Error message

Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home1/dezafrac/public_html/ninethreefox/includes/common.inc).

7

3ware 9690 manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:3ware 9690 manual.pdf
Size: 3527 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 14 May 2019, 12:34 PM
Rating: 4.6/5 from 594 votes.

Status: AVAILABLE

Last checked: 7 Minutes ago!

In order to read or download 3ware 9690 manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

3ware 9690 manualUsing an incorrect cable can result in drives that are not detected. These cables have multi-lane cable plug connectors on each end (Figure 6). Figure 6. If you are uncomfortable opening a computer system and conforming to standard ESD (electrostatic discharge) practices, you should have a computer technician perform the installation. Replacing the heat sink will alter thermal characteristics and cooling requirements and may cause the controller to fail. Replacing the factory-installed heat sink will void the warranty. The on-board heat sink collects heat, and must have adequate airflow in order to disburse it. It is important that the cables do not obstruct the air flow or prevent proper ventilation of the system. If your enclosure is low-profile, unscrew the full height bracket from the 3ware 9690SA RAID controller and replace it with the included low-profile bracket, using the same screws. If appropriate, set the PM2 (power management) jumper on the disk drives, to enable staggered spinup. Save this screw; it will be used to secure the 3ware 9690SA RAID controller after you have seated it in the slot. Position the card in the PCI Express slot so that the contacts will mate with the grooves in the slot, and all pins make proper contact with the PCI Express slot pins when pushed into place. Check that the 3ware RAID controller’s metal bracket covers the hole in the case and secure the bracket with the screw that was used to secure the filler bracket in step 5. Insert the SFF-8088 cable plug connector into the multi-lane external connector of the controller. When the plug is inserted correctly, you will feel it click into place. The user guide is included on the 3ware CD that came with your controller.When used with the 3ware 9690SA RAID controller, the BBU control module is mounted on the RAID controller and the battery pack is installed on a remote battery board. If you have a 9690SA-8E the location of the control module post hole will be different.http://banzayclub.ru/userfiles/bosch-instantaneous-gas-hot-water-manual.xml

    Tags:
  • 3ware 9690sa-8i manual, 3ware 9690 manual, 3ware 9690 manual download, 3ware 9690 manual pdf, 3ware 9690 manuals, 3ware 9690 manual instructions.

Remove the screw head from the plastic post on the BBU control module and set it aside (you will reattach it soon.) Figure 11. The battery can be mounted in 3 different positions, as marked on the board (see Figure 14). Use the position that will make it easiest to connect the battery power cable to the BBU control module on the 3ware RAID controller. Press down on the top of the battery module to free the clip on the bottom of the module. While pressing down on the top of the battery module, lift out the bottom of the battery module slightly. AMCC also offers toll-free 1 (800) 840-6055 or 1 (858) 535- 6517 direct phone support during normal business hours. This publication may be copied or reproduced for reference purposes only. All other purposes require the express written consent of AMCC, 215 Moffett Park Drive, Sunnyvale, CA 94089.Chapter Description 1 Getting Started Overview of the 3ware RAID controller and important safety factors to keep in mind during installation 2 Installing Your 3ware How to install your 3ware RAID controller RAID Controller 3 Installing a Battery How to install and maintain a BBU Backup Unit The following additional documentation is available for your 3ware RAID These cables have multi-lane cable plug connectors on each end (Figure 6). Figure 6. Multi-lane Cable Serial ATA (SFF-8087) SFF-8088 to SFF-8088 Multi-lane cables For use with the 9690SA-8E and 9690SA-4I4E 3ware RAID conIn order to use enclosure support services, such as locating a drive by blinking an LED or notificatiThe 3ware 9690SA RAID controller card should be installed by technically qualified persons. If you are uncomfortable opening a computer system and conforming to standard ESD (electrostatic discharge) practices, you should have a computer tHigh voltages may be found inside computer equipment. Before installing any of the hardware in this package or removing the protective covers of any computer equipment, turn off power switches and disconnect power cords.http://h04ydivan.ru/userfiles/file/bosch-instantaneous-gas-hot-water-manual.xml Do not reconnect the power cords until the hardware is installed and the system cover is closed. Protecting Equipment and Data Heat Sink Warning. Do not replace the faThe on-board heat sink collects heat, and must have adequate airflow in order to disburse it. It is important that the cables do not obstruct the air flow or prevent proper ventilation of the system. Selecting the Slot in Which to Install the Controller Consider these factors when deciding on the slot iFor details, see “Chapter 3. Installing a Battery Backup UnTurn off power to the computer and disconnect the power cord from the outlet. 2 Make sure you are properly grounded. (For details about safety precautions, see page 8.) 3 Open the computer case according to the manufacturer’s instructions. 4 Locate the PCI Express slot you want to use for the 3ware 9690SA RAID controller. For a discussion of which slot to use, If in doubt about what slots you have, check the documentation for your motherboard. Do NOT use a PCI or PCI-X slot. 8 Check that the 3ware RAID controller’s metal bracket covers the hole in the case and secure the Internal Connectors The 9690SA-8I, 9690SA-8IF, 9690SA-4I, and 9690SA-4I4E controller cards have internal connectors and use the SFF-8087 cable. Insert the SFF-8087 cable plug into the multi-lane connector on the controller. When the cable is inserted correctly, you will feel it click into place. FiguInsert the SFF-8088 cable plug connector into the multi-lane external connector of the controller. When the plug is inserted correctly, you will feel it click into place. Figure 10. Connecting a Multi-lane Cable with an SFF-8088 Connector to the 9690SA-8E Controller Connect the Cables to Backplanes After installing your 3ware RAID controlFinishing Up the RAID Controller Installation After you have installed the controller in the computer and attached appropriate cables to the controller and drives, complete the following steps to complete the hardware installation. Connect Battery.http://www.drupalitalia.org/node/67913 It provides controller, logical unit and driveUser can set the focus to aA logical unit can be a one-tier, two-tier, or three-tierRAID-1 and RAID-5 are examples of two-tier units and RAID-10 and RAID-50 are examples of three-tier unitsEach port can be attached to a single disk drive. On a controller such as the 9650SE with a multilane serial port connector, oneOn the 9690SA and 9750 controllers, connections The 9690SA controller A vport indicates the ID of a drive, whetherFor dual-ported drives, althoughThis is because the drive is Therefore, unless otherwise Note: The primary command syntaxThe following is a summary of the Messages, and descriptions and examples are presented for each object message For these, the command For the former please see Features sections. Messages are commands It may be a read operation such as for theAttributes are either Boolean Attributes or Named Attributes. Value of a BooleanValue of named attributes areNote that theMIGRATING, MIGRATE-PAUSED, RECOVERY, INOPERABLE, and UNKNOWN. As example: For more information This command is active inRecall that messages (orThe concept is similar to being in a particular location in a file system andThe hostname is the name of With current releases, the Rescanning the controller will clear the error status Thus, unlike the older display, the Moreover, if there are no Summary would show an empty summary consisting of only the header. See other show sub-commands below. Release 9.5.1 or earlier: Release 9.5.2 or later: In the unit summary of the For example: An invalid attribute will terminate the loop. Possible attributes are: achip, allunitstatus, autocarve (9550SX and higher), Connections If the ondegrade If the ondegrade policy is off, a unit cache policy If the policy is on, allEach volume can be treated as an individual disk with its own file system. The default carvesize is 2 TB.http://complexitycafe.com/images/3ware-9650se-user-manual.pdf For 32-bit OS users, it is recommended to keep the policy on unless users Display will also show the default Running Average, and ext for Extended Drive Statistics. More detailed See Shell Object Messages for more on Not. Optimal definition. By default the host Specifying One or more ports can be specified. Multiple. For example. The followingAt the most bottom layer. N number of disks per group are used to form the RAID-5 layer. These. RAID-5 arrays are then integrated into a RAID-0. This attribute allowsValid valuesHowever given 12 disks, specifying 3 will create four RAID-5 under the RAID-0 By default CLI will inform the OS. One application of this feature is to avoid Enabling the write cache increases performance at No caching is recommended when no BBU or UPS If a BBU or. UPS is not installed, to avoid possibility of data loss in the event of suddenThe rdcachebasic For more details on this. For the 9650SE, For other 9000 series controllers Keep in mind however, that That is, for For the spare unit, drive queueing is not meaningful and the qpolicy cannot The following table illustrates the supported No space is allowed within the string. If user likesUser can change the name of the unit This is a feature for 9000 or above series ofThe value(s) should beZero (0) is an invalid LUN Note that thereRapid RAID Recovery can speed up the rebuild This feature allows for expedited boot-up time in the event of an unclean Setting it to rebuild applies the If the policy is set to disable, then Also, once disabled, that setting could not be In addition. Rapid RAID Recovery is not supported over migration. Any newly found unit(s) or drive(s) will be listed.Default is to inform If a failure (suchThis command allows theThis command can then expediteDCB's in-transaction flag as we are going down. Subsequently a recommendation is given to the user followed by a prompt to continue. Once the user decides to proceed, the image will be downloaded to the controller. However, a reboot is required for the new image to take effect. Before you update the firmware,With it the warning message is suppressed, as Compatibility checks are not bypassed. If the These events are kept in a finite queue inside. These events reflect messages of varying severity levels. The levels range The default Likewise, the older the event The order of the messages could be With this the most recent AEN message Note that some characters might not be printable or rendered correctly (humanIt reports a list of phys with related information The 'Device Type' column indicates whether There are three 'Link Speed' The current link speed for phy1 is 3.0 Gpbs, and the link control setting isMoreover, the only changeableTo change the link speed, see the. To see information for an individualFor each activity, up to 7 tasks can be registered, Background tasks have Rebuilds can be started manually Scheduled rebuilds will take This command shows the current rebuild task rate of the The advanced Verify Task Schedule provides RAID-1 involves checking that both drives contain the exact data. On RAID-5 and. RAID-6, the parity information is used to verify data integrity. RAID-10 and 50 On the 9000 series, For the 9650SE and newer controllers, if the basic Verify Task Schedule is This command shows the current verify task rate of the For each activity, up to 7 tasks can be registered, known Background tasks have attributes of The SMART selftest instructs the controller to check certain SMART supported thresholdsThis command will fail if no (empty) slot is available. In that case,In that case, Simply specify a weekly day and time and make sure For more information. Features section of this document. This command will fail if no (empty) slot Otherwise, no firmware initiated or manually started rebuild tasks would run. Otherwise, no firmware initiated or manually started verify tasks would run. When enabled, only registered or scheduled tasks Setting this value to Conversely setting this value to 1 implies The Adaptive The Low Latency setting has been described above. Accordingly, the converse is also true. When enabled, only registered or scheduled Setting this value to 5 Conversely setting this value to 1 implies For more information, see the command Release 9.5.2 or later. Setting verify to advanced enables the Verify Tasks Schedule, which Setting verify toFor more information, see This command allows you to offset this condition by setting the rebuild mode to low The Adaptive The Low Latency setting has been described above. When enabled, the selftest task will beIf the policyFor example, given a spin up policy of 2, the controller will spin up two disksThe amount of timeThese statistics can be helpful when When the Auto-Carving policy is ON, any unit larger than the carvesize This feature is useful for For a 5 TB array, two 2 TB volumes This feature worksAfter the drives are inserted or re-inserted to Please note that the command takes longer to complete for ports that do not have This command applies to This command applies to If the Auto-Carving policy Verifying, Initializing, or Migrating). As a result, an added For example: The process of either. Verifing, Initializing, or Migrating is at 70 and it is a paused process. Currently, The unit is also in the paused An invalid attribute will terminate the loop. Possible attributes are: initializestatus, name (9000 series), qpolicy (9550SX If the queue Some drives For example, when a spare becomes a true unit in migration, it would adopt. Thus, this commmand does not show the If set to ON, the LEDs of the drive slots associated with the specified unit wouldThe state of the read cache could be either basic, intelligent, or. For more informationThis policy can be all, rebuild, or disable. For more information Exporting a unit will instructAs such the unit can later be importedDefault is to inform the OS. The quiet option is for non-interactive mode. Units that are currently in use or mountedDeleting a unit not only remove the Ports (or disks) associated with this In another words, onceDefault is to inform This is a destructive command and should be Units that are currently in use or mountedDuring rebuild, bad sectors on the source disk will cause the rebuild to fail. You can allow for the operation to continue via ignoreECC. Rebuild process isThis feature is intended for model 7000 and 8000Model 9000 has an on-board scheduler where rebuild operations can be scheduled If the allocated schedule windows isThis featureFor earlier controller models, This improves read access times for applications such as a database that Read cache may be disabled without This new feature includes a typical read ahead caching method, which is used For example, the By loading a larger set of data This can be helpful with applications that are Performance benefits of read-ahead In addition, Cache setting. If set to ON, Setting overwriteECC to on means ignoreECC. This feature only applies toNo space is allowed within the string. If user likes to use some special characters It is user's responsibility to give unique This feature only applies to 9000 models. If the queue policy isSome drivesFor example, when a Rapid RAID Recovery can speed up the rebuild process, and it can speed up This feature allows for Setting this The following description about the settingsWhen user sets storsave to protect, it means: When user sets the storsave BBU is installed and enabled; Otherwise, will be flushed to disk only, and For example, a valid number The destination unit must use all source. Unspecified parameters are assigned default values (stripe size of 64K, write If the source unit is of type. RAID-1 and the destination unit is of type single, the disk-specifier of the In this case, A four-drive RAID-5 unit can migrate to a four-drive. RAID-0, but a four-drive RAID-0 unit cannot migrate to a four-drive RAID-5, withoutOne or more ports. For exampleRecall that a RAID-50 is a multi-tier RAID-5 layer. These RAID-5 arrays are then integrated into a RAID-0. This option Valid values are 3, The following table By default CLI will inform the OS. One application By default the cache is enabled. Unless there is a BBU or UPS installed, to You can continueOnce the migration is finished, a reboot For secondary storage, depending For instructions, Making any physical changes to the Following those areAfter which example outputs showing theIn this example, In addition, the status of the newly specified disk Single to a RAID-1, initiated by the following commands: Western Digital disk with status OK and is a part of unit u5. This is a list of the possible One or many attributes can be requested. Invalid Possible attributes are: status, model,Its intended use is not for determining theNote the difference The LED of the drive slot associated with the specified port would blink if the The capacity in GB is computed basedTherefore, a requestThe 'type' in the command specifies which The options are either: inst for. Instantaneous, ra for Running Average, lct for Long Command Times,More detailed information regarding these statistics and the Drive. Performance Monitor is available in the Features section under 'Drive. Performance Monitor'. You can import (or re-introduce) the portUse noscan to bypass informing the OS of this The quiet option is for the non-interactive Drives, which are part of a redundantNon-redundant drives, If set to ON, the LED of the drive slot associated with the specified port would The optional 'type' in the command specifies which set of statistics data would be Command Times,and ext for Extended Drive Statistics. More detailed information If no type isMonitor' in the 'Features' section. This command presents a summary report on the The 'Device' column There are three 'Link Speed' columns: 'Supported' Note that the Supported and Enabled values are not changeable. The Control The default This command sets the link speed The unit of link speed is in gigabits per second (Gbps). The default is auto. The commands in this Both voltage and temperature BBU board. One or many attributes can be requested. Invalid attribute willPossible values are: It may take up to 24 hours to complete. During the test, the BBU is not capable of backup operation and the writeIf the test is completed withIf a Fault, Failed or an Error occurs during the test, the write cache remains at theThe charging is started automatically During the charging, the BBU is not capable Once charging is completedAt this state, the BBU is not capable of backup We recommend you to replace theAt this state, the BBU is not capable of backupWe recommend you to replace theAt this state, the BBU is not capable of backupWe recommend you to replace theThe status can be OK. HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are in warning range. TOO-HIGHThe status can be. OK, HIGH, LOW, TOO-HIGH, and TOO-LOW. The HIGH and LOW are in warning range. TOO-HIGH and TOO-LOW are out of the operating range and need to be concerned. The test may take up to 24 hoursThe performance of all units under theOnce the test Event Notifications) about the status of the test operation. The controller will utilize BBU The controller ignores the In another words, despiteThe enclosure element object messages are The subsectionsFor systems with the 9650SE controller or CCU enclosure, simply drop the pre-pended One or many An invalid attribute will terminate the loop. Possible For the new syntax, this command is not very useful, since the controller that the This command Status column lists the status of each slot, the (V)Port column shows the Status column lists the status of each fan, the State column shows if the fan If the image is valid a subsequent message will indicate It identifies the target SEP expander in the With it the warning message, version check, and The image will initiate the download immediately. Only expander models in this list are supported. Please refer to. Click on the Data and Interoperability tab, and then click on the 3ware. Interoperability Information link to check if your expander is supported. For example, be sure to unmount any mounted Before you update the firmware, it isIn the example, it If a slot has been inserted with a drive and no If the slot is empty the The port that is correlated to the slot is If no device is found in that slot, this column The next column shows whether the specified slot has Likewise, for Slot Identify. If supported, setting it to ON will blink the LED of the For example: Likewise, for If supported, setting it to ON will blink The possible status values are OK, OVER-WARNING, OVER-FAIL, UNDER-WARNING. UNDER-FAIL, where OVER denotes over-temperature and UNDER denotes under-temperature. If supported, setting it to. ON will blink the LED associated with the specified temperature element. The possible status values are OK, FAIL, NOT-INSTALLED, and OFF. The voltage In either case. OVER- means over the set threshold of the voltage or current. Likewise, for If supported, setting it to ON The possible The status values The possible It provides It also gives you In the case where a known In this case, the alarm This is because the unmute In effect, for The alarm is turned on by firmware when Setting the alarm To silence the alarm you may set the state of the The difference between using Online help providesFor Read Cache Basic use rdcachebasic.For Read Cache Basic use rdcachebasic.Help does not extend to theFor Read Cache Basic use rdcachebasic.Typical output looks like: It provides reports on Controllers, Units and Drives. See the Shell Object Messages section for more on show. See the Shell Object Messages section for more. See the Shell Object Messages section for more. See the Shell Object Messages section for more. See the Shell Object Messages section for more. Note where ON is indicated, OFF Properties, click on the Advanced tab. Then click on the Environment Windows and read by CLI upon system startup, after which CLI will stop logging To display it in. Windows Explorer, enter c:\ProgramData in the location field at the top To make the folder permanently visible, select Also, some of these features The purpose of this section is to provide an encapsulated view of selectedSyntax section of this document. While some commands contain similar or Those that do not is likelyIn any case, the explanations are The running The long command Finally, the extendedAt this time, the only setting that the user can change is 'enable' or 'disable'The port-based 'show' commands provide The port-based 'set' command clears the While these commands require the specification of The command Following the If the setting If the setting is OFF, the same table layout is Thus, when the drive performance monitor is OFF, the data For example: For example: For example: For example: For example: In the display Note that for For example: The default thus effectively clears Also, some statistics. Attempting to clear these will return an error. For example: For example: To clear the For example: Effectively this feature RAID-5, RAID-6, RAID-10 and RAID-50. This feature is not supported over migration. This configuration may be Rapid RAID Recovery policy will apply to rebuild, initialize, and verify tasks at Please note that once this attribute is set for the unit, the policy setting As a result, if you issue the To turn off the message and promptCreating a RAID-5 As a result an extra query hasIf the user confirms, The first volumeThis featureRAID-10, RAID-5, RAID-50, RAID-6 and Single. If autocarve has been set to ON, then the sizes of For example, if the carvesize Note the while the last specified carved size With v0 onlyWith vol, up to four LUNThe input of size is an integer in The maximum Selftest in the RAID system. It performs data integraty checks on an array For a RAID-1 array, for example, the verification The Verify functionParticularly the scheduled time windows of A scheduled time window, The Schedule contains a default set of verifyThe sections below describe this in more detail. The Autoverify setting letsSchedule) when it is set to ON. If a verify process has started and the verify Again, firmware makes its decision autonomously The following is the set of commands associated with this: Syntax section of this document. Thus it is important to note their interactions. The following table summarizes the setting parameters and corresponding system Verify is supported on 9650SE and 9690SA controllers. In such systems, to set Please note that this systemWe will delete timeslot-3. Will be initialized first before verified. It describes the Advanced Verify with respect to when scheduled verify tasks may execute, the. Basic Verify feature was introduced to provide a more simplistic verify But supplies the Generally, this is supported in the 9650SE, 9690SA and 9750 It describes the On success, 0 is returned. On failure 1 is returned. For example, firmware. PCB, PCHIP and similar information have been removed from the info summary report, The intent isIf such action is needed, use the rebuild scheduling to handle it. The BTA offers structured, e-learning, face-to-face, labs and training, delivered by world-class trainers, tailored to the knowledge-base of the attendees from beginner up to expert. The 3ware 9690SA delivers accelerated SAS performance and the flexibility of internal and external connectivity.Remote access is also available. This publicatio n may be copied or reprodu ced for reference purposes only. All other purposes require the express written consent of AMCC, 215 Moff ett Park Drive, Sunnyvale, CA 94089. The 3w are logo, 3BM, Multi-Lane, StorSav e, StorSwitch, S treamFusion, and R5 Fusion are all trademarks of AMCC. PowerP C and the PowerPC logo are trademarks of International Bu siness Machines Corporation. All other trademarks herein are property of their respective owners. Disc laimer While every attempt is made to make this document as accurate as possible, AMCC assumes no responsibility for errors or omissions in this document, nor does AMCC make any commit ment to update the information contained herein. The following additional documenta tion is available for your 3ware RAID controller on the CD that came with your controller. Online help is also available when you are using 3DM 2 (3ware Disk Manager).One of the following 3ware 9690 SA RAID controller cards: ? 9690SA-8E (two extern al 4x wide ports) ? 9690SA-8I (two internal 4x wide ports) ? 9690SA-4I4E (one internal 4x wide port and one external 4x wide port).Using an incorrect cable can result in drives that are no t det ected. The appropriate cables are included with you r controller. If you must replace a cable, see the list of available cables and associa ted p art numbers at. One external Multi-lane One internal Multi-lane connect or Heat Sinks BBU connector and hole I 2 C connector Multi-lane SA T A breakout ca ble (SFF-8087) for direct connection to SA T A drives from internal connectors.W indows XP, W indows Server 2003 (32-bit and 64-bit x86), W indows V ista (32-bit and 64-bit x86). Red Hat Linux, 32-bit and 64-bit x86. SuSE Linux, 32-bit and 64-bit x86. Fedora Core, 32-bit and 64-bit x86.Adequate power supply for driv es ? 3DM 2 (3ware Disk Manager), a browser-based application used to configure and maintain RAID units, requires one of the following browsers. Internet Explorer 5.5 and later ? Mozilla Firefox 1.2 and later ? Netscape 7 and later. Konquerer 3.5.1 and later In addition. JavaScript must be enabled. Cookies must be enabled For best viewing, screen resolution shoul d be 1024 x 768 or g reater, with 16-bit color or greater. Saf ety Infor mation T o reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this info rmation and observe all warnings and precautions in this guide before installing or maintaining your computer. The 3ware 9690SA RAID controller card should be installed by technically qualified persons. If you are uncomfortable opening a computer system and conforming to standard ESD (electrostatic discharge) practices, you should have a c omputer technician perform the installation. Site Selection The product is designed to operate as a componen t to a computer system. The environment that is pr ovided for the system must be. Clean, dry, and fre e of airborne particles (other than normal room dust). During an electrical storm, we recommend discon necting all phone, network, and power cables. ? Provided with a properly grounded wall outlet. ? Provided a product main power disconnect or sufficient space to access the power supply cord(s), because they serve as the product's main power disconne ct. P er sonal Safety W hen Installing the 9690SA RAID Controller in Y our Computer Protecting Equipment and Data W arning. High voltages may be found inside computer equipment. Before installing any of the hardware in this package or removing the protective covers of any computer equi pment, turn off power switches and disconnect power cords.