Error message

Deprecated function: implode(): Passing glue string after array is deprecated. Swap the parameters in drupal_get_feeds() (line 394 of /home1/dezafrac/public_html/ninethreefox/includes/common.inc).

7

3mtm static sensor 718 instruction manual

LINK 1 ENTER SITE >>> Download PDF
LINK 2 ENTER SITE >>> Download PDF

File Name:3mtm static sensor 718 instruction manual.pdf
Size: 1896 KB
Type: PDF, ePub, eBook

Category: Book
Uploaded: 11 May 2019, 22:11 PM
Rating: 4.6/5 from 666 votes.

Status: AVAILABLE

Last checked: 4 Minutes ago!

In order to read or download 3mtm static sensor 718 instruction manual ebook, you need to create a FREE account.

Download Now!

eBook includes PDF, ePub and Kindle version

✔ Register a free 1 month Trial Account.

✔ Download as many books as you like (Personal use)

✔ Cancel the membership at any time if not satisfied.

✔ Join Over 80000 Happy Readers

3mtm static sensor 718 instruction manualDo not disassemble the products for any reason.It can beused to locate ESD trouble-areas, and is a valuable tool for the ESD-control engineer. Used in conjunction with. At this time, the Static Sensor 718 will not produce accurate results and the battery should be replaced. Once the battery is depleted to approximately 6.5 volts, the instrument will show BAT in the display. At this time, the Static Sensor 718 will not produce accurate results and the battery should be replaced. Please contact your 3M representative for additional. The mark indicates the requirement NOT to dispose the equipment as unsorted municipal waste, but use the return and collection systems according to local law. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. It can beused to locate esd trouble-areas, and is a valuable tool for the esd-control engineer. Once the battery is depleted to approximately 6.5 volts, the instrument will show bat in the display. Improper use or rough treatment can damage the unit, and render it incapable of providing accurate measurements.2.2.4 replace the cover. 2.3 the static sensor 718 has a low battery indicator. Once the battery is depleted to approxima. Page 7: Zero Adjustment: The 3M 6 and return to floating measurement, momentarily press the hold switch once again. This output can be used to feed a continuous signal into a data storage device for continuous monitoring of measured voltages. If illuminated, replace the battery in the charger. If the unit continues to supply an incorrect volta. The user, usually according to internal quality proce.Charge plate assembly 718a 1 ea. The mark indicates the requirement not to dispose the equipment as unsorted munic.http://www.klcconsulting.eu/klc/4-speed-manual-transmission-with-overdrive.xml

    Tags:
  • 3mtm static sensor 718 instruction manual, 3mtm static sensor 718 instruction manual pdf, 3mtm static sensor 718 instruction manual download, 3mtm static sensor 718 instruction manual instructions, 3mtm static sensor 718 instruction manual free.

Page 14 Important notice all statements, technical information, and recommendations related to 3m’s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended. Usage of Page 1. Hand-held static sensor locates and meas- ures static voltages, tests air ionizers. New from 3M, the 718 Static Sensor can help companies competing in the Static Sensor. View online or download 3m 718 User Manual.Catalogs SK Series High-precision Electrostatic Sensor Catalog (English) The SK-H050 features a charge monitor function that measures static elimination Confidential document destruction in new jersey, D157 visa form,, Transcript request form temple university, Publication 901 us tax treaties. Reload to refresh your session. Reload to refresh your session. The HOLD button allows the user to freeze a measurement on the LCD for later review. Ranging System Included with the 3M 718 Static Sensor is a ranging system consisting of two light-emitting diodes (LEDs) which each emit a circular red light onto the surface being measured for static. When the two lights intersect and form a single focused light, the measurement distance is the prescribed 1 inch (2.54 cm). Hand-held static sensor locates and measures static voltages, tests air ionizers. New from 3M, the 718 Static Sensor can help companies competing in the global high-tech marketplace prevent costly losses due to electro static discharge (ESD) damage by playing a vital and valuable role in their own ESD control program. Accuracy will vary as the distance between measured object and instrument changes from the one inch (2.54 cm) specification. The lightweight plastic housing is conductive, allowing a properlygrounded user to dissipate all electrostatic charges from the surface of the meter. LED targets. Aligned targets indicate 1 in. (2.http://www.stolmaster.ru/images/pages/4-speed-manual-transmission.xml54 cm) measurement distance Measurement Accuracy Within 5 of actual voltage Meter Functions The meter is equipped with three membrane switches which control different functions. The POWER switch turns the instrument on and off.The charger can be used to deposit an electrostatic charge on the plate. Measuring how long it takes the ionizer to neutralize this static charge gives the ionizer discharge time. Calibration and Certification The 3M 718 Static Sensor can be ordered as calibrated and certified by a 3M ISO9002 Registered Metrology Laboratory.Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. For more information on the calibration of SCS products, see the Calibration web page. By continuing to browse the site you are agreeing to our use of cookies. Review our Cookies Policy for more information. Otherwise, we’ll assume you’re OK with our use of cookies. Model 718 can also be used to verify the operation of air ionizers when used in conjunction with the 3MTM Model 718A Air Ionizer Test Kit. Select the attributes you require, then click the button below How can I see products similar to this? The sensor's plastic housing is conductive and allows a properly grounded user to dissipate all electrostatic charges from the surface of the meter. A discrete field-sensing element in the front of the unit picks up the static electric field being generated by an electrostatic charge on an object or surface. The unit's internal circuitry then converts this field measurement into the corresponding voltage for that electrostatic charge. The air ionizer test kit is a separate option consisting of a charger plate and charger used with the static sensor to verify air ionizer performance. Learn more. This instrument can play a valuable role in an organization's ESD-control program by helping the user locate and quantify ESD trouble spots.http://www.drupalitalia.org/node/67594Static Sensor, including meter, Operator's Manual, and Certificate of Performance verification. Air ionizers are primarily used to control static charge on nonconductive materials. Grounding is normally used to control charge on conductive objects and personnel; however, nonconductors cannot be grounded to drain electrostatic charge. Ionization is the only method of neutralizing a static charge on a nonconductor. Ionized air can neutralize static charges on circuit board substrates, insulating tapes, and plastic objects found in the work area. 3M offers several models to choose from. Easy to use, the hand-held Static Sensor 718 is designed to measure static voltages on objects and surfaces arising from electrostatic charge buildups, and can help identify ESD trouble-spots helping ensure product reliability and customer satisfaction which translates into company profits. Digital, LCD (liquid-crystal) display is easy to read and updates quickly. Ranging system assists user in making quick and easy measurements. Output jack available for continuous measurements. The lightweight plastic housing is conductive, allowing a properly-grounded user to dissipate all electrostatic charges from the surface of the meter. Meter Functions The meter is equipped with three membrane switches which control different functions. The POWER switch turns the instrument on and off. Ranging System Included with the Static Sensor is a ranging system consisting of two light-emitting diodes (LEDs) which each emit a circular red light onto the surface being measured for static. When the two lights intersect and form a single focused light, the measurement distance is the prescribed 1 inch (2.54 cm). The Static Sensor 718 may then be used for remote monitoring or permanent recording of electrostatic voltage readings. Aligned targets indicate 1 in. (2.54 cm) measurement distance Within 5 of actual voltage UL, C-UL, CE The Air Ionizer Test Kit 718A consists of a charge plate and a charger.http://arma-tek.com/images/3par-f400-service-manual.pdf Placing the Static Sensor 718 in the air flow of an air ionizer allows for measurement of the ionizer's offset balance. The charger can be used to deposit an electrostatic charge on the plate. Charger Weight Charger Power Requirements Charger Output is a trademark of 3M Company. All other trademarks are owned by their respective companies. Important Notice All statements, technical information, and recommendations related to 3M's products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine it is suitable for your intended application. You assume all risks and liability associated with such use. Any statements related to the product which are not contained in 3M's current publications, or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon, in writing, by an authorized officer of 3M. This product will be free from defects in material and manufacture for one year from the time of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above, your exclusive remedy shall be, at 3M's option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except where prohibited by law, 3M will not be liable for any indirect, special, incidental or consequential loss or damage arising from this 3M product, regardless of the legal theory asserted. Please recycle. Printed in USA. 3M 2014. All rights reserved. 78-9102-1667-6 JHA Air ionizers are primarily used to control static charge on nonconductive materials. It is believed to be functioning but we are unable to verify. Therefore we ” The item may have some signs of cosmetic wear, but is fully operational and functions as intended. This item may be a floor model or store return that has been used. See the seller’s listing for full details and description of any imperfections. It is believed to be functioning but we are unable to verify. Therefore we are including a 30 day DOA warranty on it because we are unable to personally test all functions. ”. In addition, DfR determined that these parts had ESD sensitivity as low as 100V, which placed the components under the most sensitive ESD Component Sensitivity Classification of Class 0 ( Upon further research however, it was determined that this option was cost-prohibitive. Therefore, the customer requested that DfR review the contract manufacturer assembly processes in order to identify specific ESD hazard risks so that they could be dealt with on an item-by-item basis. The survey was performed as a team exercise that included the customer’s product and supplier quality engineers and contract manufacturer ESD auditors, quality and process engineers. It also includes an assessment of the facility’s ability to continuously maintain these controls. However, in some situations this was not possible because a specific work site was not operating or was needed during the survey visit. These modifications were made with insulating materials that held a charge and therefore introduced an increased ESD risk.ESD auditors should receive additional training to identify these situations. As a result, our customer found a satisfactory reduction in ESD issues and a corresponding decrease in warranty returns. Te ayudaremos a encontrarlo y ahorraras tiempo. New from 3M, the 718 Static Sensor can help companies competing in the global high-tech marketplace pre vent cost- ly losses due to electro static discharge (ESD) damage by playing a vital and v aluable role in their own ESD control program. The light- weight plastic housing is conducti ve, allowing a properly- grounded user to dissipate all electrostatic charges from the surface of the meter. The PO WER switch turns the instrument on and off. The HOLD b utton allows the user to freeze a measurement on the LCD for later revie w. Accuracy will v ary as the dis- tance between measured object and instrument changes from the one inch (2.54 cm) specification.Por la experiencia de nuestros usuarios sabemos que muchos de vosotros no le habeis dado mucha importancia a este manual. Una gran parte de los manuales de instrucciones se tira a la basura junto con la caja tras su compra. Es un error. Familiarizate con la informacion acerca del manual 3M 718 que te ayudara en el futuro a ahorrar nervios y dolores de cabeza. Solo entonces conseguiras la informacion basica acerca del mantenimiento del producto 3M 718 en un buen estado de explotacion para que pueda sin problemas cumplir su ciclo de vida. Despues, puedes dejar las instrucciones en la estanteria y volver a cogerlas solamente cuando no estes seguro de realizar adecuadamente el mantenimiento del producto. Un mantenimiento apropiado es un elemento necesario para estar contento con 3M 718. Una vez al ano mira en el armario en el que guardas los manuales de instrucciones de todos los dispositivos. Tira los que ya no utilizas. Esto te ayudara a mantener el orden en tu base de instrucciones casera. New from 3M, the 718 Static Sensor can help companies competing in the global high-tech marketplace pre vent cost- ly losses due to electro static discharge (ESD) damage by playing a vital and v aluable role in their own ESD control program. The 718A consists of a char ge plate and a charger.Si pasa algo inesperado durante el uso de 3M 718, tendras todos los documentos necesarios para un arreglo en garantia. En esta parte del manual encontraras informacion acerca de puntos de servicio autorizados de 3M 718 asi como las pistas de como mantener el equipo para no perder la garantia del producto. Aprovecha las pistas del fabricante 3M 718 para poner el producto en marcha adecuadamente sin el innecesario riesgo de danar el equipo. Tambien podras averiguar que piezas o accesorios opcionales para 3M 718 existen y puedes comprar para tu dispositivo. El 90 de los problemas con 3M 718 se repiten para varios usuarios. Leela para utilizar 3M 718 de una manera optima y no gastar mas energia de la necesaria para un funcionamiento adecuado del producto. Sabras que funciones adicionales pueden ayudarte para utilizar 3M 718 de una manera comoda y que funciones de tu dispositivo son optimas para realizar diferentes acciones. Vale la pena familiarizarse con el para evitar decepciones por culpa de un funcionamiento del producto 3M 718 mas corto del esperado. New products are added daily, so check back frequently. We are working diligently to get this fixed. Thank you for your patience. Please Login or Register.We are working diligently to get this fixed. Thank you for your patience. Discover everything Scribd has to offer, including books and audiobooks from major publishers. Start Free Trial Cancel anytime. Report this Document Download Now save Save Static Control Products and Services Catalog-3M For Later 45 views 0 0 upvotes 0 0 downvotes Static Control Products and Services Catalog-3M Uploaded by Vio Chi Description: 3M Static Control Catalog Full description save Save Static Control Products and Services Catalog-3M For Later 0 0 upvotes, Mark this document as useful 0 0 downvotes, Mark this document as not useful Embed Share Print Download Now Jump to Page You are on page 1 of 138 Search inside document Browse Books Site Directory Site Language: English Change Language English Change Language. Interested in? Calibration Repair Equipment Sales Global Services Interested in? Calibration Repair Equipment Sales Global Services All other trademarks are the property of their respective owners. Since we respect your right to privacy, you can choose not to permit data collection from certain types of services. However, not allowing these services may impact your experience. All the items are packaged in a foam-lined carrying case. The meter has separate scales and test settings for measuring surface-to-ground and surface-to-surface resistance at two prescribed test voltages (10V and 100V) and system continuity. Please revise your selection using valid characters only.Simply select your required attributes below and hit the button Please contact customer services. Please contact customer services.Your line note will appear next to that product in your Order Confirmation, Invoice and Dispatch note. Your line note will last for the lifetime of the order only. Please try again.Please try again.In order to navigate out of this carousel please use your heading shortcut key to navigate to the next or previous heading. Register a free business account Please try your search again later.Amazon calculates a product’s star ratings based on a machine learned model instead of a raw data average. The model takes into account factors including the age of a rating, whether the ratings are from verified purchasers, and factors that establish reviewer trustworthiness. This instrument can play a valuable role in an organization's ESD-control program by helping the user locate and quantify ESD trouble-spots. FeaturesBe the first to write a review. User s Guide Any deviation from this intended use could impair the instrument s effectiveness and possibly lead to an unsafe operating condition. The 3M Air Ionizer Test Kit 718A is a set of accessories for use in conjunction with the Static Sensor 718. Their intended use is for verifying the operation of air ionizers by measuring the neutralization time for a static charge placed on a stationary metal plate. Any deviation from this intended use could impair the instrument s effectiveness and possibly lead to an unsafe operating condition. CAUTION The Static Sensor 718 and 3M Charger 718A use 9VDC power supplied by a 9V alkaline battery. Usage of any other power source may cause damage to the instruments. The Static Sensor 718 and Air Ionizer Test Kit 718A have no user-serviceable parts. Do not disassemble the products for any reason.Read and understand all safety information before installing and operating this equipment. 2 4 1.0 Description The 3M Static Sensor 718 is a portable handheld instrument used for locating and measuring electrostatic charges. It can beused to locate ESD trouble-areas, and is a valuable tool for the ESD-control engineer. Used in conjunction with the 3M Air Ionizer Test Kit 718A (available separately), it can be used for verification and auditing of air ionizers.the Static Sensor 718 is battery-powered and has several measurement features: Range: measurements can be taken in a 0-1,990 kv or 19,900 kv range. Automatic Zero: push button feature allows easy adjustment to zero. No screws or dials to turn. HOLD function: allows the User to freeze a displayed measurement, for later evaluation. Automatic shutoff: conserves battery power by shutting off the instrument after 20 minutes of inactivity. 2.0 Power Requirements and Battery Installation 2.1 Both the Static Sensor 718 and 3M Charger 718A use a 9V alkaline battery. 2.2 To install the battery on either unit: Remove the battery cover, located in the lower back of the unit. Once the battery is depleted to approximately 6.5 volts, the instrument will show BAT in the display. At this time, the Static Sensor 718 will not produce accurate results and the battery should be replaced. 2.4 The 3M Charger 718A also has a low battery indicator. This is an LED located at the lefthand side of the unit. When the battery voltage drops below operating level, the LED will light up. At this time, the user shouldreplace the battery. Usage of the Charger 718A under low battery conditions would lead to insufficient voltage levels being generated. 3.0 Operation of the Static Sensor 718 Supplemental notes: For accurate measurements during usage, it is recommended that the outside housing of the Static Sensor 718 be connected to an electrical ground. This can be accomplished by having the user holding the instrument connected to ground through either a static control wrist strap, or while wearing static control footwear. The enclosure of the Static Sensor 718 is made of conductive plastic and is, therefore, electrically connected to whomever is holding the instrument. In addition, ground for the instrument can be provided through the Voltage Monitor Output on the front of the case. 4 6 The 3M Static Sensor 718 is a precision electronic instrument. Improper use or rough treatment can damage the unit, and render it incapable of providing accurate measurements Replace the cover. 2.3 The Static Sensor 718 has a Low Battery indicator. At this time, the Static Sensor 718 will not produce accurate results and the battery should be replaced. 3.1 Turning the unit ON and OFF: To turn on the Static Sensor 718, momentarily press down on the membrane switch labeled POWER. Determining that the power is on can be verified by seeing that the liquid crystal display (LCD) is on, and that the red light-emitting diodes in the front of the sensor are lit. To shut off the Static Sensor 718, momentarily press down on the membrane switch labeled POWER. Determining that the power is off can be verified by seeing that the liquid-crystal display (LCD) is off. 3.2 Making Electrostatic Voltage Measurements: hold the instrument 1-inch (2.54 cm) away from the object being measured. The display will update with the voltage measurement in kilovolts. If the measured voltage is greater than the measurement range of the instrument, a -1. will be displayed. At this time, switch to a greater range. If over-ranging occurs even with the high range activated, the static charge on the object cannot be measured with the Static Sensor Measurement Range: all measurements are in kilovolts (kv) as stated on the front label of the unit. The Static Sensor 718 has two measurement ranges: 0-1,990 kv and 0-19,900 kv. The unit s current measurement range mode can be verified by checking the display. Three digits following the decimal point indicate that the unit is in 0-1,990 kv range. Two digits following the decimal point indicate that the sensor is in 0-19,900 kv range. Simply press the HOLD switch momentarily and the currently displayed voltage will be frozen. A HOLD notice will also be displayed to alert the user that the instrument is currently in HOLD status. To unfreeze the display 5 7 and return to floating measurement, momentarily press the HOLD switch once again. Please note that during HOLD condition the distance indicating LED s are turned off. 3.5 Zero adjustment: the 3M Static Sensor 718 has a zero adjustment function, which sets a zero reference point for all subsequent measurements. After 3 seconds, the display will flash and adjust to zero. Repeat this step for both the low and the high ranges. The zero adjustment should be performed every time the unit is turned on. 3.6 Measurement Accuracy: Distance Indicator: the Static Sensor 718 is factory calibrated to give accurate measurements when it is placed one inch (2.54 cm) away from the object to be measured. To assist the user in gauging this distance, two light-emitting diodes (LED s) are present on the front face of the instrument. These LED s emit two red, bullseye targets on the surface of the object being measured. As the instrument gets closer to the one inch measurement distance, the bullseyes begin to converge. When they converge and become one, the instrument is approximately one inch away, and the measurement can be made. For more accurate measurements, it is recommended that the user manually measure the distance between the front housing of the instrument and the object being measured Accuracy and Size of Object to be Measured: the minimum surface area on an electrostatically charged object which can be accurately measured is a 5 square inch (32.3 cm 2 ) area Measurements from Greater than One Inch (2.54 cm) Away: in the event that a one inch separation between object-to-be measured and the Static Sensor 718 cannot be achieved, it is possible to get approximate readings. Please contact your 3M representative for additional information. 6 8 3.7 Continuous Output: an output jack is provided on the front of the 3M Static Sensor 718. The output signal is dependent on the measurement range currently selected. This is done in order to conserve battery power. In the event that the user needs to have the unit stay ON continuously, when turning the unit on press the POWER AND RANGE switches simultaneously. This deactivates the Automatic Shut-Off feature. The BAT indicator will then flash three times to indicate that the automatic shut-off features has been disabled. The charge plate slides onto the lower groove, on the sides of the Static Sensor Charging the plate: holding the Static Sensor 718 (with charge plate attached) in one hand, use the other hand to touch the probe of the 3M Air Ionizer Test Kit 718A to the charge plate. Be sure to keep the button pressed while removing the probe from the charge plate. If the unit continues to supply an incorrect voltage to the charge plate, please contact 3M for additional instructions. 4.3 Testing ionizer discharge time: after charging the plate, hold the 3M Static Sensor 718 approximately one foot (30.5 cm) away from the ionizer. Monitor the display to see how quickly the 1.1 kv charge is dissipated to 0.1 kv. The speed at which this occurs (the discharge time) indicates how well the ionizer is operating. Please refer to the specific ionizer s operating manual or consult with the ionizer manufacturer to determine what this discharge time should be. Repeat this procedure for both a positively and a negatively charged plate. 4.4 Testing ionizer offset balance: zero the charge plate by touching it with a grounded object. This can either be the finger of a grounded person or some other item which is connected to electrical ground. In either case, zeroing the charge plate should make the display on the Static Sensor 718 read zero. Hold the Static Sensor 718 approximately one foot (30.5 cm) in front of the ionizer. Monitor the display. The value displayed is the offset balance of the ionizer, which is the difference between the number of positive and negative ions being emitted. There are no user-serviceable parts on either product. 8 10 5.2 Calibration: the 3M Static Sensor 718 and 3M Air Ionizer Test Kit 718A products are supplied by the factory pre-calibrated. 3M does not specify a minimum calibration cycle for the Static Sensor 718 or Air Ionizer Test Kit 718A products. The user, usually according to internal Quality procedures, determines calibration cycles. Connectors on the plate with which it can interface with the high voltage power supply. Connections on the metal stand with which it can be connected to electrical ground. 5.5 Procedure: Place the Static Sensor Static Sensor 718 on the metal stand. Verify that it is exactly one inch (2.54 cm) away from the metal plate, and that its position is centered relative to the plate Connect the stand to ground Turn on the Static Sensor 718 and set it to the low range Ground the plate. Zero the display Remove the ground from the plate, and connect it to the high voltage power supply. Apply a 1 kv charge to the plate. 9 11 5.5.6 The instrument should now be reading If it is not, remove the battery door and use a screwdriver to turn the small screw located inside the battery compartment. Use a small screwdriver to turn the small screw, located on the front right side of the instrument. This screw should adjust the reading on the display. Charge Plate Assembly 718A 1 ea. The mark indicates the requirement NOT to dispose the equipment as unsorted municipal waste, but use the return and collection systems according to local law. Caution To reduce the risks associated with environmental contamination: Dispose of the monitor and power adapter in accordance with local, state, and federal regulations.FCC This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Restriction of the use of certain hazardous substances (RoHS): Meets EU Directive. 12 14 UL Listed to U.S. and Canadian Safety Standards. Important Notice All statements, technical information, and recommendations related to 3M s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended application.