control module connected to the controller 4 Turn the controller over, insert the plastic screw head that you removed in step 1 into the plastic post, and tighten it gently but firmly. (Do not over-tighten!) 5 If necessary, attach the extension cable to the BBU control module in order to reach the intended location of the remote battery board. 6 Install your 3ware RAID controller. Page 25 Installing the Remote Battery 3 Select the battery location on the remote battery board. The battery can be mounted in 3 different positions, as marked on the board (see Figure 14). Use the position that will make it easiest to connect the battery power cable to the BBU control module on the 3ware RAID controller. Note: You can mount a second battery on the board, if you have another controller. Figure 14. Page 26 Chapter 3. Installing a Battery Backup Unit 4 Mount the battery in the selected location by snapping it in place.Note: The battery will drain if it is plugged into the BBU and there is no power to the unit. Page 28 Chapter 3. Installing a Battery Backup Unit Replacing the Battery The Battery Backup Unit (BBU) will last for many years. The BBU battery has an expected life span of one to two years depending on usage. You can check the current status of the battery, and test it. To obtain a replacement battery module, contact AMCC. Page 29 Replacing the Battery Figure 17. Removing the power cable from the BBU module Press down on the lever-like clip and pull the connector out. 3 Remove the remote battery board from your system. The 3ware 9690SA delivers accelerated SAS performance and the flexibility of internal and external connectivity. AMCC now offers a highly scalable 3ware serial storage product portfolio that includes 2- to 24-ports of SATA connectivity with the 3ware 9650SE and maximized SAS expandability to up to 128 devices per controller with the 3ware 9690SA. Users will also enjoy a unified RAID management interface and software suite which assures a picture perfect configuration experience with every 3ware controller, irrespective of its storage interface. An optional Battery Backup Unit with integrated write journaling and remote battery mounting capability provides added data protection in the event of a power outage. The 3ware 9690SA supports RAID levels 0, 1, 5, 6, 10, 50, and Single Disk. SCSI device driver model to take advantage of SAS or inexpensive Serial ATA drives Command Line Interface (CLI) - scriptable configuration tool. It provides controller, logical unit and driveUser can set the focus to aA logical unit can be a one-tier, two-tier, or three-tierRAID-1 and RAID-5 are examples of two-tier units and RAID-10 and RAID-50 are examples of three-tier unitsEach port can be attached to a single disk drive. On a controller such as the 9650SE with a multilane serial port connector, oneOn the 9690SA and 9750 controllers, connections The 9690SA controller A vport indicates the ID of a drive, whetherFor dual-ported drives, althoughThis is because the drive is Therefore, unless otherwise Note: The primary command syntaxThe following is a summary of the Messages, and descriptions and examples are presented for each object message For these, the command For the former please see Features sections. Messages are commands It may be a read operation such as for theAttributes are either Boolean Attributes or Named Attributes. Value of a BooleanValue of named attributes areNote that theMIGRATING, MIGRATE-PAUSED, RECOVERY, INOPERABLE, and UNKNOWN. As example: For more information This command is active inRecall that messages (orThe concept is similar to being in a particular location in a file system andThe hostname is the name of With current releases, the Rescanning the controller will clear the error status Thus, unlike the older display, the Moreover, if there are no Summary would show an empty summary consisting of only the header. See other show sub-commands below. Release 9.5.1 or earlier: Release 9.5.2 or later: In the unit summary of the For example: An invalid attribute will terminate the loop. Possible attributes are: achip, allunitstatus, autocarve (9550SX and higher), Connections If the ondegrade If the ondegrade policy is off, a unit cache policy If the policy is on, allEach volume can be treated as an individual disk with its own file system. The default carvesize is 2 TB. For 32-bit OS users, it is recommended to keep the policy on unless users Display will also show the default Running Average, and ext for Extended Drive Statistics. More detailed See Shell Object Messages for more on Not. Optimal definition. By default the host Specifying One or more ports can be specified. Multiple. For example. The followingAt the most bottom layer. N number of disks per group are used to form the RAID-5 layer. These. RAID-5 arrays are then integrated into a RAID-0. This attribute allowsValid valuesHowever given 12 disks, specifying 3 will create four RAID-5 under the RAID-0 By default CLI will inform the OS. One application of this feature is to avoid Enabling the write cache increases performance at No caching is recommended when no BBU or UPS If a BBU or. UPS is not installed, to avoid possibility of data loss in the event of suddenThe rdcachebasic For more details on this. For the 9650SE, For other 9000 series controllers Keep in mind however, that That is, for For the spare unit, drive queueing is not meaningful and the qpolicy cannot The following table illustrates the supported No space is allowed within the string. If user likesUser can change the name of the unit This is a feature for 9000 or above series ofThe value(s) should beZero (0) is an invalid LUN Note that thereRapid RAID Recovery can speed up the rebuild This feature allows for expedited boot-up time in the event of an unclean Setting it to rebuild applies the If the policy is set to disable, then Also, once disabled, that setting could not be In addition. Rapid RAID Recovery is not supported over migration. Any newly found unit(s) or drive(s) will be listed.Default is to inform If a failure (suchThis command allows theThis command can then expediteDCB's in-transaction flag as we are going down. Subsequently a recommendation is given to the user followed by a prompt to continue. Once the user decides to proceed, the image will be downloaded to the controller. However, a reboot is required for the new image to take effect. Before you update the firmware,With it the warning message is suppressed, as Compatibility checks are not bypassed. If the These events are kept in a finite queue inside. These events reflect messages of varying severity levels. The levels range The default Likewise, the older the event The order of the messages could be With this the most recent AEN message Note that some characters might not be printable or rendered correctly (humanIt reports a list of phys with related information The 'Device Type' column indicates whether There are three 'Link Speed' The current link speed for phy1 is 3.0 Gpbs, and the link control setting isMoreover, the only changeableTo change the link speed, see the. To see information for an individualFor each activity, up to 7 tasks can be registered, Background tasks have Rebuilds can be started manually Scheduled rebuilds will take This command shows the current rebuild task rate of the The advanced Verify Task Schedule provides RAID-1 involves checking that both drives contain the exact data. On RAID-5 and. RAID-6, the parity information is used to verify data integrity. RAID-10 and 50 On the 9000 series, For the 9650SE and newer controllers, if the basic Verify Task Schedule is This command shows the current verify task rate of the For each activity, up to 7 tasks can be registered, known Background tasks have attributes of The SMART selftest instructs the controller to check certain SMART supported thresholdsThis command will fail if no (empty) slot is available. In that case,In that case, Simply specify a weekly day and time and make sure For more information. Features section of this document. This command will fail if no (empty) slot Otherwise, no firmware initiated or manually started rebuild tasks would run. Otherwise, no firmware initiated or manually started verify tasks would run. When enabled, only registered or scheduled tasks Setting this value to Conversely setting this value to 1 implies The Adaptive The Low Latency setting has been described above. Accordingly, the converse is also true. When enabled, only registered or scheduled Setting this value to 5 Conversely setting this value to 1 implies For more information, see the command Release 9.5.2 or later. Setting verify to advanced enables the Verify Tasks Schedule, which Setting verify toFor more information, see This command allows you to offset this condition by setting the rebuild mode to low The Adaptive The Low Latency setting has been described above. When enabled, the selftest task will beIf the policyFor example, given a spin up policy of 2, the controller will spin up two disksThe amount of timeThese statistics can be helpful when When the Auto-Carving policy is ON, any unit larger than the carvesize This feature is useful for For a 5 TB array, two 2 TB volumes This feature worksAfter the drives are inserted or re-inserted to Please note that the command takes longer to complete for ports that do not have This command applies to This command applies to If the Auto-Carving policy Verifying, Initializing, or Migrating). As a result, an added For example: The process of either. Verifing, Initializing, or Migrating is at 70 and it is a paused process. Currently, The unit is also in the paused An invalid attribute will terminate the loop. Possible attributes are: initializestatus, name (9000 series), qpolicy (9550SX If the queue Some drives For example, when a spare becomes a true unit in migration, it would adopt. Thus, this commmand does not show the If set to ON, the LEDs of the drive slots associated with the specified unit wouldThe state of the read cache could be either basic, intelligent, or. For more informationThis policy can be all, rebuild, or disable. For more information Exporting a unit will instructAs such the unit can later be importedDefault is to inform the OS. The quiet option is for non-interactive mode. Units that are currently in use or mountedDeleting a unit not only remove the Ports (or disks) associated with this In another words, onceDefault is to inform This is a destructive command and should be Units that are currently in use or mountedDuring rebuild, bad sectors on the source disk will cause the rebuild to fail. You can allow for the operation to continue via ignoreECC. Rebuild process isThis feature is intended for model 7000 and 8000Model 9000 has an on-board scheduler where rebuild operations can be scheduled If the allocated schedule windows isThis featureFor earlier controller models, This improves read access times for applications such as a database that Read cache may be disabled without This new feature includes a typical read ahead caching method, which is used For example, the By loading a larger set of data This can be helpful with applications that are Performance benefits of read-ahead In addition, Cache setting. If set to ON, Setting overwriteECC to on means ignoreECC. This feature only applies toNo space is allowed within the string. If user likes to use some special characters It is user's responsibility to give unique This feature only applies to 9000 models. If the queue policy isSome drivesFor example, when a Rapid RAID Recovery can speed up the rebuild process, and it can speed up This feature allows for Setting this The following description about the settingsWhen user sets storsave to protect, it means: When user sets the storsave BBU is installed and enabled; Otherwise, will be flushed to disk only, and For example, a valid number The destination unit must use all source. Unspecified parameters are assigned default values (stripe size of 64K, write If the source unit is of type. RAID-1 and the destination unit is of type single, the disk-specifier of the In this case, A four-drive RAID-5 unit can migrate to a four-drive. RAID-0, but a four-drive RAID-0 unit cannot migrate to a four-drive RAID-5, withoutOne or more ports. For exampleRecall that a RAID-50 is a multi-tier RAID-5 layer. These RAID-5 arrays are then integrated into a RAID-0. This option Valid values are 3, The following table By default CLI will inform the OS. One application By default the cache is enabled. Unless there is a BBU or UPS installed, to You can continueOnce the migration is finished, a reboot For secondary storage, depending For instructions, Making any physical changes to the Following those areAfter which example outputs showing theIn this example, In addition, the status of the newly specified disk Single to a RAID-1, initiated by the following commands: Western Digital disk with status OK and is a part of unit u5. This is a list of the possible One or many attributes can be requested. Invalid Possible attributes are: status, model,Its intended use is not for determining theNote the difference The LED of the drive slot associated with the specified port would blink if the The capacity in GB is computed basedTherefore, a requestThe 'type' in the command specifies which The options are either: inst for. Instantaneous, ra for Running Average, lct for Long Command Times,More detailed information regarding these statistics and the Drive. Performance Monitor is available in the Features section under 'Drive. Performance Monitor'. You can import (or re-introduce) the portUse noscan to bypass informing the OS of this The quiet option is for the non-interactive Drives, which are part of a redundantNon-redundant drives, If set to ON, the LED of the drive slot associated with the specified port would The optional 'type' in the command specifies which set of statistics data would be Command Times,and ext for Extended Drive Statistics. More detailed information If no type isMonitor' in the 'Features' section. This command presents a summary report on the The 'Device' column There are three 'Link Speed' columns: 'Supported' Note that the Supported and Enabled values are not changeable. The Control The default This command sets the link speed The unit of link speed is in gigabits per second (Gbps). The default is auto. The commands in this Both voltage and temperature BBU board. One or many attributes can be requested. Invalid attribute willPossible values are: It may take up to 24 hours to complete. During the test, the BBU is not capable of backup operation and the writeIf the test is completed withIf a Fault, Failed or an Error occurs during the test, the write cache remains at theThe charging is started automatically During the charging, the BBU is not capable Once charging is completedAt this state, the BBU is not capable of backup We recommend you to replace theAt this state, the BBU is not capable of backupWe recommend you to replace theAt this state, the BBU is not capable of backupWe recommend you to replace theThe status can be OK. HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are in warning range. TOO-HIGHThe status can be. OK, HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are in warning range. TOO-HIGH and TOO-LOW are out of the operating range and need to be concerned. The test may take up to 24 hoursThe performance of all units under theOnce the test Event Notifications) about the status of the test operation. The controller will utilize BBU The controller ignores the In another words, despiteThe enclosure element object messages are The subsectionsFor systems with the 9650SE controller or CCU enclosure, simply drop the pre-pended One or many An invalid attribute will terminate the loop. Possible For the new syntax, this command is not very useful, since the controller that the This command Status column lists the status of each slot, the (V)Port column shows the Status column lists the status of each fan, the State column shows if the fan If the image is valid a subsequent message will indicate It identifies the target SEP expander in the With it the warning message, version check, and The image will initiate the download immediately. Only expander models in this list are supported. Please refer to. Click on the Data and Interoperability tab, and then click on the 3ware. Interoperability Information link to check if your expander is supported. For example, be sure to unmount any mounted Before you update the firmware, it isIn the example, it If a slot has been inserted with a drive and no If the slot is empty the The port that is correlated to the slot is If no device is found in that slot, this column The next column shows whether the specified slot has Likewise, for Slot Identify. If supported, setting it to ON will blink the LED of the For example: Likewise, for If supported, setting it to ON will blink The possible status values are OK, OVER-WARNING, OVER-FAIL, UNDER-WARNING. UNDER-FAIL, where OVER denotes over-temperature and UNDER denotes under-temperature. If supported, setting it to. ON will blink the LED associated with the specified temperature element. The possible status values are OK, FAIL, NOT-INSTALLED, and OFF. The voltage In either case. OVER- means over the set threshold of the voltage or current.